Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации John Deere, модель HR-2500GH

Производитель: John Deere
Размер: 10.14 mb
Название файла: press_wash_d.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


Check proper level. . Place unit on level surface. 2. Remove oil filler cap/dipstick (A) and wipe it clean. 3. Insert filler cap/dipstick into oil filler neck, but DO NOT screw it in. 4. Remove dipstick. Proper oil level is at midpoint of dipstick (A). Add oil if necessary to bring oil level to top of threads (B). 5. Install and tighten cap. a P04-0 07 b sae 5W-30 P05-0 07 gasOline engine Oil Use oil viscosity based on the expected air temperature 50°C 122°f range during the period between oil changes. 40°C 104°f John Deere TURF-GARDTM is preferred. Also recommended is John Deere PLUS-4®. 86°f 30°C Other oils may be used if they meet one or more of the following: sae 10W-40 sae 10W-30 68°f 20°C •API Service Classification SH •API Service Classification SG 50°f 10°C •CCMC Specification G4 32°f 0°C •CCMC Specification G5 14°f -10°C -4°f -20°C -22°f -30°C -40°f -40°C DWG - 0 99R0 AC-Series Operator’s Manual-E/F Preparing the Washer filling fuel Tank CAUTION: Risk of fire. Handle fuel carefully. -Do not add fuel when product is operating. Stop engine and allow engine to cool for two minutes before refueling. Hot surfaces can cause burns and ignite spilled fuel. Do not touch muffler. -Fill fuel tank outdoors away from flames and open sparks. -Do not smoke when filling fuel tank. -Do not overfill fuel tank. (There should be no fuel in filler neck.) -Avoid spilling fuel. Wipe clean after refueling. -Move from refueling area before starting. -Prevent fires by keeping engine clean of accumulation, grease, trash and debris. iMPOrTanT: do not permit dirt or other foreign matter to enter the fuel system. This will cause hard starting, poor performance and engine damage. Always use clean fuel storage containers and funnels. Use clean, fresh, lead-free gasoline. Do not use stale gasoline or gasoline that has been stored for a long time. Stale gasoline does not vaporize properly, causing hard starts. Use of TY 5977 gasoline stabilizer is highly recommended . Use of leaded gasoline or gasohol is NOT recommended. IMPORTANT: Do not mix oil with gasoline. . Wipe dust and dirt from around fuel tank. Remove filler cap (A) and place cap in a clean area away from muffler. 2. Slowly fill the fuel tank to bottom of filler neck with lead free gasoline. Do not overfill, leave approximately 5mm (0. 9 in.) of open space at the top of the tank for fuel expansion. 3. Replace and tighten filler cap. fuel Tank Capacity HR- 500GH, HR- 700GH ............ .7 L (0.46 gal) a AC-Series Operator’s Manual-E/F Preparing the Washer inleT WaTer suPPly requireMenTs . Inlet water supply must be a minimum of 0 PSI ( .4 bar). Attempting to operate the washer with less than adequate water supply will cause rapid wear of packings, valves and bearings that will dramatically shorten pump life. Symptoms of inadequate water supply are pump shuddering and flattening of the supply hose. 2. Inlet water flow must be at least 125% of pump rated flow (see table below). Check volume by timing how long it takes to fill a 5 gallon (19 L) container. For example, a flow rate of 3.0 GPM would fill a 5 gallon container in 5/ minute ( 00 seconds). . Water supply hose should be a good grade of garden hose with a minimum I.D. 5/8 in. ( 6mm) and no longer than 50 ft. ( 5. 4 m). If longer supply hose must be used, check to be certain flow is at least equal to the “GPM Supply Required” value listed at the bottom of this page for your washer. 4. If non-pressurized (static draw) water supply is used, check to be certain flow is at least 125% of pump rated flow (see table below). In static draw situations, water flow rate (GPM) can be increased by elevating the water supply tank or changing to a larger inside diameter water supply hose. 5. Adding on extension to the supply hose will reduce water flow rates. Check for adequate water flow rate each time an extension is added. Water flow rates can be increased by using the largest possible internal diameter supply hose. iMPOrTanT: inlet water temperature must not be more than 125° F (60° C). Damage to the pump may result. Washer Rated Flow GPM Supply (GPM) Required HR- 500GH............... . ............................ HR- 700GH............... . ............................ PIC4-09 99R0 4 AC-Series Operator’s Manual-E/F Preparing the Washer PuMP Oil This pump does not require periodic changing of the oil. It uses a high grade synthetic oil which will last for the life of the pump. P07-0 07 COnneCT hOses and PriMe PuMP IMPORTANT: Besurethatinletwaterscreen(C)iscleanandin place before connecting water supply hose to washers. The water pump and valves could be damaged from contaminants. NOTE: Filling supply hose with water before attaching to pump will greatly reduce priming time. . Prime water supply hose. Shut off water. . Connect water supply hose to washer inlet (B). Be sure water supply and hose meet specifications. Do not turn water on at this time. CauTiOn: Check pressure rating printed on the hose. Use proper hoses. . Connect hi...

Эта инструкция также подходит к моделям:
Моечное оборудование - HR-2700GH (10.14 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории