Инструкция по эксплуатации Desa, модель RGH3000PR

Производитель: Desa
Размер: 1.15 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This can cause fire or explosion. After refueling, tightly close fuel tank cap. • Do not spill fuel. Fuel or fuel vapor may ignite. If fuel spills, make sure area is dry before starting engine. • Never smoke in refueling area. Never allow open flames or sparks in area. • Store fuel in approved container. Store fuel in a well- vented area free of open flames or sparks. Use clean, fresh, unleaded gasoline. Use gasoline with octane rating of 86 or higher. Service station gasoline pumps should display the octane rating. Using gasoline with lower octane level could damage engine. Avoid getting dirt, dust, or water in fuel tank. Do not mix oil with gasoline. See engine owner’s manual for more information. 20 20 Normal Tripped Figure 6 - Receptacle Circuit Breaker Button Note:High ambient temperature will cause nuisance tripping. 104960 7 8 104960 PORTABLE GASOLINE GENERATORS ® Figure 10 - Battery Hold-Down System (Model RGH7500IE Shown) 120 ONLY 120 240V ENM 00000005 HOURS 1/10 FULL POWER Battery Mounting Bracket Battery Hook Bolt Nut IMPORTANT: Make sure battery connections are the correct polarity. Electric start generators use negative ground, 12-volt DC starting system. Models RGH5500IE, RGH7500IE, and RGH11000IE have an electric starter. A battery is not supplied with generator. You must provide a 12-volt, 32-amp-hour battery. The positive and negative battery cables are supplied with generator. You must install these cables before mounting battery. Starter Solenoid Figure 8 - Connecting Red, Positive (+) Battery Cable to Engine Starter Solenoid (Model RGH7500IE Shown) Figure 9 - Connecting Black, Negative (-) Battery Cable to Engine Block (Model RGH7500IE Shown) Red, Positive (+) Battery Cable Black, Negative (–) Battery Cable MOUNTING BATTERY TO GENERATOR 1. Secure battery to generator by battery hold-down system. This system consists of the battery mounting bracket, hook bolts, and nut (see Figure 10). Note: Model RGH11000IE battery is located on opposite side as shown (see Figure 11, page 9). 2. Locate the red, positive (+) battery cable from starter solenoid. Connect it to the positive (+) battery terminal (see Figures 12 and 13, page 9). 3. Locate the black, negative (–) battery cable attached to engine block. Connect it to the negative (–) battery terminal (see Figures 12 and 13, page 9). 4. Check battery before starting engine. Make sure fluid levels are full. Make sure battery is charged. See engine owner’s manual for more information. BATTERY (Models RGH5500IE, RGH7500IE, and RGH11000IE) WARNING: Battery gives off explosive gases. Keep sparks, flames, and cigarettes away. Do not remove or install battery cables when engine is cranking or running. Only service or use battery in a well-vented area. WARNING: Battery contains sulfuric acid. Contact with skin or eyes may cause severe burns. Do not tilt generator with battery installed. Tilting could cause battery acid to spill. Wear protective clothing and face shield when servicing. Keep out of children’s reach. • If battery acid gets on your skin, wash with water. • If battery acid gets in your eyes, flush with water at least 15 minutes. Call a doctor at once. Battery acid is poisonous. • If swallowed, drink large amounts of water or milk. Follow with milk of magnesia or vegetable oil. Call a doctor at once. CAUTION: If you remove battery, insulate the red, positive (+) battery cable terminal. Insulate with electrical tape. Exposed terminal may spark when generator runs. Always wear safety glasses when working with battery. Make sure battery terminals are clean. Make sure cable connections are tight. Always shut down engine before removing or attaching battery cables. Always remove the negative (–) cable first. Always attach negative (–) cable last. INSTALLING BATTERY CABLES TO ENGINE 1. Attach the red, positive (+) battery cable to the starter solenoid on engine (see Figure 8). The starter solenoid is located directly above the starter on Model RGH11000IE. This cable is factory installed. CAUTION: Do not over tighten positive terminal on starter solenoid. Positive terminal could rotate and cut into negative terminal, causing a short. 2. Attach the black, negative (–) battery cable to the engine block. Use the bolt, nut, and two washers provided with the battery cables. Use long mounting hole on opposite side of engine from starter solenoid. Attach cable as shown in Figure 9. 104960 9 OWNER’S MANUAL Ampere AWG for Length of Load Cord in Feet 50' 100' 150' 2 18 18 18 3 18 18 18 4 16 16 16 5 16 16 16 6 16 16 14 8 16 14 12 10 16 14 12 12 14 14 12 14 14 12 10 16 12 12 10 20 10 10 8 FUEL F FUEL F TO STARTER SOLENOID TO ENGINE BLOCK 120 ONLY 120 240V ENM 00000005 HOURS 1/10 FULL POWER Figure 12 - Connecting Positive and Negative Cables to Battery (Model RGH7500IE Shown) BATTERY Continued Figure 11 - Battery Hold-Down System (Model RGH11000IE Shown) Battery Mounting Bracket FUEL F Figure 13 - Connecting Positive and Negative Cables to Battery (Model RGH11000...

Эта инструкция также подходит к моделям:
Электрогенераторы - RGH3000 (1.15 mb)
Электрогенераторы - RGH3000, RGH3000PR, RGH5500, RGH5500IE, RGH7500IE, RGH11000IE (1.15 mb)
Электрогенераторы - RGH5500 (1.15 mb)
Электрогенераторы - RGH5500IE (1.15 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории