Фрагмент инструкции


Check to make sure the Water Drain Valve (10A) is fully closed. (See Assy. Diagram A.) 2. Turn the Air Flow Valve (6A) to its “OFF” position. (See Assy. Diagram A.) 3. Connect the air hose (not provided) to the Air Flow Valve (6A) of the Air Compressor. Then, connect the other end of the air hose to the pneumatic tool (not provided) that is to be used. (See Assy. Diagram A.) 4. Note: Always plug the Power Cord of the Air Compressor into a 115V electrical source (±10% maximum variation). 5. Pull up on the “ON/OFF” Power Switch (1A) to turn the Air Compressor on. (Push down on the “ON/OFF” Power Switch to turn the Air Compressor off.) (See Assy. Diagram A.) 6. Allow sufficient time for the Tank Pressure Gauge (4A) to indicate 80 PSI before using the Air Compressor. (See Assy. Diagram A.) 7. Turn the Air Flow Valve (6A) to its “ON” position to allow air to the pneumatic tool. (See Assy. Diagram A.) REV 11/04 SKU 47065 For technical questions, please call 1-800-444-3353. PAGE 6 8. NOTE: With the Air Compressor turned on, the operation is automatic and under the control of the automatic switches inside the box under the Power Switch (1A). NEVER open the power switch box or adjust the controls within. To AdjustThe Air OutputToThe PneumaticTool: 1. NOTE: When adjusting the air pressure being forwarded to the pneumatic tool, you will need to compare the pressure readings of both the Tank Pressure Gauge (3A) and the Tool Pressure Gauge (4A). The reading on the Tank Pressure Gauge dictates the maximum/minimum air pressure at which the Tool Pressure Gauge may also be set. (See Assy. Diagram A.) 2. With the Air Compressor running, and the air hose and pneumatic tool hooked up to the Air Compressor, pull up on the Tool Pressure Adjuster (2A). Turn the Tool Pressure Adjuster clockwise to increase the air output to the tool, up to the working air pressure (115 PSI) as indicated on the Tank Pressure Gauge (3A). (See Assy. Diagram A.) 3. Turn the Tool Pressure Adjuster (2A) counterclockwise to decrease the air output to the tool, down to the minimum rated pressure (0 PSI) as indicated on the Tank Pressure Gauge (3A). (See Assy. Diagram.) To UseTheTank Pressure ReliefValve: 1. The Tank Pressure Relief Valve Ring (5A) is used when decompression is needed quickly and efficiently. (See Assy. Diagram A.) 2. To decompress the Air Tank (9A) pressure, press the “ON/OFF” Power Switch (1A) down to turn off the Air Compressor. (See Assy. Diagram A.) 3. Pull out on the Tank Pressure Relief Valve Ring (5A) to immediately release air pressure in the Air Tank (9A). (See Assy. Diagram A.) To Empty Air And Condensation FromTheTank: 1. The Water Drain Valve (10A) is located underneath the Air Tank (9A), and should be used daily to release all trapped moisture through this valve. The Water Drain Valve will also eliminate condensation that may cause Air Tank corrosion. (See Assy. Diagram A.) 2. WARNING: Do not open the Water Drain Valve (10A) so that more than four threads are showing. 3. Push down on the “ON/OFF” Power Switch (1A) to turn off the Air Compressor. Then, unplug the Air Compressor’s Power Cord from the electrical outlet. (See Assy. Diagram A.) 4. Slowly and carefully unscrew (no more than four threads) the Water Drain Valve (10A) until the compressed air and condensation begins to be released from the Air Tank (9A). Allow sufficient time for all of the air and condensation to escape from the Air Tank. Then, firmly retighten the Water Drain Valve. (See Assy. Diagram A.) REV 01/05; 08/05 SKU 47065 For technical questions, please call 1-800-444-3353. PAGE 7 Reference: Overload Switch (#35B) The overload breaker will trip if an over-current condition is sensed, stopping the motor. If this occurs, shut off the pressure switch and wait at least 5 minutes. Release the air pressure in the tank to ease restarting. Then press the breaker button to reset it, and turn on the pressure switch. Reference: Overload Switch (#35B) The overload breaker will trip if an over-current condition is sensed, stopping the motor. If this occurs, shut off the pressure switch and wait at least 5 minutes. Release the air pressure in the tank to ease restarting. Then press the breaker button to reset it, and turn on the pressure switch. 1. CAUTION: Always disconnect the Air Compressor from its electrical supply source before performing any inspection, maintenance, or cleaning. 2. BEFORE EACH USE, inspect the general condition of the Air Compressor. Check all air fittings for leaks. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged power cord and plug, and any other condition that may affect the safe operation of this tool. If abnormal noise or vibration occurs, immediately disconnect the Air Compressor from its electrical supply source and have the problem corrected before further use. Do not use damaged equipment. 3. DAILY: Check the Air Compressor oil level. If necessary, fill with a premium quality, 30-weight, ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории