Войти:

Aprilaire MR850

Скачали: 21Размер: 4 mb    Производитель: Aprilaire  
Категория: Увлажнители воздуха

Heater plate triac circuit faulty. E30 Power (on/off) button stuck on E31 Mute button stuck on E32 Mode button stuck on E40 Unit not functional tested at time of manufacture MR850 Technical Manual * Revision J * Issued November 2005 * Ref. 185041340 (185041713 internal) Error Description of Fault E41 Failed the functional test at time of manufacture E42 Was not stress tested during manufacture E43 Failed the stress test during manufacture E44 Not tested on functional tester 2 E45 Failed producti

Aprilaire 1160

Скачали: 0Размер: 2 mb    Производитель: Aprilaire  
Категория: Увлажнители воздуха

................................................................................................................................................................................ AIRFLOW PROVING SWITCH INSTALLATION INSTRUCTIONS Description: FIGURE 20 The airflow proving switch is a safety device that will prevent the humidifier from producing steam when there is no airflow present in the HVAC system. The switch is a pressure differential measuring device that determines if there is airflow present

Aprilaire 1150

Скачали: 0Размер: 2 mb    Производитель: Aprilaire  
Категория: Увлажнители воздуха

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Materials Provided and Not Provided . . . . . . . . . . . . . . . . . . 3 Electrical Specifications, Capacities and Weights . . . . . . . . 4 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Overview of Humidifier Operation . . . . . . . . . . . . . . . . . . . . . 7 INSTALLATION Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Setting Slide Switches. . . . . .

Aprilaire 8400

Скачали: 5Размер: 1 mb    Производитель: Aprilaire  
Категория: Термостаты

61000651B 8400 Tstat Owners.indd 3 7/23/09 10:43:02 AM AbOUT yOUR NEw THERmOSTAT – NON-pROgRAmmAblE mODElS AbOUT yOUR NEw THERmOSTAT – NON-pROgRAmmAblE mODElS CONTROlS & DISplAy OVERVIEw – mODElS 8444, 8446, 8448 CURRENT INDOOR TEMPERATURE SySTEM MODE SETTINg SySTEM MODE (PAgE 6) FAN SETTINg (PAgE 7) FAN SETTINg BATTERy DOOR OUTDOOR TEMPERATURE (OPTIONAL) TEMPERATURE SETTINg EQUIPMENT STATUS UP DOWN HEAT pUmp mODElS ONly EMERgENCy HEAT (RED) SySTEM FAULT (yELLOW) INDICATOR SHOWS THROUgH HOUSINg

Aprilaire 4300

Скачали: 0Размер: 1 mb    Производитель: Aprilaire  
Категория: Воздухоочистители

The largest of these particles will eventually come to rest and appear as dust. Smaller particles may come to rest, but with even the slightest disturbance will re-suspend into the air. These particles are very small, and come from natural sources such as dust and pollen and from manmade sources such as tobacco smoke or exhaust. The air cleaner is installed on or near the furnace/air handler and removes the particles that travel with the air that circulates through your heating and cooling syste

Aprilaire 8800 UNIVERSAL

Скачали: 19Размер: 1 mb    Производитель: Aprilaire  
Категория: Термостаты

Model 8800 Universal Communicating Thermostat Model 8800 Universal Communicating Thermostat Owner’s Manual Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS 61000762A 8800 Tstat Owners.indd 1 3/28/11 4:19:57 PM TAblE Of CONTENTS TAblE Of CONTENTS AbOUT yOUR NEw THERMOSTAT Thermostat features 3 Controls & display overview 4-5 OpERATION Select system mode (HEAT/COOL) 6 Change temperature set point 6 Select fan setting (ON/AUTO/CIRC) 7 Clean screen 7 Maintena

Aprilaire MR700

Скачали: 2Размер: 1 mb    Производитель: Aprilaire  
Категория: Увлажнители воздуха

Otherwise if a heater wire is not connected then the optoisolator will be turned on and off in synchronisation with the secondary cycle. The output of the optoisolator feeds U4 on the control board. This signal, with processor interpretation, provides the information to determine if the Heater Wire is connected or open circuit and also the integrity of fuse F2, the 4 A fuse supplying power to the Heater Wire. Q11 controls power to the heaterplate and is under control of optoisolator U12 and tran

Aprilaire MR480

Скачали: 0Размер: 1 mb    Производитель: Aprilaire  
Категория: Увлажнители воздуха

25 8.6 Circuit Diagrams - Revision H and J PCB Power PCB ...................................................................................................... 26 8.7 Circuit Diagrams - Revision F PCB Control PCB..............................................................................................................27 8.8 Circuit Diagrams - Revision F PCB Power PCB ................................................................................................................ 28 8.9 Electri

Aprilaire MR720

Скачали: 0Размер: 1 mb    Производитель: Aprilaire  
Категория: Увлажнители воздуха

Ceramic 22 nF 50 V.............................................................................. 312040116 C22, C23 Cap. Mylar 10 nF 50 V................................................................................. 316040084 C21, C24 Cap. Ceramic 470 pF 50 V............................................................................ 312040118 D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12 Diode 1N4148.........................................................................................

Aprilaire MR730

Скачали: 6Размер: 1 mb    Производитель: Aprilaire  
Категория: Увлажнители воздуха

• To upgrade both PCBs and the software use a PCB service upgrade kit. The part numbers to order are as follows: Model Part number Model Part number MR480 043040791 MR720 043040793 MR700 043040792 MR730 043040794 • For humidifiers with Rev F or later PCBs, you will only be required to purchase individual boards for repairs (as detailed in sect. 8.9). • If a revision H or later power PCB needs replacing, the replacement power PCB must also be revision H or later. Replacing revision F or earlier p





Категории