Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Invacare, модель Stratos Portable Plus Battery Pack IRC 1731

Производитель: Invacare
Размер: 718.7 kb
Название файла: 1150754B.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


- IRC 1731 SAVE THESE INSTRUCTIONS NOTE: Check all parts for shipping damage. In case of damage, DO NOT use. Contact the Carrier/ Invacare for further instruction. Safety Summary WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions, Stratos Portable Plus Compressor Operator’s Manual and any additional instructional material such as service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur. To charge battery, use only the original power cable (AC) or AC adapter and cable provided with your Stratos Portable Plus Compressor. Use of non-original equipment may result in damage to the battery. DO NOT dispose of battery pack in household waste. Proper disposal at an appropriate collection site in your local area is strongly recommended and may be required by some local ordinances. DO NOT dispose of batteries in fire, as they could explode. ACCESSORIES WARNING Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products. CAUTION DO NOT attempt to open the plastic case or replace any components. DO NOT short circuit battery contacts. Make sure battery contacts DO NOT come in contact with keys, coins or other metal objects. Charging of the battery requires at least six hours. Failure to condition the battery prior to its first use may result in a reduced battery life expectancy. The battery has protection from overheating and will not operate if temperature is 104°F (40°C) or higher. Allow the battery to cool before restarting. For more information regarding Invacare products, parts, and services, please visit Part No 1150754 1 STRATOS™Portable Plus Battery Pack Conditioning the Battery NOTE: The definition of conditioning the battery is simply charging the battery for a full six hour cycle before the initial use of the product. 1. Disconnect the battery from the compressor. 2. Connect the power cable (AC) or auto adapter cable (DC) to the battery. 3. Charge the battery for a full six hour cycle. The orange light will indicate if the battery is properly charging. Battery charging to full capacity is dependent upon many factors. Conditioning the battery requires at least 6 hours. Failure to condition the battery prior to its first use may result in a reduced battery life expectancy. To assure maximum life performance of the battery after conditioning, leave the battery connected to a power source when not in use. The battery operation time depends upon the charge condition of the battery, the temperature, the storage time of the battery prior to use, the amount of medication used for treatment, and the number of charge/discharge cycles. The manufacturer of the battery recommends the battery be conditioned every one or two months. Charging the Battery NOTE: For this procedure, refer to FIGURE 1. 1. Press in the release button on the front of the battery pack and separate the battery from the compressor (Detail “A”). 2. Connect the power cable (AC) to the AC adapter and cable provided with your STRATOS Portable Plus Compressor (Detail “B”). 3. Connect the AC adapter and cable to the battery (Detail “A”). 4. Plug the power cable into the appropriate power source. The ORANGE light will turn on indicating that the charging cycle has begun. The battery will reach full charge after at least sixhours.Completion ofthe chargecycle is indicated by a GREEN battery light. Full charge will provide up to ninety minutes of operation. NOTE: In order to ensure maximum performance of the battery, keep the battery plugged in and charging when not in use. This will not overcharge or damage the battery. NOTE: The battery must be plugged into a power source for the battery to charge. The battery will not charge when it is attached to the compressor nebulizer system. NOTE: Never leave the battery connected to either power cable when the cable is disconnected from the power source. This will cause the battery to discharge. Battery Hook Release DETAIL “A” - BATTERY Button Connect Adapter HERE DETAIL “B” Power ADAPTER Cable AC Adapter and Cable To Outlet To Battery FIGURE 1 Charging the Battery STRATOS™Portable Plus Battery Pack 2 Part No 1150754 Using the Battery 1. Before connecting the battery pack, shift the grey contacts cover located on the bottom of the compressor to the side, following the direction arrow. Refer to Contact Cover on page 3. FIGURE 2 Contact Cover 2. Fit the front hook on the battery top into the recess on the bottom of the compressor. Refer to Using the Battery on page 3. 3. Press the battery and c...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории