Инструкция по эксплуатации APC, модель 1400XLT

Производитель: APC
Размер: 437.4 kb
Название файла: 990-7031D_REV05eng.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


4. Connect Power to the UPS and Accessories · Press the UPS’s ON switch to turn on your UPS. This will power-up connected equipment. · The unit performs a self-test automatically when turned on, and every two weeks thereafter. · The UPS charges its battery whenever it is connected to utility power. The battery charges fully during the first four hours of normal operation. Do not expect full runtime during this initial charge period. 5. Install PowerChute and Accessories Note: This UPS is equipped with a SmartSlot for accessories. See the APC Website (for available accessories. If a standard accessory is installed in this UPS, a User’s Manual for the accessory is included in the package. For additional comp uter system security, install PowerChute UPS monitoring software. It provides automatic unattended shutdown capabilities on most major network operating systems. Once PowerChute is loaded, install the PowerChute® black communication cable between UPS and computer. See the Software Installation: Instruction Sheet for details. Initial Startup Rear Views 1400 VA - 3000 VA Tower Models 1400 VA Rack Mount Model (5U) 2200 VA & 3000 VA Rack Mount Model (3U) Rack Mount Model (X136 Option) 5000 VA Tower Model 5000 VA Rack Mount Model Charge the battery The UPS charges its battery whenever it is connected to utility power. The battery will charge fully during the first four hours of normal operation. Do not expect full runtime during this initial charge period. Connect Computer Interface Port (Optional) Power management software and interface kits can be used with this UPS. Use only kits supplied or approved by the manufacturer. If used, connect the interface cable to the 9-pin computer interface port on the back panel of the UPS. Secure the connector’s screws to complete the connection. Caution: DO NOT use a standard serial interface cable to connect to the Computer Interface Port on the UPS. Standard serial interface cables are incompatible with the UPS connector. Use the cable provided with your UPS. Connect Ground Leads to TVSS Connector (Optional) The UPS features a TVSS connector for connecting the ground lead on transient voltage surge-suppression (TVSS) devices such as telephone and network line protectors. The TVSS connector provides grounding through the UPS’s power cord ground conductor. To make a connection to the TVSS connector, loosen the screw and connect the surge suppression device’s ground lead. Tighten the screw to secure the lead. Battery Pack Connector (Optional) Use the battery pack connector (on units that have one) to connect the optional external battery pack. See Appendix A: XL Information, page 23, for instructions. Voltage Sensitivity The UPS detects line voltage distortions such as spikes, notches, dips, and swells, as well as distortions caused by operation with inexpensive fuel-powered generators. By default, the UPS reacts to distortions by transferring to on-battery operation to protect the loads. Where power quality is poor, the UPS may frequently transfer to on-battery operation. If the loads can operate normally under such conditions, battery capacity and service life may be conserved by reducing the sensitivity of the UPS. To reduce UPS sensitivity, press the configuration button on the rear panel. Use a pointed object such as a pen to press the button. Press it once to set the UPS’s sensitivity to reduced. Press it again to set the sensitivity to low. Press the button a third time to reset normal sensitivity. normal When the UPS is set to normal sensitivity, the configuration LED is brightly lit. reduced When it is set to reduced sensitivity, the LED is dimly lit. low When it is set to low sensitivity, the LED is off. Low Battery Warning Interval By default, the low battery warning occurs when there are approximately two minutes of on-battery run time remaining. This may not be enough time to gracefully shut down some protected computer systems. To change the warning interval, press the rear panel configuration button while pressing and holding the front-panel on/test button. 2 min. When the LED is brightly lit, the low battery warning interval is roughly 2 minutes. This is the initial setting. 5 min. When the LED is dimly lit, the low battery warning interval to approximately five minutes. 7 min. When the LED is off, the low battery warning interval is approximately seven minutes. Press the button a third time to reset the interval to two minutes. Operating Instructions Switch On — Switch Off 990-7031D, Revision 5 5/01 8 With the UPS plugged in, press and release the large upper on/test button to supply power to the loads. The loads are immediately powered while the UPS beeps and performs a self-test. Press and release the small, lower off button to turn off power to the loads. It may be convenient to use the UPS as a master on/off switch for the protected equipment. Note: Whenever the UPS is plugged in and utility voltage is present, the charger maintains batter...

Эта инструкция также подходит к моделям:
Источники питания и БП - 5000T (437.4 kb)
Источники питания и БП - 3000T (437.4 kb)
Источники питания и БП - 2200XLT (437.4 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории