Войти:
Оценок - 4, средний балл: 3.5 ( )

Инструкция по эксплуатации APC, модель 2200XLT

Производитель: APC
Размер: 437.4 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Slide the UPS into position. Attach the Mounting Brackets to the Rack Use the ornamental screws supplied with the UPS to attach the mounting brackets to the rack post. Rack Mount Options Accessory receptacle plates are available for the 3000 VA model. These plates offer different receptacle configurations and hard wire installation. Contact your dealer or the factory at the number listed in APC Contact Information, page 21. 990-7031D, Revision 5 5/01 4 5 990-7031D, Revision 5 5/01 2. Connect the Batteries Note: All UPSs ship with the batteries disconnected. In addition, 5000 VA units have the batteries shipped outside the UPS case so you must install the batteries before connecting them. If you need to ship the UPS you must disconnect the batteries prior to shipment in order to comply with U.S. Federal Regulations. Refer to Appendix C: Transporting Your Smart-UPS, page 27, for details. Graphics are not drawn to scale. They are shown for reference only. Tower Units 5000 VA 1. Grasp the top edge of the bottom front cover and tilt it out. For 5000 VA units: Remove the front bezel by grasping the finger clips on the side of the bezel and carefully loosening the four (4) snaps. Skip to step 3. 2. Unhook the bottom section of the front cover from the chassis and set it aside. 3. Use a screwdriver or a coin to remove the two (2) battery door screws and open the door. 4. For 1400 – 3000 VA units: To connect the battery (or set), press the gray connector into the plug at the top of the battery housing. Note: The 5000 VA model has four (4) battery packs that must be installed. Be careful lifting the batteries - they are heavy. Support the bottom of the batteries as you move them. 5. For 5000 VA units: Hold the battery pack so that the leads are on top. Slide the battery pack into the UPS. Press the gray connector into the plug at the top of the battery compartment. Tuck the white cord (that serves as a handle for the connector) neatly to the side. 6. For 5000 VA units, repeat step 5 for the remaining three (3) battery packs. 7. Close the battery door, replace the screws, and replace the lower front cover. 990-7031D, Revision 5 5/01 6 3U Rack Mount Units 1. Reach into the finger pull and open the front cover. Swing the cover open as shown. 2. Unhook the side of the cover from the chassis and lift it away to expose the battery door. 3. Use a flat-blade or Phillips screwdriver or a coin to remove the two battery door screws and open the door. 4. Connect the battery leads to the battery. Connect the red wire to the positive (+) terminal and the black wire to the negative (–) terminal. 5. Close the battery door, replace the battery compartment screws, and replace the front cover. 5U Rack Mount Units 5000 VA 1. Reach into the finger pull and open the front cover. Swing the cover open as shown. For 5000 VA units: Remove the front bezel by grasping the finger clips on the side of the bezel and carefully loosening the four (4) snaps. Skip to step 3. 2. Unhook the side of the cover from the chassis and lift it away to expose the battery door. 5000 VA 3. Use a screwdriver or a coin to remove the two (2) battery door screws and open the door. 5000 VA 4. To connect the battery (or set), press the gray connector into the plug at the top of the battery housing. Note: The 5000 VA model has four (4) battery packs that must be installed. Be careful lifting the batteries - they are heavy. Support the bottom of the batteries as you move them. 5. For 5000 VA units: Hold the battery pack so that the leads are on the right hand side. Slide the battery pack into the UPS. Press the gray connector into the plug at the right-hand side of the battery compartment. Tuck the white cord (that serves as a handle for the connector) neatly to the side. 6. For 5000 VA units, repeat step 5 for the remaining three (3) battery packs. 7. Close the battery door, replace the screws, and replace the front cover. 7 990-7031D, Revision 5 5/01 3. Connect Power and Equipment to the UPS · Connect the UPS line cord (L6-30 plug) into the electrical outlet. · Use your equipment’s power cords to connect to the UPS. Caution: DO NOT use a standard serial interface cable to connect to the Computer Interface Port on the UPS. Standard serial interface cables are incompatible with the UPS connector. Use the cable provided with your UPS. · Turn on all connected equipment. 4. Connect Power to the UPS and Accessories · Press the UPS’s ON switch to turn on your UPS. This will power-up connected equipment. · The unit performs a self-test automatically when turned on, and every two weeks thereafter. · The UPS charges its battery whenever it is connected to utility power. The battery charges fully during the first four hours of normal operation. Do not expect full runtime during this initial charge period. 5. Install PowerChute and Accessories Note: This UPS is equipped with a SmartSlot for accessories. See the APC Website (for available accessories. If a standard ac...

Эта инструкция также подходит к моделям:
Источники питания и БП - 5000T (437.4 kb)
Источники питания и БП - 3000T (437.4 kb)
Источники питания и БП - 1400XLT (437.4 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории