Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Yamaha, модель M2500-40C

Производитель: Yamaha
Размер: 1.65 mb
Название файла:
Язык инструкции:enfrde
Перейти к скачиванию



Фрагмент инструкции


Utility items The items that can be selected in Utility mode and their values are as follows. Utility items Values (battery check) ........................................... *.* (*.* is the voltage value) This shows the voltage of the internal battery. If one of the following displays appears, please contact your dealer to have the battery replaced or service performed. • If instead of “ ” the display alternately shows “ ” and the voltage value This indicates that the voltage of the internal battery is lower than 2.5 V. • If instead of “ ” the display alternately shows “ ” and “ ” An abnormal voltage has occurred. (memory protect)................................on/oFF (factory setting: “ ”) This is a function that prevents important scene memories from being erased accidentally. If this is on (on), it will not be possible to store scenes. Also, the contents of scene memory will not be rewritten even if a bulk dump is received from the MIDI IN connector. (recall operation) ...............................dir/GrP (factory setting: “ ”) Specify the function of the DIRECT RECALL 1–8 switches. • If “ ” is selected These switches will function as direct recall switches to directly recall scene memory numbers 1–8. • If “ ” is selected These switches will function as mute group switches to add/cancel mute groups 1–8. (For details on mute groups, refer to page 37.) (memory initialize)........................ALL/1–128 This function erases scene memories. Specify the value and press the STORE key to erase the scene memory. • If “ ” is selected All scene memories (1–128) will be erased. • If “ ”–“ ” is selected The scene memory of the corresponding number (1– 128) will be erased. Note: • It is not possible to recover a scene memory that has been erased. • If the “ ” (memory protect) item is on, the memory initialize function cannot be executed. 34 M2500—Owner’s Manual The Scene Memory function The Scene Memory function (MIDI channel) ....................................... 1–16 (factory setting: “ ”) Select the MIDI channel that will be used when MIDI data is transmitted/received via the MIDI IN/OUT connectors. (program change transmission/reception) ... ....oFF/on/LoC (factory setting: “ ”) This specifies whether or not program change messages will be transmitted/received via the MIDI IN/ OUT connectors. • If “ ” is selected Program changes will not be transmitted or received. • If “ ” is selected Program changes will be transmitted and received. – When program changes 0–127 are received at the MIDI IN connector, scene memory numbers 1–128 will be recalled. (However if the utility item “Recall operation” is set to “ ,” program changes 0–7 will be ignored.) – When you recall a scene memory number 1–128 in which a scene has been stored, a program change 0–127 will be transmitted from the MIDI OUT connector. (Even if the Utility item “Recall Operation” is set to “ ,” you can use the 0–9/ENTER and RECALL switches to transmit program changes 0–7 from the MIDI OUT connector.) • If “ ” is selected Program changes will be transmitted and received. – Program changes will be received in the same way as for the “ ” setting. – Even when you recall a scene memory number 1– 128 in which no scene has been stored, a program change 0–127 will be transmitted from the MIDI OUT connector. (control change transmission/reception)...... ....oFF/GrP/on (factory setting: “ ”) Specify whether control change messages will be transmitted/received via the MIDI IN/OUT connectors. • If “ ” is selected Control change messages will not be transmitted or received. • If “ ” is selected Control change messages will be transmitted and received. – When control change numbers 1–70 are received, the corresponding channel will be switched on/off. When mute groups are used, control change numbers 105–112 will switch mute groups 1–8 on/off. (For details refer to the following section “Control change table.”) • If “ ” is selected Only the control change numbers (105–112) that correspond to mute groups 1–8 will be transmitted and received. (program change reception omni on/off)..... .............on/oFF (factory setting: “ ”) Specify whether or not the MIDI channel specified by the Utility item CH will be used when receiving program change messages. • If “ ” is selected Program change messages will be received on all MIDI channels (1–16). • If “ ” is selected Program change messages will be received only on the MIDI channel specified by the Utility item CH. (echo back)..........................................on/oFF (factory setting: “ ”) Specify whether messages received at the MIDI IN connector will be echoed back from the MIDI OUT connector. If this is turned “ ,” messages will be echoed back. However if a bulk dump request is received, that message itself will not be echoed; rather, the bulk dump data will be transmitted. (bulk out).......................................ALL/1–128 Transmit the contents of scene memory from the MIDI OUT connector as MIDI bulk d...

Эта инструкция также подходит к моделям:
Музыкальные инструменты - M2500-24 (1.65 mb)
Музыкальные инструменты - M2500-32 (1.65 mb)
Музыкальные инструменты - M2500-48C (1.65 mb)
Музыкальные инструменты - M2500-56C (1.65 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории