Войти:
Скачали: 0   Размер: 7 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

30. Indoor Air Quality (CO2) Room Sensor (EconoMi$er IV: Sensor shall have the ability to provide demand ventilation control through the EconoMi$er IV. The IAQ sensor shall be wall mounted with an LED display in parts per million. The set point shall have adjustment capability. 31. Return Air CO2 Sensor (EconoMi$er IV): Sensor shall have the ability to provide demand ventilation control through the EconoMi$er IV. The IAQ sensor shall be duct mounted. The set point shall have adjustment capabilit

Скачали: 0   Размер: 7 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

*Motor drive range: 830 to 1130 rpm. All other rpms require field-supplieddrive. 580F036- 151 71 580F036 151 580F036 151 PERFORMANCE DATA (cont) FAN PERFORMANCE — HORIZONTAL DISCHARGE UNITS (cont) 580F150,151 (121/2 TONS) — STANDARD MOTOR (BELT DRIVE)* Airflow (Cfm) External Static Pressure (in. wg) 0.2 0.4 0.6 0.8 1.0 Rpm Bhp Watts Rpm Bhp Watts Rpm Bhp Watts Rpm Bhp Watts Rpm Bhp Watts 3700 676 1.19 1106 747 1.42 1328 811 1.66 1552 871 1.91 1779 927 2.15 2008 3800 690 1.27 1185 760 1.52 1414 8

Скачали: 0   Размер: 7 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

H. Filter Section: 1. Standard filter section shall consist of factory- installed, low velocity, throwaway 2-in. thick fiberglass filters of commercially available sizes. 2. Filter face velocity shall not exceed 320 fpm at nominal airflows. 3. Filter section should use only one size filter. 4. Filters shall be accessible through an access panel with “no-tool” removal. I. Controls and Safeties: 1. Unit Controls: Unit shall be complete with self-contained low-voltage control circuit protected by a

Скачали: 1   Размер: 7 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

Copper Tubes, Aluminum Lanced, AluminumPre Coated, or Copper Plate Fins Rows...Fins/in. Total Face Area (sq ft) EVAPORATOR FAN Quantity...Size (in.) Type Drive Nominal Cfm Std Motor Hp Opt Motor Hp Motor Nominal Rpm Std Maximum Continuous Bhp Opt Maximum Continuous Bhp Motor Frame Size Fan Rpm Range Low-Medium Static High Static Motor Bearing Type Maximum Allowable Rpm Motor Pulley Pitch Dia. Low-Medium Static High Static Nominal Motor Shaft Diameter (in.) Fan Pulley Pitch Diameter (in.) Low-Med

Скачали: 1   Размер: 4 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

7267627267627275TC183.66166.86151.43194.90177.83162.05201.97SHC79.39100.52121.9191.70119.42147.05102.94kW9.829.639.469.589.769.9610.0485TC172.71156.78142.09183.32167.13152.17189.98SHC69.0390.92112.9580.69109.17137.5191.49kW10.8210.6310.4510.5710.7610.9611.0495TC161.37146.24132.38171.36156.04141.86177.62SHC58.4481.04103.7769.4298.67127.7179.83kW11.9211.7311.5611.6811.8612.0512.14 105TC149.57135.32122.21158.89144.45131.10164.74SHC47.5770.9294.3257.8587.91117.6167.79kW13.1212.9412.7712.8913.0613.24

Скачали: 1   Размер: 3 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

1). 2. Be sure the installation conforms to all applicable local and national codes. 3. These instructions contain important information for the proper maintenance and repair of this equipment. Retain these instructions for future use. CONTENTS Page SAFETY CONSIDERATIONS ...................... 1,2 INSTALLATION.................................2-14 I. Locate the Unit............................ 2 II. Unit Duct Connections...................... 9 III. Rig and Place Unit ...................

Скачали: 0   Размер: 2 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

FEATURES/BENEFITS • Efficient rooftop line for cooling using scroll compressor technology • Efficient rooftop line for heating using dimpled heat exchangers • High reliability — non-corrosive condensate pans, prepainted cabinets and primed interior panels, and all units are fully protected by internal safeties • Quiet operation — isolated compressor plate. All compressors mounted on independent vibration isolators. Standard, belt-driven evaporator fan motors on all units • Ease of maintenance ac

Скачали: 0   Размер: 2 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

Bhp — Brake Horsepower NOTE: Maximum continuous bhp for the standard motor is 6.13. The Watts — Input Watts to Motor maximum continuous watts is 5180. Do not adjust motor rpm such that motor maximum bhp and/or watts is exceeded at the maximum operat *Standard low-medium static drive range is 873 to 1021 rpm. Alternate ing cfm. See Table 24 for more information. high-static drive range is 1025 to 1200. Other rpms require a field- supplied drive. —27— Table 14 — Fan Performance — 580F180360 (High

Скачали: 0   Размер: 2 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

For propane operation, conversion kit P/N 301625-703 must be field-installed. Model 585B units have two A.G.A.-certified heating input ratings. See Table I. These units are designed for outdoor installation either on a rooftop or at ground level on a slab. The cooling section is factory-charged and sealed, minimizing installation time. Installation is easy—connect gas supply, air ducts, condensate drain, high- and low-voltage wiring, and install the air filter. NOTE: An optional condenser coi

Скачали: 0   Размер: 2 mb   Производитель: Bryant  
Категория: Газовые нагреватели
@name

Instructions continued on page 8. —3— NOTES: 1. Dimensions in ( ) are in millimeters. 2. Refer to Fig. 4 and 5 for unit operating weights. 3. Remove boards at ends of unit and runners prior to rigging. 4. Rig by inserting hooks into unit base rails as shown. Use corner post from packaging to protect coil from damage. Use bumper boards for spreader bars on all units. 5. Weights do not include optional EconoMi$erIV. Add 90 lb (41 kg) for EconoMi$erIV weight. 6. Weights given are for aluminum evapo