Войти:
Оценок - 4, средний балл: 4.5 ( )

Инструкция по эксплуатации Amcor, модель 12000E

Производитель: Amcor
Размер: 804.93 kb
Название файла: a1206b39-0d65-472d-81f7-2ea32a4b15ae.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Perform the standard steps as described above. • Repeat the above procedure while the digits are still flashing for setting the ON. The circular time scale will be ON between 00:00 to the time set with the timer to OFF and from that time until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes. The unit will operate daily according to the timer setting. Repeat ON and OFF Programming the timer for repeat ON and OFF - when the unit is NOT RUNNING. • Perform the standard steps as described above. • Repeat the above procedure while the digits are still flashing for setting the OFF. The circular time scale will be OFF between 00:00 to the time set with the timer to ON and from that time until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes. The unit will operate daily according to the timer setting. After a power failure, or after the unit has been unplugged, you will have to program the timer settings again. Cancelling the timer function In order to cancel the timer programming press the button momentarily, then it will return to the time display. The daily mode will be cancelled as well. The black segments in the circular time scale will disappear. Air flow Direct the air flow by adjusting the grill on top of the air conditioner. Move the grill, by pushing or pulling, in the middle (see illustration). This will avoid uneven positioning of the grill. Adjusting the air flow is also possible by moving the direction of the vertical louvers. Sleep mode The sleep mode function adjusts the set temperature of the unit to the thermal needs of the body falling asleep as follow: • In the COOL or AUTO COOL mode • Default fan speed: LOW • Press the button to operate the sleep mode. Press the button again in order to cancel the sleep mode. The set temperature will increase 1°C after 1 hour and a further 1°C after 2 hours. • No FAN mode under SLEEP mode operation Dehumidification If the unit will be used mainly as a dehumidifier just let the warm air return in the room. Continuous drainage is then necessary and more efficient. For continuous drainage: • Switch off the unit and remove the plug from the mains. • Remove the water stopper and rubber plug. • Connect a drain tube (o 20 mm inner dimension) onto the water outlet and extend with extra water tube if needed. • Place the other end in a normal drain. Make sure that the tube is free from twists and bends. The tube must decline over its entire length. AIR FILTER This air conditioner can be equipped with a 3-layer filter to clean the circulated room air. a. Screen filter; to remove bigger dust particles. b. All models: active carbon filter; to remove odours. c. 3M Filtrete™ filter; to remove unhealthy particles from the air such as pollen, bacteria, animal dander and dust. Selected models have the 3M Filtrete™ filter as standard. However, if you require to add this to your model, or wish to purchase a replacement, call Amcor for details. NOTE! The active carbon filter and the 3M Filtrete™ filter are delivered in a plastic packaging. Don’t forget to install these filters. These filters take away unhealthy particles out of the room environment. The filter holder on the rear of the unit can be opened. The active carbon filter and 3M Filtrete™ filter can be installed or removed. The screen filter is part of the filter holder (see illustration). a. The screen filter has to be cleaned regularly with a vacuum cleaner to avoid blocking of the air flow. b. The positive/negative electrostatically charged 3M Filtrete™ filter is recommended to be changed every 3 months. Unusual dirt, construction work, pets, the presence of smoke and running the air conditioning unit continuously can shorten the life time of the 3M Filtrete™ filter. c. The active carbon filter can be cleaned with a vacuum cleaner when dusty but has to be changed at the same time as the 3M Filtrete™ filter. Filter installation 1 2 3 4 • Slide out the filter holder from the unit. • Separate the filter fixer from the filter holder (see fig. 1). 8 88 • Remove the active carbon filter (black) and the 3M Filtrete™ filter (white) from its plastic bag. • Insert the active carbon filter into the filter holder (see fig. 2). • Insert the 3M Filtrete™ filter into the filter holder (see fig. 3). • Fix the filter by reassembling the fixer into the filter holder (see fig. 4). NOTE! • Remove the 3M Filtrete™ filter and active carbon filter before seasonal storage and install new filters at the beginning of the new season. The old filters can be disposed in the ‘Non-biological garbage container’. • Replacement filter packages are available directly from Amcor. • To run the unit without active carbon filter and/or 3M Filtrete™ filter does not do any harm to the air conditioner. In this case odours and unhealthy dust are not removed from the circulated air. • The screen filter must always be used. • 3M and Filtrete are...

Эта инструкция также подходит к моделям:
Кондиционеры - 9000E (804.93 kb)
Кондиционеры - 15000E (804.93 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории