Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Superior, модель CDST-CMP

Производитель: Superior
Размер: 4.28 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. THE QUALIFIED SERVICE AGENCY PERFORMING THIS INSTALLATION ASSUMES RESPONSIBILITY FOR THIS CONVERSION. AVERTISSEMENT: CET EQUIPEMENT DE CONVERSION SERA INSTALLE PAR UNE AGENCE QUALIFIEE DE SERVICE CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISES AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDE DE CARBONE PEUT RESULTER LE DOMMAGES CAUSER DE PROPRIETE, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIEE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET EQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLETE JUSQU'A L'OPERATION DE L'APPAREIL CONVERTI EST CHEQUE SUIVANT LES CRITERES ETABLIS DANS LES INSTRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L'EQUIPEMENT. Millivolt Appliances Step 4. Refer to Figure 64 and the instructions provided with the kit. Using a Torx T20, remove and discard the three pressure regulator mounting screws. Remove the pressure regulator, spring, poppet, diaphragm and bushing. Discard all removed components. Ensure the rubber gasket installed on the back of the replacement pressure regulator is properly positioned and install the new pressure regulator using the new screws supplied with the kit. Tighten screws to 25 In. lb. torque. Step 1. Turn off the gas supply to the appliance. a. Open the control compartment access panel, by actuating the spring-loaded magnetic catches securing the panel, gently depressing the outer top corners of the panel until the catches "pop" the panel free and allowing it to swing out and down to open. b. Locate the two (2) latches at the top of the control compartment. To disengage the two latches from the bottom vee-flange of the glass enclosure panel, reach for the handles located towards the back of the latches and pull the handles down toward the front of the unit. c. Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance. Step 2. Carefully remove the log set. Exercise care as not to break the log set. Step 3. Referring to Figure 63, remove the front burner and then the rear burner. Step 5. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 KPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. Step 6. Refer to Figure 65 on page 28 and remove the pilot hood assembly to access the hexed pilot orifice. Remove and replace the orifice with the one provided with the kit. Pilot Orifice Figure 65 Pilot Orifice Figure 65 Step 7. Honeywell Electronic Valves - See Figure 66 and the instructions provided with the kit. Remove the slotted cap screw, o-ring, pressure-regulating adjusting screw and spring. Retain all parts for possible later use. Install new components from the kit. Black cap and red spring for propane gas units. Silver cap and stainless steel spring for natural gas units. Before installing the cap, attach manometer to the manifold side pressure test fitting and adjust screw until pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. Spring AdjustingScrew Slotted Cap PSI OFF I ONCONTROL IGNITE Manifold Pressure Test Port Inlet Pressure Test Port Figure 66 See Figure 67and replace the pilot orifice as follows: Remove the ignitor assembly retainer clip, and carefully remove the ignitor assembly. Exercise extreme care to prevent damage to or breakage of the ignitor assembly. Remove the screw securing the pilot assembly to its mounting bracket. Back off the flare nut at the end of the pilot gas line to free the pilot assembly from the gas line. Remove the pilot orifice and replace it with the one provided with the conversion kit. Reinstall the pilot assembly by reversing the steps detailed here. When reinstalling the ignitor assembly, use extreme care to prevent damage and breakage. Do not apply any leverage to the ignitor assembly while restoring the retainer clip to its original position. Retaining Clip IgnitorAssembly Pilot AssemblyPilot Orifice Flare Nut Note: If the ignitor is damaged, a replacement kit is available, order Catalog No. 87L54. Figure 67 All Models Step 8. (Refer to Figure 63 on page 27) A. Remove the two orifices from the manifold and replace them with the ones provided in the kit. The following table shows the orifice sizes for natural and propane models. Figure 68 illustrates the orifice. B. Install rear burner first, followed by front burner, as shown inFigure 69. Ensure that the arm of the venturi of each burner is ho...

Эта инструкция также подходит к моделям:
Камины - CDCR-CEN (4.28 mb)
Камины - CDCL-CEP (4.28 mb)
Камины - CDCL-CEN (4.28 mb)
Камины - CDCL-CMN (4.28 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории