As each probe reaches the set point value, the display will indicate “DONE.” When all probes reach the individual set point value, the chiller will automatically convert to the holding mode for frozen product. WHEN IN THE HOLD TEMP MODE AFTER FREEZING BY PROBE: Press the RIGHTor LEFTarrow key to display the length of time it took for each probe to achieve set temperature. THESE DATA ARE RETAINED UNTIL A NEW PROBE CYCLE IS COMPLETED. QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 15. OPERATIONOPERATION HARD CHILL Starting from the OFF position, Press the START/STOP key. 3. 1. press the power key ON. The Display will require the operator to select The Alto-Shaam name will illuminate and the between chilling by PROBE or by TIME. SELECTION SCREEN will appear on the display. The compressor will become Select the desired Hard Chill method by energized and will begin to operate if required 4. pressing the rightor leftarrow keys. by the sensors. After the selection has been made, press the 2. Press the HARD CHILL key. START/STOP key. The display will indicate the last operator set internal compartment temperature. NOTE: MODIFIED COMPARTMENT TEMPERATURE IS NOT STORED OR SAVED UNTIL THE START BUTTON IS PRESSED TO BEGIN QUICKCHILLER OPERATION. To change the displayed temperature, press the up• or downarrow key to increase or decrease the temperature displayed within the parameters of the Hard Chill mode. QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 16. OPERATIONOPERATION HARD CHILL TIME If time was selected … The display will indicate the last period of time set by the operator. To change the displayed time, press the rightor leftarrow keys to select between hours or minutes and the upor downarrow key to increase or decrease the time. Press the START/STOP key. The Display will indicate the last set holding temperature. To change the displayed temperature press the upor downarrow key to increase or decrease the temperature display to any point within Quickchiller parameters for chilling product. After selections have been made, press the START/STOP key. The Quickchiller will begin operating in the Hard Chill “time” mode. When chilling by time, the display will indicate a count-down of the time, the air temperature, and the temperature of each food probe. After time has expired, the chiller will automatically convert to the set holding mode. PROBE If probe was selected … The display will indicate the last temperature set by the operator for each probe. To change the displayed probe temperature(s), press the rightor leftarrow keys to select each probe and the upor downarrow key to increase or decrease probe temperature. Press the START/STOP key. The Display will indicate the last set holding temperature. To change the displayed temperature press the upor downarrow key to increase or decrease the temperature display to any point within Quickchiller parameters for chilling product. After selections have been made, press the START/STOP key. The Quickchiller will begin operating in the Hard Chill “probe” mode. When chilling by probe, the display will indicate the length of time the product has been in the Hard Chill mode, the interior compartment set temperature, and the air temperature. The display will also indicate the temperature of each probe along with “ACT.” to advise the operator that the individual probe is active. As each probe reaches the set point value, the display will indicate “DONE.” When all probes reach the individual set point value, the chiller will automatically convert to the holding mode for chilled product. WHEN IN THE HOLD TEMP MODE AFTER HARD CHILLING BY PROBE: Press the RIGHTor LEFTarrow key to display the length of time it took for each probe to achieve set temperature. THESE DATA ARE RETAINED UNTIL A NEW PROBE CYCLE IS COMPLETED. QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 17. OPERATIONOPERATION SOFT CHILL Starting from the OFF position, Press the START/STOP key. 3. 1. press the power key ON. The Display will require the operator to select The Alto-Shaam name will illuminate and the between chilling by PROBE or by TIME. SELECTION SCREEN will appear on the display. The compressor will become Select the desired Soft Chill method by energized and will begin to operate if required 4. pressing the rightor leftarrow keys. After by the sensors. the selection has been made, press the 2. Press the SOFT CHILL key. START/STOP key. The display will indicate the last operator set internal compartment temperature. NOTE: MODIFIED COMPARTMENT TEMPERATURE IS NOT STORED OR SAVED UNTIL THE START BUTTON IS PRESSED TO BEGIN QUICKCHILLER OPERATION. To change the displayed temperature, press the up• or downarrow key to increase or decrease the temperature displayed within the parameters of the Soft Chill mode. QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 18. OPERATIONOPERATION SOFT CHILL TIME If time was selected … The display will indicate the last period of time set by the opera...
Эта инструкция также подходит к моделям:Холодильники - QC-100 (3.28 mb)
Холодильники - QC-100 REMOTE (3.28 mb)
Холодильники - QC-3 (3.28 mb)
Холодильники - QC-40 (3.28 mb)