7. Remove glass door before lighting pilot. (See Glass Frame Removal section). 8. Visibly locate pilot by the main burner. 9. Turn knob on gas control counterclockwise to "PILOT". • If knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier. 11. Replace glass door. 12. Turn gas control knob to “ON” position. 13.

Скачали: 2   Размер: 2 mb   Производитель: CFM Corporation  
Категория: Камины
@name

FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas suppler. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS

Скачали: 0   Размер: 167 kb   Производитель: CFM Corporation  
Категория: Камины
@name

Min inlet pressure : 5 11 in w.c. Max inlet pressure : 7 14 in w.c. Vent size : 4” Diam. listed gas liner Valve : Natural gas Propane White Rogers Robertshaw Model 36C03U TYPE 139 Model 7000 MVRLC Millivolt operated Millivolt operated SIT SIT Nova model Nova model Millivolt operated Millivolt operated Blower : Variable speed, 140 CFM Thermo-switch : 120° F “ON” 110° F “OFF” bi-metal type Efficiency : 74% heating Clearances to combustibles : mantel : 10” from top of face place side wall : 0” from

Скачали: 0   Размер: 167 kb   Производитель: CFM Corporation  
Категория: Камины
@name

* The glass used on your fireplace is a high temperature ceramic 5 mm thick with a special coating for use with gaseous fuels. Do not replace it with any other material. CAUTION : Do not operate your fireplace without a glass or with a broken glass. BURNER REMOVAL AND INSTALLATION : REMOVAL : 1. Slide the burner to the left and pull toward you. 2. To gain access to the fan, also remove the firebox bottom plate. INSTALLATION : 1. Put the bottom plate back in place. 2. Put the burner assembly back

Скачали: 0   Размер: 2 mb   Производитель: CFM Corporation  
Категория: Камины
@name

sembly. adjustment knob located near the center of the gas control. (Figs. 19 or 20) ........ Turn counterclockwise to decrease flame height Turn clockwise to increase flame height Honeywell Valve 12 10002964 Gas Fireplace Insert First FiringFlame Characteristics It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the Figure 21 and Figure 22 or 23. If any of the flames appear abnormal call a service person. 10002964 pears within a few minute

Скачали: 4   Размер: 2 mb   Производитель: CFM Corporation  
Категория: Камины
@name

WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from your neighbor’s phone. Follow the gas suppliers instructions. • If you cannot reach your gas supplier call the fire department. FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier. Gas Fireplace Insert Models: A125 A132 Homeowner’s Installation and

Скачали: 2   Размер: 284 kb   Производитель: CFM Corporation  
Категория: Камины
@name

If you are using a factory built chimney, it must comply with UL 103 or ULC S629 standards; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer's specifications. If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the National Building Code. It must be lined with fire clay bricks, metal or clay tiles sealed together with fire cement. (Round flues are the most efficient). Th

Скачали: 0   Размер: 480 kb   Производитель: CFM Corporation  
Категория: Камины
@name

(Fig. 1) Ensure the left door is installed on the left and right door is installed on the right. 4. Re-install top louvre assembly. Instructions (Black), GASS4S0 (Pewter) (Black), GAHJ4S0 (Black) Figure 1 20013452 3/08 Rev. 1 4 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Arch Screen Door Kit Models: GABS4S0, GASS4S0, GAHR4S0, GAHJ4S0 Ref. Description GABS4S0 Black GASS4

Скачали: 0   Размер: 480 kb   Производитель: CFM Corporation  
Категория: Камины
@name

(Operating without glass frame in place could cause carbon monoxide (CO) to spill into the room.) CAUTION: Allow unit to cool completely if it has been in operation. Kit Contents: • Screen Door Assembly, left • Screen Door Assembly, right • Arch Frame • Installation Instructions Installation Instructions NOTE: Remove all plastic from packaging. 1. Remove existing top louvre from fireplace by lifting up and pulling out (Refer to top louvre instruction manual for details). 2. Hang arch f

Скачали: 4   Размер: 480 kb   Производитель: CFM Corporation  
Категория: Камины
@name

(Operating without glass frame in place could cause carbon monoxide (CO) to spill into the room.) CAUTION: Allow unit to cool completely if it has been in operation. Kit Contents: • Screen Door Assembly, left • Screen Door Assembly, right • Arch Frame • Installation Instructions Installation Instructions NOTE: Remove all plastic from packaging. 1. Remove existing top louvre from fireplace by lifting up and pulling out (Refer to top louvre instruction manual for details). 2. Hang arch f