Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Empire Comfort Systems, модель UNVENTED GAS LOG HEATER VFDT18LBN-1

Производитель: Empire Comfort Systems
Размер: 3.61 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


A vented decorative appliance must be installed only in a solid- fuel burning fireplace with a working flue and constructed of noncombustible material. Any alteration of the original design, installed other than as shownintheseinstructionsorusewithatypeofgasnotshownon the rating plate is the responsibility of the person and company making the change. Important All correspondence should refer to complete Model Number, Serial Number and type of gas. Attention: During initial use of log you will detect an odor as the log is cured. Notice: During initial firing of this unit, its paint will bake out, and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed. WARNING: This appliance is for installation only in a solid- fuel burning masonry orUL127 factory-built fireplace orin a listedventlessfireboxenclosure.Ithasbeendesigncertifiedfor these installations. Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs. WARNING: Any modification to this unvented gas heater or its controls can be dangerous. Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning. Well Head Gas Installations Some natural gas utilities use "well head" gas. This may affect the Btu output of the unit. Contact the gas company for the heating value. Contact the manufacturer or your gas company before changing spud/orifice size. ACCESSORIES for VFDR, VFDT, & VFDM EK-1 PE-20 ELH-1 ELH-2 Description Embers Kit Platinum Embers Fireplace Hood for Vent-Free Logs Fireplace Hood for Vent-Free Logs Color Black Brass FRBC ACCESBattery Operated Remote Control SORIES for VFDR ONLY FRBTC Battery Operated Remote Control with Thermostat FREC Electric Remote Control FWS Wall Switch TRW Remote Wall Thermostat TMV Wall Thermostat, Millivolt - Reed Switch 23099-1-0707 Page 5 PRODUCT SPECIFICATIONS Model Gas Valve Type Regulator Pressure Setting Gas Inlet Pressure Max Gas Inlet Pressure Minimum VFDR(18,24,30)LB Natural Millivolt 3.5" W.C. 10.5" W.C. 4.5" W.C. Propane 10.0" W.C. 13.0" W.C. 11.0" W.C. VFDR18LB10 Natural Millivolt 3.5" W.C. 10.5" W.C. 5.0" W.C. Propane 10.0" W.C. 13.0" W.C. 11.0" W.C. VFDT(18,24,30)LB Natural Thermostat 6.0" W.C. 10.5" W.C. 7.0" W.C. Propane 10.0" W.C. 13.0" W.C. 11.0" W.C. VFDM(18,24,30)LB Natural Manual 6.0" W.C. 10.5" W.C. 7.0" W.C. Propane 10.0" W.C. 13.0" W.C. 11.0" W.C. Model BTU/hr. Max. Rate BTU/hr. Med. Rate BTU/hr. Min. Rate VFDR18LB10N 10,000 N/A N/A VFDR18LB10P 10,000 N/A N/A VFDR18LBN 28,000 N/A 19,000 VFDR18LBP 28,000 N/A 22,000 VFDR24LBN 34,000 N/A 24,000 VFDR24LBP 34,000 N/A 26,000 VFDR30LBN 40,000 N/A 27,000 VFDR30LBP 40,000 N/A 31,000 VFDT18LBN 28,000 N/A 19,000 VFDT18LBP 28,000 N/A 22,000 VFDT24LBN 34,000 N/A 24,000 VFDT24LBP 34,000 N/A 26,000 VFDT30LBN 40,000 N/A 27,000 VFDT30LBP 40,000 N/A 31,000 VFDM18LBN 28,000 23,000 19,000 VFDM18LBP 28,000 25,000 22,000 VFDM24LBN 34,000 29,000 24,000 VFDM24LBP 34,000 30,000 26,000 VFDM30LBN 40,000 32,000 27,000 VFDM30LBP 40,000 36,000 31,000 WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather. The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source (an entire house). Page 6 23099-1-0707 GENERAL INFORMATION This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids. Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appliance. Water vapor produced by an unvented heater can create moisture problems in a home when operated for extended periods of time. During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. Thi...

Эта инструкция также подходит к моделям:
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM18LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM24LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM30LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDR18LB10N-1 (3.61 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории