|
Фрагмент инструкции
The operation of the unit by remote control, is almost identical to the operation by the circular control panel. The only exception is the clock function. Instead of the button for setting the actual time and for programming the timer, there are 3 push buttons on the remote control as follows: • - for setting the actual time. • TIMER ON - for programming the time when the unit is ON. • TIMER OFF - for programming the time when the unit is OFF. EMPTYING THE INTERNAL WATER CONTAINER Under high humidity conditions it may be necessary to empty the internal water container. When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically. To empty the water container do the following: • Switch off the unit and remove the plug from the wall socket. Do not move the unit. Doing this can result in water leakage, damaging your floor or carpet. • Place the water container on the floor underneath the permanent drainage point. • Remove the water stopper and rubber plug from the drain and let the water run out. The water container has to be emptied several times before all water will be drained (ca. 1.5 litres). • Replace the rubber plug and water stopper, put the plug into the wall socket, and switch the unit on. The warning signal should be off. NOTE! When the air conditioner is in use, under normal circumstances the condensed water will evaporate and then be discharged through the hot air outlet hose 9 CLEANING CLEANING WARNING! First of all switch off the unit and remove the plug from the wall socket. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Clean the screen filter regularly with a vacuum cleaner. See also “air filter” section. NOTE! Never use the air conditioner without the screen filter. TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property. Problem Cause Solution The air conditioner does not function. No power supply. Connect to a functioning outlet and switch on. Is the LCD light flashing. Empty the internal water container. Timer function is active. Deactivate TIMER function. The air conditioner does not seem to perform. In direct sunlight. Close curtains. Windows or doors open, many people or a heat source in the room. Close doors and windows, place an extra air conditioner. Dirty filter. Clean or replace the filter(s). Air inlet or air outlet blocked. Remove the blockage. Room temperature lower than the selected value. Change temperature selection. The unit is noisy. Unit stands uneven. Place on an even, solid surface (less vibrations). The compressor does not work. The overheat protection is probably activated. Wait 3 minutes until the temperature has decreased, then turn on the unit again. The remote control does not function. Distance too great. Make sure the remote control is correctly aimed at the control panel.Remote control signal not detected by the control panel. The batteries are drained. Replace the batteries. To correct problems that have not been described in the table and/or if the recommended solutions fail to solve the problem, contact an authorized service centre. 10 1010 STORAGE STORAGE Empty the internal water container. Clean the screen filter. Remove 3M Filtrete™ filter and active carbon filter. • Remove the 3M Filtrete™ filter and active carbon filter before end of season storage and install new filters at the beginning of the new season. The old filters can be disposed of in the ‘Non-biological rubbish container’. • Replacement filter packages are available from Amcor. Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry. Store the cable as shown. Protect the unit against dust and store in a dry place, not accessible to children. TECHNICAL DATA Model9000E12000E15000E9000EH12000EH15000EHCooling capacity * BTU/h 7000 9000 12000 kW 2 2.6 3.5 Power consumption -Cooling -Heating (EH only) 880 1100 1330 W 1700 1600 A 4 5 6 R407C / 570 R407C / 650 -heating element (EH only) Current -Cooling 7.5-Heating (EH only) Mains V / Hz / PH 220 -240 / 50 / 1 Compressor model rotary Fan speeds 3 (2+1 turbo) Thermostatic range °C 18 -32 Refrigerant charge type / g R407C / 480 Dimensions (w x h x d) mm 555 x 800 x 455 Net weight kg 31.5 34 39 * measured conform EN 14511. Subject to modifications without prior notice. For greater precision, please refer to the rating label placed on the product. Reminder: Waste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. 11 YOUR GUARANTEE DOMESTIC AIR CONDITIONERS If this product is found to be defective as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge. This guarantee is subject to the following term...
Эта инструкция также подходит к моделям:Кондиционеры - 12000E (804.93 kb)
Кондиционеры - 9000E (804.93 kb)