Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Lennox Hearth, модель 2-EN53-VDLPM

Производитель: Lennox Hearth
Размер: 2.26 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of (V) vertical, you are allowed 5 feet of (H) horizontal run, up to a maximum horizontal run of 20 feet. V Minimum feet feet 5 (1.524) 1 (0.305) 10 (3.048) 2 (0.610) 15 (4.572) 3 (0.914) 20 (6.096) 4 (1.219) (meters) TABLE E (meters) 1 1 H + H1 = 20 feet (6.096 m) Max. V + V + H + H = 40 ft. (12.192 m) Max. H + H1 Maximum + V1 V* H H1 V1 **Ceiling Firestop/Spacer (SV4.5VF) **When using Secure Flex, use Firestop/Spacer SF4.5VF **Ceiling Firestop/Spacer (SV4.5VF) Support Bracket *To Top Surface Of Fireplace ***Wall Firestop/Spacer ***Wall Firestop/Spacer ***Use Firestop/Spacer SV4.5HF or SF4.5HF when using Secure Vent or Secure Flex respectively. Use Firestop/Spacer SV4.5HF5 or SF4.5HF5 when using Secure Vent or Secure Flex on horizontal vent runs for the MPLDV35/40/45 with a center line lower than 48” (1219 mm) above the fireplace top wrapper surface. In all cases the firestop/spacer provided with the termination may be used with the termination, frame to 5” clearance where applicable. HORIZONTAL VENT FIGURES/TABLES (CONTINUED) Figure 33 - Top Vent - THREE 90 DEGREE ELBOWS - ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE Figure 32 - Top Vent - TWO 90 DEGREE ELBOWS - ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE See Table 3 on page 18 as an aid in venting component selection for a particular range of exterior wall thicknesses. See Table 3 on page 18 as an aid in venting component selection for a particular range of exterior wall thicknesses. H + H1 Maximum V Minimum feet feet 5 (1.524) 1 (0.305) 10 (3.048) 2 (0.610) 15 (4.572) 3 (0.914) 20 (6.096) 4 (1.219) V + H + H1 = 40 feet (12.2 m) Max. H + H1 = 20 ft. (6.096 m) Max. TABLE D (meters) (meters) Square termination (SV4.5HT-2) shown. Square termination (SV4.5HT-2) shown. V* H H1 ***Ceiling Firestop/Spacer (SV4.5VF) ***Note - When using Secure Flex, use Firestop/Spacer SF4.5VF Support Bracket *To Top Surface Of Fireplace **Wall Firestop/Spacer **Wall Firestop/Spacer **Use Firestop/Spacer SV4.5HF or SF4.5HF when using Secure Vent or Secure Flex respectively. Use Firestop/Spacer SV4.5HF5 or SF4.5HF5 when using Secure Vent or Secure Flex on horizontal vent runs for the MPLDV35/40/45 with a center line lower than 48” (1219 mm) above the fireplace top wrapper surface. In all cases the firestop/spacer provided with the termination may be used with the termination, frame to 5” clearance where applicable. VERTICAL OR HORIZONTAL VENTING USING SECURE FLEX KITS AND COMPONENTS VERTICAL OR HORIZONTAL VENTING USING SECURE FLEXKITS AND COMPONENTS Secure Flex kits come with an included adapter that can be fitted to the appliance collar or the inclined channel end of the last Secure Vent (SV4.5) vent section in a rigid system in the exact same fashion as any other Secure Vent section. Align the dimpled end of the adapter over the previously installed section or appliance collar, adjusting the radial alignment until the four locking dimples of the adapter are aligned with the inlets of the four incline channels of the last vent section or collar. Push on the adapter until it fully engages, then twist the adapter clockwise running the dimples down and along the incline channels until they seat at the end of the channels. Attach the flexible vent to the adapter as follows (also see Figure 34 ): A. Install the Inner Flex Pipe 1. Install the small gear clamp loosely around the inner flexible vent pipe, push it back out of the way. 2. Apply a bead of Mill-Pac Black (700°F) high temperature sealant - Catalog No. 10K81) to the inner adapter collar, approximately 1/2 inch from the end. 3. Pull and extend the inner flexible vent pipe. 4. Slide the inner flex pipe over the adapter collar. Ensure the flexible vent pipe completely engages the adapter collar to a distance of 1... inches from the end, and that it is free from damage or tears. 5. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adapter inner collar approximately 3/4 inch from the end of the flex. 6. Install three screws 120 degrees apart through the flexible vent pipe and into the adapter collar just below the gear clamp to provide additional security to the connection. B. Install the Outer Flex Pipe 1. Install the large gear clamp loosely around the outer flexible vent pipe, push it back out of the way. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 21 GEAR CLAMPS Adapter(SV4.5RF) Apply ONLY MIL-PAC BLACK HIGHTEMPERATURE SEALANT (Catalog No. 10K81) to the outside surface of both collars of the adapter (be especially careful to fill the grooves of the outer collar to be covered by the flexible pipe) and slide flexible pipe overinner and outer adapter collars. NOTE: OUTER PIPE IS PULLED AWAY TO SHOW THE DETAIL OF THE INNER PIPE FLEX VENT 1-3/4 in. (44 mm) Flexible Pipe and Adapter Outer Collar Overlap 1-3/4 in. (44 mm) Flexible Pipe and Adapter Inner Collar Overlap SECURING SCREW (3 PLACES EQUIDISTANT JUST BELOW GEAR CLAMP) Attach Adapter to Ap...

Эта инструкция также подходит к моделям:
Камины - 2-MN53-VDLPM (2.26 mb)
Камины - 2-MP53-VDLPM (2.26 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории