Войти:
Оценок - 4, средний балл: 3 ( )

Инструкция по эксплуатации CMS Products, модель 674

Производитель: CMS Products
Размер: 3.29 mb
Название файла: 6740001.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This time and the normal coffee settings will compute the new cappuccino time. (This is a handy way to move from one selection to another without going to the SETUP screen first.) If you try to set up a selection that is not configured, the SETUP screen will remain in the display. OPTIONS: i. At any of the preceding displays, you can press to test throw that item. ii. At any of the preceding displays, you can press * or # (on the selection switch panel) to step through a list of that item’s throw times for other selections where that item is active. For example, pressing # at the WAT. A display will show the throw time for WAT. B. This is a handy way to move from one selection to another without going to the SETUP screen first. NOTE If you try to set up a selection that is not configured, the SETUP screen will remain in the display. e. Continue. 6740001 50 November, 2007 HotCup Operators’ Guide Hot Drink Setup VIEW OR SET THE HOT WATER TANK TEMPERATURE a. Press then until the display shows SET 202 °F . In this example, 202° is the water tank temperature setpoint in degrees Fahrenheit. If a decimal point appears next to the “F”, the heater is on. b. If desired, enter a new setpoint in the accepted range of 149° - 205° F (65° - 96° C). NOTE The lower limit for vending is 20° below setpoint, up to a maximum of 180° F (82° C). c. To change display units (replace the “F” with a “C” for Celsius), press . d. Continue. SET UP LOW TEMPERATURE DISPENSING a. Press then press until the screen displays either: LTDIS off. This causes the machine to operate the same as the previous HotCup Center. For example, with a setpoint temperature of 202. F the machine will inhibit vending when the water tank temperature reaches 182. F. -or ltdis on. Allows vending to a water tank temperature of 140. F. b. Press to change between ON and OFF. c. Continue. November, 2007 51 6740001 Hot Drink Setup HotCup Operators’ Guide SET UP LOW POWER SETTINGS Low power settings allow for the water tank to be set to a lower temperature at up to 4 different dates and times. For example, you want to lower the tank temperature to 160. F overnight on Mondays through Fridays. The machine tank temperature setpoint will be changed to 160. F at 6:00 pm and maintained at that temperature until 5:00 am on the following morning when the setpoint is returned to 202. F. Please keep in mind that at 5:00, the machine will just begin to increase to the 202. F setpoint temperature. It is up to you to determine how long that will take and to allow enough time for the tank to be at its proper temperature when the machine will be used. Typically, one hour is adequate to return to the normal operating temperature. NOTE: The machine OUT OF SERVICE condition during the low power interval will be determined by how you have set the LTDIS configuration. a. Press then press until the screen displays LOW.PWR. b. Press the number of the time interval you want to edit, or to edit time interval 1( we will use interval 1 for this example. c. The display shows low.pw ON or low.pw Off. This display tells you whether your time interval (represented by 1) is on or off. Press to change the condition of the time interval. d. If you turn an interval ON, it must be edited. You can edit a time interval now, then turn it OFF until another time. e. Press . The display shows 1.STRT X.XX.. X.XX is the currently set start time. Enter a new start time (24-hour format) for this interval. To enter the time for 6:00 pm, enter 1800. . The display shows 1.STOP X.XX.. X.XX is the currently set stop time. Enter a new stop time (24-hour format) for this interval. To enter the time for 5:00 am, enter 0500. f. Press g. Press . The display shows 1.@ - - - - - - -. The dashes represent the days that this time interval is active. Pressing number keys 1 through 7 switches the days on/off. For example, press “2”, “3”, “4”, “5”, and “6”. The display now shows 1.@ - M t W t F -. This interval is active on Monday through Friday. 6740001 52 November, 2007 HotCup Operators’ Guide Hot Drink Setup (Square) SET THE BREWER RINSE TIME INTERVAL a. Press , then press until the display shows SAN.TIM X.X. "X.X" represents the time of day (in hours and tenths of hours) the machine rinses the brewer. For example, SAN.TIM 4.5 means that brewer rinse takes place at 4:30 am. Use the number keys to enter a new time, if desired. Range: 0.0 - 23.9 in .1 hour (6 minutes) increments. b. Press . The display shows SAN.HRS X.X. "X.X" represents how soon the machine rinses the brewer after the last brewed selection. For example, SAN.HRS 2.5 means brewer rinse takes place 2.5 hours after the last vend. Use the number keys to enter a new time, if desired. Range: 2.0 - 12.5 hours, in .1 hour (6 minutes) increments. c. CONTINUE. November, 2007 53 6740001 Hot Drink Setup HotCup Operators’ Guide SET THE BOWL RINSE TIME Mixing bowl(s) can be automatically rinsed by one of two methods: You can specify a set time of day when the bowl is rinsed, ...

Эта инструкция также подходит к моделям:
Кофеварки - 676 (3.29 mb)
Кофеварки - 674 (3.29 mb)
Кофеварки - 676 (3.29 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории