Фрагмент инструкции
Doing otherwise may void the warranty. Any changes made to the equipment without authorization from the factory will void the warranty. PREPARATION .. Check the integrity of the unit once it is unpacked. .. Check to make sure the floor is level. .. Check that the available power supply (Voltage, # of phases, Hz, Amps, max. fuse size) corresponds to the ratings on the nameplate and that correctly rated electrical protection is provided (VOLTAGE MUST BE WITHIN ± 5% FROM THE NAMEPLATE VALUE). .. Make certain that adequate drainage is provided. D.1. Blast Chilling Modes AP40BC250-12, AP40BC250-2-12, BCCP-1, BCCP-2, and BCIP are equipped with a high versatility electronic controller allowing the chef to choose between automatic and manual operation. Automatic Mode In the first part of the cycle the air temperature is lowered to a preset temperature (100F). When the food core temperature reaches a preset breaking temperature point (600F) the unit will switch to the second part of the cycle which is design to protect the food from getting frozen. The air temperature will rise to a preset temperature range (280F to 350F). The chilling cycle is complete when the food core temperature reaches the desired end temperature (400F). Manual Mode In the manual mode the blast chilling operation will last for a preset time. In the first part of the manual cycle the air temperature is lowered and held to a preset temperature (100F). Once the time for the first part of the cycle expires the unit will switch to the second part of the cycle. The air temperature is held at a preset temperature range (280F to 350F) for the remaining time (1 hour). Note: At the end of any blast chilling cycle the unit will automatically switch to a holding mode which will keep the food at 380F until START/STOP button is pressed to end the cycle. D.2. PC Connection Mode The unit can be programmed and operated from a remote PC via modem and software (Windows 95, 98, 2000, NT, and XP). Maximum distance is 4000 feet. Full instructions are supplied on a computer disc, which is furnished when the computer connection is ordered. All connections should be made exactly as shown in the connection diagram, drawing number 98002-01B on page 38 of this manual. The application allows the operator to save the programmed parameters and the events memory to PC for archival purposes. The software’s interface emulates the control panel. D.3. Programming Modes All American Panel Corporation blast chillers are initially programmed at the factory. These settings may be considered standard for AP40BC250-12, AP40BC250-2-12, BCCP-1, BCCP-2, and BCIP units. However, the customer may change any of these settings as indicated by necessity. There are two programming modes to be covered: Initial Programming - settings like year, month, date, time, and several other parameters. Parameter Programming - settings that control the chilling cycles. To program the controller the customer can either use the control panel at the unit, or the PC application. The front panel buttons are divided into 3 groups, as follows: 1. 3. On/Off Select Start/Stop Up 2. Down Automatic Cycle Manual Cycle Enter Defrost Cycle UV Cycle Print D.4. Initial Programming The initial configuration of the system can be performed in Initial Programming mode. This includes setting the current year, month, date and time, as well as several other parameters. Note: During the programming steps, any delay longer than 20 seconds before pushing the next button will cause the controller to revert to “OFF” state and the display will show: OFF. TO AVOID THIS, THE FOLLOWING INSTRUCTIONS SHOULD BE CAREFULLY REVIEWED AND THE DESIRED SETTINGS SHOULD BE DETERMINED BEFORE PROCEEDING. If the control panel goes to OFF state, programming mode will have to be restarted. Note: During programming, pressing and holding or button for more than two seconds will increase the value changing speed. D.4.1. Initial Programming Procedure And Parameters The instructions below contain screens with the exact messages displayed by the controller during programming procedure. Follow the notes located to the right of these screens. Check that the unit is plugged in and power is available. The controller should be in OFF state. If it is not, press . Press and hold for approximately 5 seconds. When the command is accepted, the controller will give one long beep and ask the operator to select the desired language. Use and buttons to scroll thru the language settings. Press when done. The controller will ask the operator to enter the access code. Press, in order and within 20 seconds, the following combination ..... When done, confirm by pressing . Note: If the entered access code is not correct, the controller will ask the operator to re-enter the code. Wait five seconds and then re-enter the access code. If the correct code is entered, the controller will give a short beep and display the message: To skip press . To change the access code press, in orde...
Эта инструкция также подходит к моделям:Морозильные камеры - Blast Chiller BCCP-1 (2.17 mb)
Морозильные камеры - Blast Chiller AP40BC250-12 (2.17 mb)
Морозильные камеры - Blast Chiller BCCP-2 (2.17 mb)
Морозильные камеры - Blast Chiller BCIP (2.17 mb)