Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации GN National Electric, модель GN

Производитель: GN National Electric
Размер: 2.59 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. HEATER INSTALLATION FOR DIRECT VENT Locating Wall Opening The recommended location for this furnace is on an outside wall. Locate wall studs so that wall vent opening will be located between wall studs. The wall opening required for venting is a 3 1/2” (89mm) minimum diameter opening. Refer to Figures 3 and 6 for positioning the heater on wall and for locating gas line connection and vent opening. Furnace can sit on the floor. 19/16” 43/32” Figure 2 22618-4-1106 Page 9 CLEARANCES FOR SINGLE FLUE 1. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 115 VAC wall receptacle to properly power appliance. 2. When facing the front of the furnace, the minimum clearances from casing to combustible construction are 0” (0mm) on top, 0” (0mm) on each side, recommend 4” (102mm) on right side for serving and 0” (0mm) from the floor and 2” (51mm) to rear wall. 3. The minimum distance from the center of the vent cap to the nearest outside corner or obstruction is 12” (305mm). The bottom of the exhaust vent terminal and the air intake shall be located at least 12” (305mm) above grade and must be vented outside. WARNING: The nearest point of the vent cap should be a minimum horizontal distance of six (6) feet (1.83m) from any pressure regulator. In case of regulator malfunction, the six (6) feet (1.83m) distance will reduce the chance of gas entering the vent cap. Installation on Rugs and Tile If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. HEATER INSTALLATION FOR SINGLE FLUE Locating Wall Opening The recommended location for this heater is on an outside wall (the unitcanbelocatedonaninsidewallbutmustnotexceed20’(6.096m) in exhaust vent length). Locate wall studs so that wall vent opening will be located between wall studs. The wall opening required for venting is a 1 7/8” (48mm) minimum diameter opening. Refer to Figures 3 to 6 for positioning the heater on wall and for locating gas line connection and vent opening. Heater can sit on the floor. Page 10 22618-4-1106 22618-4-1106 Page 11 SPECIFICATIONS Heater with Pedestal and Single Flue Adaptor 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” BSP Connection (Inside) 5 Single Flue Adaptor 28 3/16” (71.6cm) 33 3/4” (85.7cm) 8 5/8” (21.9cm) 17 5/8” (44.8cm) 5 - SINGLE FLUE ADAPTOR 12 1/4” (31.1cm) 1 - FLUE OUTLET 13/16” (2.1cm) 2 - AIR INLET 7 9/16” (19.2cm) 2 13/16” 1 7/16” (7.1cm) (3.7cm) 1” (2.5cm) 3 - ELECTRIC CORD 4 - 3/8” BSP CONNECTION INSIDE 1 .” (3.8cm) 6 1/8” (15.6cm) 3 9/16” (9.0cm) Figure 3 Page 12 22618-4-1106 SPECIFICATIONS - (continued) Heater without Pedestal 1 Flue Outlet 2 Air Inlet 3 Electric Cord 4 3/8” BSP Connection (Inside) 28 3/16” (71.6cm) 25 1/8” (63.8cm) 27 3/4” (70.5cm) 17 5/8” (44.8cm) 3 9/16” (9.0cm) 16 15/16” (43.0cm) 1 - FLUE OUTLET 2 - AIR INLET 3 - ELECTRIC CORD 4 - 3/8” BSP CONNECTION INSIDE 1” (2.5cm) 7 9/16” (19.2cm) 2 13/16” 1 7/16” (7.1cm) (3.7cm) 6 1/8” (15.6cm) 1 .” (3.8cm) 3 9/16” (9.0cm) 13/16” (2.1cm) 1 - FLUE OUTLET Figure 4 SPECIFICATIONS - (continued) Fireplace Insert with Mantel surround with slim top panel 1 Flue Outlet 2 Electric Cord 3 3/8” BSP Connection (Inside) 4 Surround 293/4” (75.6cm) 357/16” (90.0cm) 515/16”(15.1cm) 2313/16” (60.5cm) 5” (12.7cm)115/16” (28.7cm) 1-FLUEOUTLET39/16” (9.0cm) 4-SURROUNDASSEMBLY1-FLUEOUTLETAIRINLET13/16”(2.1cm) 1”(2.5cm) 2-ELECTRICCORD79/16” (19.2cm) 213/16” (7.1cm)17/16” (3.7cm) 3-3/8”BSPCONNECTION61/8” (15.6cm) 1.” (3.8cm) 39/16” (9.0cm) (INSIDE) Figure 5 22618-4-1106 Page 13 SPECIFICATIONS - (continued) Fireplace Insert with Mantel Surround with short top panel 1 Flue Outlet 2 Electric Cord 3 3/8” BSP Connection (Inside) 4 Surround 5 Air Inlet 357/16” (90.0cm) 293/4” (75.6cm) 515/16”(15.1cm) 2313/16” (60.5cm) 101/8” (25.7cm) 63/16” (15.7cm) 1-FLUEOUTLET39/16”(9.0cm) 1615/16” (43.0cm) 4-SURROUNDASSEMBLY1-FLUEOUTLET13/16”(2.1cm) 5-AIRINLET79/16” (19.2cm) 213/16” (7.1cm)17/16” (3.7cm) 1.” (3.8cm) 39/16” (9.0cm) 1” (2.5cm) 2-ELECTRICCORD 3 -.”BSP 6 1/8” CONNECTION (15.6cm) INSIDE Figure 6 Page 14 22618-4-1106 CLEARANCE TO COMBUSTIBLES Freestanding Models CCABBFigure 7 Figure 8 Freestanding Units A Rear Wall to Heater 2” Single Flue and 1 1/4” Direct Vent B Side Wall to Heater 0”/4” recommended for serviceability C Corner Installati...

Эта инструкция также подходит к моделям:
Камины - BP)-1 (2.59 mb)
Камины - CP (2.59 mb)
Камины - GP)-1 (2.59 mb)
Камины - PV-28SV50 (2.59 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории