Инструкция по эксплуатации Bryant, модель 585B

Производитель: Bryant
Размер: 1.82 mb
Название файла: 39585dp26-b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


For propane operation, conversion kit P/N 301625-703 must be field-installed. Model 585B units have two A.G.A.-certified heating input ratings. See Table I. These units are designed for outdoor installation either on a rooftop or at ground level on a slab. The cooling section is factory-charged and sealed, minimizing installation time. Installation is easy—connect gas supply, air ducts, condensate drain, high- and low-voltage wiring, and install the air filter. NOTE: An optional condenser coil grille is available for field installation. See Figure 1. A full line of rooftop system accessories are available for field installation. These accessories include plenums with factory-supplied high-capacity filter and outside air intake hood, unitized curbs, economizers (both downflow and horizontal), barometric relief dampers, concentric diffuser box assemblies, flexible duct packages, and high-capacity filter racks with filters. When installing these accessories, see Installation Instructions packaged with them. Important—Read Before Installing 1. Check all local or other applicable codes for information concerning proximity to property lines, height above roof, obstructions, etc. 2. Make certain power supply available (volts, hertz, and phase) corresponds to that specified on unit rating plate. 3. Check electrical supply provided by utility to be sure that service capacity is sufficient to handle load imposed by this unit. 4. Locate the unit where the vent cap is a minimum of 4 feet from openable windows or doors. 5. The installation must conform with local building codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1. GENERAL The condensing section has been designed and tested in accordance with ARI 210. The appliance design is certified by American Gas Association for use with natural or propane gases with appropriate controls and orifices. Installation of the unit consists of the following: I. Moving and Setting Unit In Place II. Venting III. Gas Piping Cancels: 39585DP26-A 39585DP26-B 7/15/79 A77017 Figure 1—Sizes 024075, 030075, & 036075 With Optional Condenser Coil Grille Installed IV. Duct Connections V. Electrical Connections VI. Preparing Unit for Startup VII. Heating Startup and Adjustments VIII. Cooling Startup and Adjustments IX. Care and Maintenance I. MOVING AND SETTING UNIT IN PLACE CAUTION: Be sure to protect the top and sides of the unit when rigging the unit to be lifted. See Figure 4. Extreme caution should be used to prevent damage when moving the unit. The unit should remain in an upright position during all rigging and moving operations. To facilitate lifting and moving, place the unit in an adequate rope or cable sling. A. Rooftop Installation Place the unit on a level base. See Figures 8 and 9 for typical installations. On flat roofs, be sure that the unit is at least 4 inches above the roof to prevent flooding. Consult local codes for installation requirements. Be sure the roof will support the additional weight. See Figure 2 for weight information. NOTE: See the Installation Instructions packaged with the accessory plenum and unitized curb when these system accessories are being installed. B. Ground Level Installation CAUTION: Unit must be mounted level for proper condensate drainage. Place the unit on a level concrete slab that is a minimum of BDP Company, Division of Carrier Corp. DIMENSIONS (Inches) Size A B D E F G H J 018050 & 024050 44-5/8 30-3/8 16 10 — 1-1/8 16 7-1/4 024075, 030075, & 036075 44-5/8 40-3/8 19 10 _ 1-3/8 13-1/4 8-7/8 036125, 042100, & 048125 58-5/8 44-5/8 24 14 _ 1-3/8 13-1/4 8-7/8 060125 & 060150 66-7/8 44-5/8 32 10 15-3/4 1-3/8 13-1/4 8-7/8 Zi -tf- -V- F—REAR VIEW WEIGHT DISTRIBUTION tLECTRlCAl DISCONNECT MAY BE MOUNTED ON THIS PANEL blower access DUOR CONTROLS ACCESS DOOR -l-v> i_T CONDLNScR FAN TOP VIEW LEFT-SIDE VIEW ? KIGH-VOLTAGE COMPRESSOR / ^ . INLET ACCESS DOOR / £t FRONT VIEW |fpt drain 4 CONNECTION A76216 Size Shipping Wt (lbs) Operating Wt (lbs) Corner Wt (lbs) A B C D 018050 325 300 77 75 73 75 024050 330 305 86 83 66 70 024075 425 395 115 110 83 87 030075 430 400 116 111 84 89 036075 440 405 117 112 85 91 036125 510 465 132 126 101 106 042100 520 475 136 129 103 107 048125 535 490 150 143 96 101 060125 600 550 142 136 132 140 060150 615 565 144 138 137 146 D C Figure 2—Model 585B Dimensional Drawing, Shipping Weights, Operating Weights, & Weight Distribution TABLE I-585B RATINGS & RECOMMENDED FILTER SIZES A B A77083 SIZE 018050 024050 024075 030075 036075 036125 042100 048125 060125 060150 Rated Cooling Capacity (Btuh)* 18,500 23,000 24,000 29,000 37,000 35,500 42,000 47,000 59,000 59,000 Rated Cooling Airflow (Ft3/Min)* 690 850 900 1000 1200 1300 1550 1600 2200 2200 Rated,Maximum External Static Pressure Single-Phase Units (In. wc) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Three-Phase Units (In. wc) — — — — 0.65 0.65 0.65 0.65 0.65 ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории