Войти:

Johnson Controls R-410A

Скачали: 2Размер: 4 mb    Производитель: Johnson Controls  
Категория: Насосное оборудование

Each unit is pressurized with a holding charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation make these condensing units and heat pumps suitable for almost any outdoor location. On rooftops... because they weigh much less than a single package unit of similar capacity and are much easier to rig and support. On the ground... because the footprint is compact allowing a variety of applications. Both the UP condensing units

Johnson Controls ALL RESIDENTIAL MULTI-POSITION 356486-UUM-H-0609

Скачали: 0Размер: 2 mb    Производитель: Johnson Controls  
Категория: Электрообогреватели

TABLE OF CONTACT INFORMATION ...............................1 SAFETY................................................1 INSTRUCTIONS FOR EXAMINING THE FURNACE INSTALLATION ................................2 START-UP AND SHUTDOWN INSTRUCTIONS ................3 HOW YOUR GAS FURNACE WORKS ......................3 OPERATING INSTRUCTIONS.............................4 TO TURN OFF THE APPLIANCE ..........................4 FURNACE MAINTENANCE - USER INFORMATION ............4 EXTERNAL AIR FILTERS

Johnson Controls 356486-UUM-E-0109

Скачали: 0Размер: 2 mb    Производитель: Johnson Controls  
Категория: Электрообогреватели

When you see this symbol on labels or in manuals, be alert to the potential for personal injury. Understand and pay particular attention to the signal words DANGER, WARNING, or CAUTION. DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation, which, if not avoided may

Johnson Controls LP8C/LPLC*MP

Скачали: 3Размер: 2 mb    Производитель: Johnson Controls  
Категория: Электрообогреватели

ID MODELS LO COMP Single Stage Compressor (OUT) O Reversing Valve Energized in Cool HI COMP Second Stage Compressor (OUT) TWO STAGE AIR CONDITIONER C 24 – Volt Common R 24 – Volt Hot Y1 First Stage Compressor Y2 Second Stage Compressor External Humidistat (Optional) Open on Humidity Rise 2 Part Number: S1-2HU16700124 2 TP(8,L)C YP(8,L)C CP(8,L)C LP(8,L)C FIGURE 21: Thermostat Chart - Two Stage Air Conditioner with Single Stage Thermostat – Variable Speed or PSC Modulating Furnace Johnson Control

Johnson Controls CP8C/CPLC*MP

Скачали: 32Размер: 2 mb    Производитель: Johnson Controls  
Категория: Электрообогреватели

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 START-UP AND ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . 22 DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 SAFETY CONTROLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 NORMAL OPERATION AND DIAGNOSTICS . . . . . . . . . . . . . 29 GAS PIPING . . .

Johnson Controls SA PC090 THRU 240

Скачали: 40Размер: 2 mb    Производитель: Johnson Controls  
Категория: Кондиционеры

. Heating Sequence of Operation . . Unit Control Board Option Setup. . Troubleshooting ................ Typical Wiring Diagrams .......... . 9 10 17 17 17 18 18 18 20 23 23 30 LIST OF TABLES 1 PC090 - 240 and PD180 - 240 Physical Data........ . . 4 7 PC090, PC120 Unit Height Dimensions........... . . 15 2 Unit Application Data........ . . 5 8 PC/PD180 & PC/PD240 Unit Height Dimensions. . . . . . 16 3 Corner Weights & Center of Gravity............... . . 6 9 Piping and Electrical Conn

Johnson Controls SA PD 180 THRU 240

Скачали: 16Размер: 2 mb    Производитель: Johnson Controls  
Категория: Кондиционеры

An anti-short cycle delay (ASCD) is utilized to prevent operation of a compressor too soon after its previous run. The ASCD is initiated on unit start-up and on any compressor reset or lockout. The Simplicity™ control board monitors the following inputs for each cooling system: • A high-pressure switch is factory installed to protect against excessive discharge pressure due to a blocked condenser coil or a condenser fan motor failure. During cooling operation, if a high-pressure limit switch o

Johnson Controls GG9S*MP

Скачали: 1Размер: 2 mb    Производитель: Johnson Controls  
Категория: Электрообогреватели

. .24 Double Vertical Combustion Air Intake and Vent Termination .....24 Direct Vent Air Intake Connection and Vent Connection .........25 Combustion Airflow Path Through The Furnace Casing .........25 Outside and Ambient Combustion Air........................26 Attic and Crawl Space Combustion Air Termination .............27 Gas Valve.............................................30 Reading Gas Pressure...................................30 Furnace Control Board............................

Johnson Controls TG9S*MP

Скачали: 0Размер: 2 mb    Производитель: Johnson Controls  
Категория: Электрообогреватели

The equivalent length of the vent system is the total length of straight pipe PLUS the equivalent length of all of the elbows. The following rules must also be followed: 1. Long radius (sweep) elbows are recommended. Standard elbows may be used, but since they have a longer equivalent length, they will reduce the total length of pipe that will be allowed. Short radius (plumbing vent) elbows are not allowed. The standard dimensions of the acceptable elbows are shown below. 2. The maximum equiv

Johnson Controls CM8M/CMLM*MP

Скачали: 3Размер: 2 mb    Производитель: Johnson Controls  
Категория: Электрообогреватели

LO COMP Single Stage Compressor (OUT) O Reversing Valve Energized in Cool HI COMP Second Stage Compressor (OUT) Change Hot Heat Pump jumper on the heat pump control to “ON” if Hot Heat Pump Operation is desired. External Humidistat (Optional) Open on Humidity Rise 3 ID MODELS TM(8,L)M YM(8,L)M CM(8,L)M LM(8,L)M FIGURE 25: Thermostat Chart - Two Stage Heat Pump – Variable Speed or PSC Modulating Furnace Johnson Controls Unitary Products 368261-UIM-A-0508 18 Johnson Controls Unitary Products ACCES





Категории