Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Empire Comfort Systems, модель UNVENTED GAS LOG HEATER VFDR30LBP-1

Производитель: Empire Comfort Systems
Размер: 3.61 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 1. Set REMOTE/OFF/ON switch to OFF. 2. Turn off all electric power to the appliance if service is to be performed (if applicable). 3. Open bottom louver assembly (if applicable). 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close bottom louver assembly (if applicable). 1. STOP! Read the safety information above on this page. 2. Set REMOTE/OFF/ON switch to "OFF". 3. Turn off all electric power to the appliance (if applicable). 4. Open bottom louver assembly (if applicable). 5. Push in gas control knob slightly and turn clockwise to "OFF". NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 6. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. 7. Find pilot - Follow metal tube from gas control. The pilot is located next to the burner, near the right side. 8. Turn gas control knob counterclockwise to "PILOT". 9. Push in control knob all the way and hold in. Repeatedly push the Piezo Ignitor Button until the pilot is lit. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob, and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9. • If knob does not pop up when released, STOP and IMMEDIATELY call a qualified service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier. 10. Turn gas control knob counterclockwise to "ON". 11. Close bottom louver assembly (if applicable). 12. Turn on all electric power to the appliance (if applicable). 13. Set REMOTE/OFF/ON switch to desired setting. GAS CONTROL KNOB SHOWN IN "OFF" POSITION. THERMOCOUPLE (NATURAL) ELECTRODE PILOT THERMOPILE REMOTE OFF ON THERMOCOUPLE (LPG) GAS CONTROL KNOB SHOWN IN "OFF" POSITION. THERMOCOUPLE (NATURAL) ELECTRODE PILOT THERMOPILE REMOTE OFF ON THERMOCOUPLE (LPG) VFDR18LB10(N,P) LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE A. B. VFDT(18,24,30)LB LIGHTING INSTRUCTIONS WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. BEFORE LIGHTING,smellallaround theappliancearea for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance • Do not touch any electrical switch; Do not use any phone in your building • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in orturn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. FOR YOUR SAFETY READ BEFORE LIGHTING 1. 2. 3. 4. 5. 6. 7. 8. STOP! Read the safety information above on this page. Set thermostat (gas control knob) to lowest setting. Turn off all electric power to the appliance (if applicable). Push in gas control knob slightly and turn clockwise to "OFF." Do not force. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. Find pilot - the pilot is located in front of the rear log. Turn manual gas control knob counterclockwise to "PILOT." Push in manual gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit (or use a match to light). Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 though 8. • If knob does not pop up when released, stop and immediately callyou service technician or gas supplier • If the pilot will not stay lit after several tries, ...

Эта инструкция также подходит к моделям:
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM18LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM24LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM30LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDR18LB10N-1 (3.61 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории