Войти:
Скачали: 1   Размер: 472 kb   Производитель: Dyna-Glo  
Категория: Электрообогреватели
@name

2. Drain Fuel Tank through Fuel Cap Opening and wash Fuel Cap Filter with clean fuel. 3.Using a small amount of kerosene,swirl and rinse the inside of the tank. Never mix water with the kerosene as it will cause poor operation of the heater. Pour the kerosene out making sure that you remove it all. IMPORTANT : Do not store kerosene over summer months for use during next next heating season. Using old fuel could damage heater. 4. Reinstall Fuel Cap Filter and Fuel Cap(See Figure 11). IMPORTANT :

Скачали: 3   Размер: 1 mb   Производитель: Dyna-Glo  
Категория: Электрообогреватели
@name

EXPLODED PARTS DRAWING (RMC-KFA45T/65T/120T/170T Models Only) NOTE: SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 32 33 16 15 25 23 24 30 22 18 28 31 3 20 15 19 21 14 26 23-1 11 12 13 2 4 1 6 27 5 29 8 9 10 7 17-7 17-8 17-5 17-6 17-3 17-9 17-10 17-4 17-2 17-1 22-11 22-15 22-13 22-17 22-18 22-9 22-19 22-16 22-8 22-10 22-14 22-12 22-6 22-7 22-4 22-3 22-5 22-1 22-2 Burner Head Assembly Motor Pump Assembly 20 21 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 13. EXPLODED PARTS DRAWING

Скачали: 0   Размер: 1 mb   Производитель: Dyna-Glo  
Категория: Электрообогреватели
@name

INTRODUCTION 2 2. FEATURES 2 3. UNPACKING AND ASSEMBLY 4 4. KEROSENE (1-K OR NO. 1 FUEL OIL) 6 5. OVERVIEW OF HEATER DESIGN 7 6. FUELING YOUR HEATER 8 7. OPERATION 8 8. LONG TERM STORAGE OF YOUR HEATER 9 9. MAINTENANCE 9 10. TROUBLE SHOOTING GUIDE 16 11. WIRING DIAGRAM 17 12. SPECIFICATIONS 19 13 EXPLODED PARTS DRAWING 20 14. PARTS LIST 22 1. INTRODUCTION Please read this USER’S MANUAL carefully. It will show you how to assemble, maintain, and operate the heater safely and efficiently to obtain

Скачали: 8   Размер: 1 mb   Производитель: Dyna-Glo  
Категория: Электрообогреватели
@name

- Remove ignitor wire from spark plug. - Remove spark plug from bracket-spark using medium phillips screwdriver. - Clean and regap spark plug electrodes to 3.5mm gap.(0.138") - ReInstall spark plug in bracket-spark. - Attach ignitor wire to spark plug. - Reinstall fan and upper shell. G.) PHOTOCELL CLEAN PHOTOCELL ANNUALLY OR AS NEEDED. (For RMC-KFA 45T/65T/120T/170T Models Only) - Remove upper shell (See page 9). - Remove fan (See page 10). - Remove photocell from it’s mounting. Clean photocell

Скачали: 1   Размер: 472 kb   Производитель: Dyna-Glo  
Категория: Электрообогреватели
@name

This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most importantly, how to operate the heater in a safe and efficient manner. Please keep this manual for future reference. CFM HOME PRODUCTS 2695 MEADOWVALE BOULEVARD MISSISSAUGA, ONTARIO L5N 8A3 1-800-668-5323 EDITION 2004 06/04 Rev. 00 2 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! ITEM PAGE # PRECAUTIONS - SAFETY GUIDE 1 1. INTRODUCTION 2 2. FEATURES 2 3. UNPACKING AND AS

Скачали: 7   Размер: 1 mb   Производитель: Dyna-Glo  
Категория: Электрообогреватели
@name

Red containers are associated with gasoline. NEVER store kerosene in the living space. Kerosene should be stored in a well ventilated place outside the living area. NEVER use any fuel other than 1-K kerosene (#1 fuel oil is an acceptable substitute.) NEVER use fuel such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners, or other oil compounds in this heater. These are volatile fuels that can cause an explosion or uncontrolled flames. NEVER store kerosene in direct sunligh





Категории