|
Фрагмент инструкции
The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa) above the inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c. (1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa for LP Gas). 9 INSTALLING THE LEGS INSTALLING THE WORKTOP Bertazzoni ranges must be used only with the legs properly installed. Four height.adjustable legs are shipped with the range in the polystyrene container situated over the appliance. Before installing the legs, position the appliance near its final location as the legs are not suitable for moving the appliance over long distances. After unpacking the range, raise it enough to insert the legs in the appropriate receptacles situated on the lower part of the appliance. Lower the range gently to keep any undue strain from legs and mounting hardware. If possible use a pallet or lift jack instead of tilting the unit. Adjust leg height to the desired level by twisting the inside portion of the leg assembly until the proper height is reached. Check with a level that the cooktop is perfectly level. FRONTGUARD To increase the clearance between the front edge of the worktop and the burners it is possible to install the worktop front guard shipped with the appliance. To install the front guard, hold it with the pointed edges looking up. Align the edges of the front guard with the appropriate receptacles in the bottom of the worktop and press firmly until the front guard is securely attached to the worktop. ATTENTION: once installed the front guard may only be removed by disassembling the worktop. Attempting to remove the front guard without disassembling the worktop will result in permanent damage to the worktop. 10 2 lateral screws from the bottom. INSTALLING THE BACKGUARD The back guard must be installed prior to operation of the appliance for appropriate ventilation of the oven compartment. The supplied back guard is a 2.part assembly. The box also contains a set of metal screws for securing the back guard to the worktop. Disassemble the back guard and position the front part on the worktop. Align the screw holes with the corresponding holes at the back of the worktop. If the holes are not aligned, partially loosen the brackets at the back of the worktop as shown below. Install the front part of the back guard by tightening the 2 central screws from the top and 11 INSTALLING THE ANTI.TIP Stability DEVICE The anti.tip bracket shipped with the range must be properly secured to the rear wall as shown in the picture below. The height of the bracket from the floor must be determined after the range legs have been adjusted to the desired height and after the range has been levelled. Measure the distance from the floor to the bottom of the anti.tip bracket receptacle on the back of the appliance. Position the two anti.tip brackets on the wall at the desired height plus 1/8" (0.32 cm). The brackets must be placed at 2”5/16 (6,0 cm) from the side of the range. The distance between the two bracket is 25”1/4 (64,1 cm). Secure the brackets to the wall with appropriate hardware. Slide the range against the wall until the brackets are fully inserted into their receptacles on the back of the range. INSTALLATION REQUIREMENTS ELECTRICAL A properly grounded and horizontally.mounted electrical receptacle Type NEMA 14.50R should be installed no higher than 3" (7.6 cm) above the floor, no less than 2” (5 cm) and no more than 8” (20,3 cm) from the right side (facing product); refer to ELECTRICAL CONNECTION section pag. 13. Check all local code requirements. GAS An agency.approved, properly.sized manual shutoff valve should be installed no higher than 3" (7.6 cm) above the floor and no less than 2” (5 cm) and no more than 8” (20.3 cm) from the left side (facing product). To connect gas between shut.off valve and regulator, use agency.approved, properly sized flexible or rigid pipe. Check all local code requirements. 12 INSTALLATION ADJACENT TO KITCHEN CABINETS This range may be installed directly adjacent to existing countertop high cabinets (36" or 91.5 cm from the floor). For the best look, the worktop should be level with the cabinet countertop. This can be accomplished by raising the unit using the adjustment spindles on the legs. ATTENTION: the range CANNOT be installed directly adjacent to kitchen walls, tall cabinets, tall appliances, or other vertical surfaces above 36" (91.4 cm) high. The minimum side clearance in such cases is 6" (15.2 cm). Wall cabinets with minimum side clearance must be installed 18" (45.7 cm) above the countertop with countertop height between 35 .” (90.2 cm) and 37 .” (94.6 cm). The maximum depth of wall cabinets above the range shall be 13" (33.0 cm) EXHAUST HOOD INSTALLATION This range will best perform when used with PRO line Bertazzoni exhaust hoods. These hoods have been designed to work in conjunction with the Bertazzoni range and have the same finish for a perfect look. For maximum performance, the ...
Эта инструкция также подходит к моделям:Электрические печи - X304PIRCR (2.72 mb)
Электрические печи - X304PIRGI (2.72 mb)
Электрические печи - X304PIRNE (2.72 mb)
Электрические печи - X304PIRVE (2.72 mb)