Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Stovax, модель SDV SDVPF-N-B

Производитель: Stovax
Размер: 2.24 mb
Название файла: Lennox_Hearth_SDV_ST_PF_Care_Operation_725040M.pdf

Язык инструкции:enfr

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


Inlet Gas Supply Pressure (all models - millivolt) Fuel # Minimum Maximum Natural Gas 5.0" WC (1.24 kPa) 10.5" WC (2.61 kPa) Propane 11.0" WC (2.74 kPa) 13.0" WC (3.23 kPa) Table 2 Manifold Gas Supply Pressure (all models - millivolt) Fuel # Low High Natural Gas (Lo) 2.2" WC (.55 kPa) (Hi) 3.5" WC (.87 kPa) Propane (Lo) 6.3" WC (1.57 kPa) (Hi) 10.0" WC (2.49 kPa) Table 3 Test gauge connections are provided on the frontofthe millivoltgas controlvalve, identified IN for the inlet and OUT for the manifold side (see Figure 3 on Page 9). These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa). Orifice Sizes -Sea Level to High Altitude (All Models) These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 4). For elevations above 4500 feet, contact your gas supplier or qualified service technician. Deration -At higher elevations, the amount of BTU fuel value delivered must be reduced by either: • Using gas that has been derated by the gas company. • Changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1 -latest edition or, in Canada, the CAN/CSA-B149.1 codes - latest edition. Installtheapplianceaccordingtotheregulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN/CSA-B149.1 - latest edition. NOTE: Flame appearance will diminish 4% per thousand feet. NOTE: Each model has two burners and 2 Orifices. Burner Orifice Sizes Elevation 0-4500 feet ( 0-1372 meters) Elevation Feet (meters) Natural Gas drill size (inches) Propane Gas drill size (inches) 0-4500 (0-1372) #44 (.086") * 60J80 • #55 (.052")** 19L52 • Table 4 * Standard size installed at factory ** Standard size in LP conversion kit • Part /Cat. Number Burn-in Period During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the burn-in period may take a few hours or a few days. KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. If an optional blower is installed, Do Not turn it on during the Burn-In period. A white film may develop on the glass front during the first few fires as part of the curing process. The glass should be kept clean during thefirsttwoweeksofusetopreventthefilmfrom baking on (making it very difficult to remove). See Cleaning Glass on Page 10. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING WARNING AVERTISSEMENT Les jeunes enfants devraient etre surveilles etroitement lorsqu’ils se trouventdanslamemepiecequel’appareil.Lestoutpetits,lesjeunesenfants ou les adultes p...

Эта инструкция также подходит к моделям:
Камины - SDV SDVPF-N-B (2.24 mb)
Камины - SDV SDVPF-N-B (2.24 mb)
Камины - SDV SDVST-N-B (2.24 mb)
Камины - SDV SDVST-N-B (2.24 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории