|
Фрагмент инструкции
4. Raise the heater to its upright position and push the heater onto the bracket to engage the top latch. Fig. 2 Access to the controls The controls cover on your heater has a latch which may be locked shut if desired using a small bladed screwdriver -see Fig. 3. To open the cover insert the blade of the screwdriver in the small slot and rotate a quarter of a turn clockwise to disengage the latch. The cover may then be hinged back towards the wall for access to the controls. Fig. 3 Operation - W models -Thermostat only Control of Output and Temperature (see Fig. 4) The isolating switch in the fixed wiring should be used to switch the product ON and OFF. When ON the product will be controlled by the thermostat. Fig. 4 Thermostat Operation The heater is fitted with an adjustable thermostat enabling the room temperature to be controlled by adjusting the setting accordingly. The setting represents a room temperature * of approximately 5°C and may be used for protection against frost. Higher temperature settings range from 1 to 6 (max.) creating a maximum room temperature of approximately 30°C. Switch on the heater and turn the thermostat knob to the position corresponding to the required temperature for the room. The heater will then maintain the room temperature at the chosen level, provided that the correct size of heater has been selected for the room to be heated. NOTE - Should your heater fail to come on when the thermostat knob is at a low setting, this may be due to the room temperature being higher than the thermostat setting. Operation - TW Models - Thermostat and Timer Control of Output and Temperature (see Fig. 5) The slide switch on the timer unit controls the electricity supply to the heating elements on TW models. Fig.5 Thermostat Operation - see above. Using the Timer The heater must be connected to the electricity supply for the timer to operate. Set the timer by rotating the dial clockwise until the correct time of day is indicated opposite the datum mark (located at centre front of the timer - see Fig. 5). 'OFF’ Position Set the timer switch to • position. The timer operates but the heater will not output any heat, as the electricity supply to the heating elements has been disconnected. Manual Operation Set the timer switch to .. position. The heater will now operate continuously under the control of the thermostat - see 'Thermostat Operation' above. Automatic Operation Set the timer switch to .. position. The panel will now operate during set 'ON' periods under the control of the thermostat. To set the timer's 'ON' and 'OFF' periods: 1. Using your finger tip or the tip of Fig. 6 a pencil, push in as many segments as necessary around the dial, according to the times you don't require heat - see Fig. 6. Each segment pushed in switches the heater OFF for that part of the hour. All other segments will be 'ON'. 2. You can select as many 'ON' periods as you like, within the 24-hour day. The settings will repeat every day until changed. 3...
Эта инструкция также подходит к моделям:Электрообогреватели - TPR2-1000W (1.56 mb)
Электрообогреватели - TPR2-1250W (1.56 mb)
Электрообогреватели - TPR2-2000W (1.56 mb)
Электрообогреватели - TPR2-750W (1.56 mb)