Инструкция по эксплуатации Vulcan-Hart, модель COUNTER CONVECTION STEAMERS 52396

Производитель: Vulcan-Hart
Размер: 88.29 kb
Название файла: 3c79bcd7-7919-4dd7-821d-47840836930d.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


(502) 778-2791 FORM 30896 (10-94) Installation, Operation, and Care of MODELS VSX3, VSX4, VSX5 ELECTRIC COUNTER CONVECTION STEAMERS KEEP THIS MANUAL GENERAL The VSX 3, 4, and 5 Steamers are single compartment electric pressureless steam cookers with an internal electric steam generator that maintains water temperature at approximately 205°F. VSX3 is rated 7.5 kw as standard; 10 kw is optional. VSX4 is rated 10 kw. VSX5 is rated 15 kw. At high altitude locations a lower temperature is required to achieve atmospheric steaming. Contact your Vulcan-authorized service office to have the thermostat adjusted if the steamer will be operated at high altitudes. INSTALLATION UNPACKING Immediately after unpacking the steamer, check for possible shipping damage. If the steamer is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. Prior to installation, verify that the electrical service agrees with the specifications on the machine data plate which is located on the left side panel. LOCATION Allow space for plumbing and electrical connections. Minimum clearances are 2" on the sides and 6" on the back for proper air circulation. Allow adequate access for operating and servicing the steamer (36" at the front of the steamer and 15" above the steamer). LEVELING FEET (Standard) OR 4" ADJUSTABLE LEGS (Optional) Thread the four 2" leveling feet shipped in a bag inside the steamer cabinet into the threaded holes on the bottom corners of the steamer. Or, thread the four optional 4" adjustable legs into the threaded holes on the bottom corners of the steamer. LEVELING Using a spirit level or pan of water in the bottom of the steamer, adjust the leveling feet or the feet on the adjustable legs to level the steamer front-to-back and side-to-side. After the drain is connected, check for level by pouring water onto the floor of the compartment. All water should drain through the opening at the back of the compartment cavity. ANCHORING STEAMER (Without Legs) 1. Place steamer in the desired location on the leveled counter top and mark four corners. Remove the steamer and drill 1/2" holes as indicated in Fig. 1. 2. Apply a bead of RTV or other equivalent sealant around the bottom perimeter edge of the steamer. If anchoring the steamer, this bottom seal is necessary to meet NSF requirements. 3. Set steamer on counter and bolt down securely with 3/8 - 16 bolts (not supplied). STACKING KIT Follow instructions in the stacking kit when installing stacked convection steamers. 24" 20" 2" 27 1/2" 23 1/2" Drill 1/2" holes through counter top Mark 4 corners on counter top PL-50819 Fig. 1 ELECTRICAL CONNECTION WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT. The wiring diagram is located on the right side ...

Эта инструкция также подходит к моделям:
Электрические печи - COUNTER CONVECTION STEAMERS 52397 (88.29 kb)
Электрические печи - COUNTER CONVECTION STEAMERS 52398 (88.29 kb)
Электрические печи - COUNTER CONVECTION STEAMERS 52399 (88.29 kb)
Электрические печи - COUNTER CONVECTION STEAMERS VSX3 (88.29 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории