Инструкция по эксплуатации Desa, модель RGH3000, RGH3000PR, RGH5500, RGH5500IE, RGH7500IE, RGH11000IE

Производитель: Desa
Размер: 1.15 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Note:When this happens, the engine switch remains in the ON position. The oil alert system is wired into the ON/OFF Switch. If this system shuts down the engine, the engine will not start until you add oil. Add oil to engine (see Engine Oil, page 7). Note:Operate generator on a level surface. If not level, the oil may flow away from the oil level sensing device. This will cause the oil alert system to shut down engine. See engine owner’s manual for more information. ENGINE SWON OFF Models RGH3000, and RGH5500 Models RGH5500IE, RGH7500IE, and RGH11000IE HONDA OFF ON START ENGINE SW CIRCUIT BREAKER Figure 2 - Engine Switch Location FULL POWER SELECTOR SWITCH All models except RGH3000, RGH3000PR, RGH7500IE, and RGH11000IE have a full power selector switch on the control panel. The switch has two positions: 120 VOLT ONLY, and 120/240 VOLT. 120 VOLT ONLY: This position sends full power to the 120V receptacles only. 240V power is not available. Use this position when powering 120V items only. 120/240 VOLT: This position sends full power to the 120/240V receptacle. It also powers the 120V receptacles at reduced wattage capacity. Selector Full Power 120 V ONLY 120/ 240V 120 VOLT ONLY Position Selector Full Power 120 V ONLY 120/ 240V 120/240 VOLT Position Figure 3 - Full Power Selector Switch IMPORTANT:Do not move the full power selector switch while powering electrical items. Unplug all items before moving switch. Failure to do so can damage switch. Models RGH3000, RGH3000PR, RGH7500IE, and RGH11000IE do not have this switch. These models provide full power to all receptacles. ELECTRIC START (Models RGH5500IE, RGH7500IE, and RGH11000IE) Models RGH5500IE, RGH7500IE, and RGH11000IE have electric starters. A battery is not supplied with generator. You must provide a 12-volt, 32-amp-hour battery. For more battery information, see Battery, page 8. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE All models have a 120-volt ground fault circuit interrupter (GFCI) receptacle. The GFCI receptacle is on the control panel or top cover of alternator (models RGH3000 and RGH3000PR only). The GFCI protects you against hazardous electrical shock caused when your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is ‘live’ through faulty mechanism, damp or worn insulation, etc. When protected by the GFCI, you may still feel a shock, but the GFCI should cut it off quickly. A person in normal health should not receive serious injury.Note:Infants and very small children may still be affected. Test Procedure Check the GFCI receptacle every month. This insures it is working right. 1. Push black TEST button. Red RESET button should pop out. This should trip GFCI, resulting in no electrical power at receptacle. Verify this by plugging test lamp with good bulb into receptacle. If lamp does not work, GFCI receptacle is good. WARNING: If RESET button does not pop out, do not use the GFCI receptacle. Contact a qualified electrician for repairs. 2. If the GFCI receptacle tests okay, restore power by pushing the RESET button back in. The test lamp should work at this time. IMPORTANT:You must press the RESET button firmly and fully. It should lock into place. If the GFCI does not lock into place, do not use receptacle. Contact a qualified electrician for repairs. RESETTEST Figure 4 - GFCI Receptacle 6 104960 OWNER’S MANUAL GENERATOR FEATURES Continued ENGINE CIRCUIT BREAKER (Models RGH5500IE, RGH7500IE, and RGH11000IE) This circuit breaker, or fuse, protects the battery charging circuit. A short circuit will trip the circuit breaker. The circuit breaker will also trip if you install battery wrong. Push circuit breaker button to reset. On Model RGH11000IE, the fuse is located inside of the Keyswitch box. Engine Circuit Breaker Button OFF ON START ENGINE SW CIRCUIT BREAKER ON/push OFF Figure 5 - Engine Circuit Breaker RECEPTACLE CIRCUIT BREAKER The circuit breakers protect the receptacles and alternator. Overloading generator will trip circuit breaker. A short circuit in item being powered will also trip breaker. If this occurs, unplug electrical load from receptacle. Let circuit breaker cool down. Push circuit breaker button to reset. Electric motors need higher starting current. They require up to three-times their rated wattage to start. The starting current needed may be too high. This can cause nuisance circuit breaker tripping. To help prevent this, start electric motors first. Connect additional items to generator after starting motors. If this continues to happen, reduce the total generator load. ENGINE OIL We ship the generator without oil in the engine crankcase. You must add oil before starting engine. See engine owner’s manual for specific oil type. CHECKING OIL LEVEL AND ADDING OIL Follow steps below to check oil level. Make sure engine is level and stopped. 1. Remove dipstick (see Figure 7). Wipe dipstick clean. 2. Insert dipstick into oil filler neck. Do not s...

Эта инструкция также подходит к моделям:
Электрогенераторы - RGH3000 (1.15 mb)
Электрогенераторы - RGH3000PR (1.15 mb)
Электрогенераторы - RGH5500 (1.15 mb)
Электрогенераторы - RGH5500IE (1.15 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории