Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated in 12 (305) MANTEL 10 (254) MANTEL 8 (203) MANTEL 6 (152) MANTEL 4 (102) MANTEL 18 (457) 14 (356) 12 (305) 2 (51) MANTEL TOP OF APPLIANCE 8 (203) 10 (254) MANTEL CLEARANCES Inches (mm) 16 (406) Figure 45 Figure 46. Combustible Materials Allowed In Shaded Area “Safe Zone” 12" 45° 17" Side Wall Side Wall 14" Figure 46 COLD CLIMATE INSULATION Top View Of Fireplace 5" Min. Distance 8-1/4" To Protected Side Wall Min. Distance To Unprotected Side Wall For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation. In cold climates, if the fireplace is being installed on a cement slab, a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room. It also helps to sheetrock inside surfaces and tape for maximum air tightness and caulk firestops. INSTALLATION ACCESSORIES Listed Secure Vent™Components Cat.No. Model No. Description **94L10 SV4.5HTSS Horizontal Small Square Termination with Firestop/Spacer (96K80) and Adapter (74L61) **98L27 SV4.5HTSSL Horizontal Small Square- Long Termination with Firestop/Spacer (96K80) and Adapter (74L61) Sealant Listed Cat. No. 10K81 89L40 91L66 91L67 H2248 H2249 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Secure Flex™Components Model No. SFMP SFMP-12 SF-GC4-6 SF-GC7-6 SF4.5HF SF4.5VF Description Mil Pac Black Hi-Temperature Sealant Mil Pac Black Hi-Temperature Sealant -Bulk Pack 12 Gear Clamp 4.5in. (114 mm) for Flex (6 pieces) Gear Clamp 7.5 in. (190.5 mm) for Flex (6 pieces) Firestop/Spacer -10 Pack Horizontal (3-1-1 spacing) Firestop/Spacer -10 Pack Vertical (1-1-1 spacing) **May be used with 30" and 35" models only. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 27 INSTALLATION ACCESSORIES CONTINUED Listed Secure Flex™Components Cat. No. Model No. Description These termination kits include firestop/spacer, gear clamps and flex adapter. H1969 SF4.5HT-2 Horizontal Square Termination without Flex 77L87 SFKIT12 Flex Square Term. with 12 in. (305 mm of *compressed Flex 77L88 SFKIT18 Flex Square Term. with 18 in. (457 mm) of *compressed Flex 77L89 SFKIT24 Flex Square Term. with 24 in. (610 mm) of *compressed Flex 77L90 SFKIT36 Flex Square Term. with 36 in. (914 mm) of *compressed Flex 77L91 SFKIT48 Flex Square Term. with 48 in. (1219 mm) of *compressed Flex 56L74 SFVT30 Vertical Termin. for Flex (flat to 6/12) with Flex Adapter, section of rigid vent, roof support collar assembly, roof flashing and storm collar. 56L75 SFVT45 Vertical Termin. for Flex (6/12 to 12/12) with Flex Adapter section of rigid vent, roof support collar assembly, roof flashing and storm collar. 60L10 SF-18 18 ft. (5.49 m) *compressed Flex 98K03 SF-12 12 ft.(3.66 m) *compressed Flex *All compressed flex vents can be expanded up to two times. **May be used with 30" and 35" models only. Cat. No. Model No. Description These termination kits include firestop/spacer, gear clamps and flex adapter. **94L09 SF-HTSS Horizontal Small Square Termination without Flex **94L04 SFKIT12SS Flex Small Square Term. with 12 in. (305 mm of *compressed Flex **94L05 SFKIT18SS Flex Small Square Term. with 18 in. (457 mm) of *compressed Flex **94L06 SFKIT24SS Flex Small Square Term. with 24 in. (610 mm) of *compressed Flex **94L07 SFKIT36SS Flex Small Square Term. with 36 in. (914 mm) of *compressed Flex **94L08 SFKIT48SS Flex Small Square Term. with 48 in. (1219 mm ) of *compressed Flex Cat. No. Model No. Description H1988 H1985 H1987 H1986 H5820 CTSA-33 CTSO-33 CTSO-44 CTSO-46 4.5HTSK Chase Top Shroud Kit, Arch Top 3 x 3 Chase Top Shroud Kit, Open Top 3 x 3 Chase Top Shroud Kit, Open Top 4 x 4 Chase Top Shroud Kit, Open Top 4 x 6 Termnation Shroud Kit Listed Secure Vent™Components Cat.No. Model No. Description H1968 SV4.5HT-2 Horizontal Square Termination with Firestop/Spacer (96K80) and Adapter (74L61) H2152 SV4.5CGV-1 Vertical Termination H4687 H4716 H4717 SV4.5CTS SV4.5CTS-B SV4.5CTS-TC Chase Top Term. Square Chase Top Term. Square, Blk Terra Cotta Termination 77L70 SV4.5L6 6 inch (152 mm) Vent Section 77L71 SV4.5L12 12 inch (305 mm) Vent Section 77L72 SV4.5L24 24 inch (610 mm) Vent Section 77L73 SV4.5L36 36 inch (914 mm) Vent Section 77L74 SV4.5L48 48 inch (1219 mm) Vent Section 77L75 SV4.5LA Telescopic Section 77L76 SV4.5E45 45 Degree Elbow 77L77 SV4.5E90 90 Degree Elbow The following flashings come packaged with a storm collar. 77L78 SV4.5F Flat Roof Flashing 77L79 SV4.5FA 1/12 to 7/12 Adjust. Flashing 77L80 SV4.5FB 7/12 to 12/12 Adjust. Flashing 77L81 SV4.5SC6 Storm Collars (6 collars/box) H6183 SV4.5HF5 Firestop/Spacer Hor...
Эта инструкция также подходит к моделям:Камины - 2-MN53-VDLPM (2.26 mb)
Камины - 2-EN53-VDLPM (2.26 mb)