|
Фрагмент инструкции
Fluffed up pieces one layer thick on top of the burner generally works best, and will provide the best ember glow. Do not place ember material more than one layer thick. No more than (2) two small packets of ember material (part no. 15998) evenly placed on the burner, is recommended on VFDR18 and VFDR24 models. Using additional ember material will decrease the amount of ember glow effect. Extra ember material should be saved for future ember applications as necessary. See Figure 13. Figure 12 WARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Attention: Do not use Figure 12 or Figure 13 to order logs. Refer to Parts Lists and Parts Views to order logs and/or ember material for your appropriate model. Figure 13 1 4 5 3 2 VFD(R,T,M)(18,24) & VFDR18LB10 LOG PLACEMENT (5 LOG SET) Description Part # VFD(R,T,M)18 Embers 15998 VFD(R,T,M)24 Embers 15998 VFD(R,T,M)30 Embers 15999 Platinum Bright Embers PE20-1 Note: A single layer of embers is to be used when applying Platinum Bright Embers (alone or in combination with stndard embers) to the burner. Page 14 23099-1-0707 Before you begin: If you are installing logs onto the VFD(R,T,M)30 model, this burner assembly place is supplied with a set of seven ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fiber. The positioning of logs is critical to safe and clean operation of this burner assembly. Sooting and other problems may result if the logs are not properly and firmly positioned on the burner assembly. Refer to Figure 14 and Figure 15 and corresponding WARNING: when completing following log placement steps. 1. Place front logs (#1, #2, and #3) between grates and main burner. Align notches on front logs with locator tabs in base. 2. Place middle log (#4) between front and rear loop of burner. Note: Do not place on top of pilot assembly. 3. Place rear log (#5) on rear log shelf. Bottom flange is to be placed between the log shelf and burner tube. 4. Place front twig (#6) onto flat areas of middle log (#4) and bottom end of front twig to the back side of the grate tang (4th one from the left). 5. Place the rear twig (#7) onto flat area of rear log (#5) and over the front of the front twig. Ember Material Placement on Burner 6. After all logs are properly positioned, place small "dime" size pieces of Rockwool lightly across the front burner tube ports. Place the ember material (Rockwool pieces) side by side. Do not stack more than one layer of embers across the burner ports. No more than (1) one packet of ember material (part number 15999) evenly placed on the burner, is recommended on VFDR30 models. See Figure 15. Figure 15 VFD(R,T,M)30 LOG PLACEMENT (7 LOG SET) Figure 14 1 2 3 4 6 5 7 EMBER MATERIAL PLACEMENT (SHADED AREA ONLY) Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Attention: Do not use Figure 14 or Figure 15 to order logs. Refer to Parts Lists and Parts Views to order logs and/or ember material. Description Part # VFD(R,T,M)18 Embers 15998 VFD(R,T,M)24 Embers 15998 VFD(R,T,M)30 Embers 15999 Platinum Bright Embers PE20-1 Note: A single layer of embers is to be used when applying Platinum Bright Embers (alone or in combination with stndard embers) to the burner. 23099-1-0707 Page 15 Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed. In normal operation at full rate, the flame appearance should be sets of yellow flames above the rear burner section, and shorter blue flames with glowing embers on the front burner section. NOTE: all flames will be random by design, flame height will go up and down. Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside the burner area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper burning will result. During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence. The initial break-in operation should last 2-3 hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight and will disappear with continued use. Millivolt Val...
Эта инструкция также подходит к моделям:Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM18LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM24LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDM30LBN-1 (3.61 mb)
Газовые нагреватели - UNVENTED GAS LOG HEATER VFDR18LB10N-1 (3.61 mb)