Connecting a l120 mm exhaust-air pipe: . Attach the reducing connector directly to the air pipe. . Attach the exhaust-air pipe to the reducing connector. Prior to installation Preparing the ceiling . The ceiling must be flat and horizontal. . Ensure that the ceiling is capable of providing a firm hold for mounting screws and plugs. The enclosed plugs are suitable for concrete and stonework. If the ceiling is made of any other material, use appropriate mounting components. Weight in kg: Exhaust air Recirculating air 40,5 41,2 We reserve the right to construction changes within the context of technical development. Changing over from exhaust- air to recirculating mode Changing the electronic control system to recirculating mode: . The standard factory setting is for operation in exhaust-air mode. . To change the mode, the extractor hood must have been connected up and should be switched off. 0 1. Press and hold the 0 and 0 button. 2. While { is displayed, press the + button until a is displayed. When this has taken place, release the buttons. . a goes out shortly afterwards. The electronic control system will then have been set to recirculating mode. . By repeating steps 1 and 2, you can change the electronic control system back to exhaust-air mode (# in display). Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly above the chimney panelling in the ceiling. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user. This extractor hood corresponds to EC regulations concerning RF interference suppression. Installation The extractor hood is designed to be fitted to the kitchen ceiling or a rigid suspended ceiling. Ensure that the minimum distance between hotplate and extractor hood is 550 mm for electric hotplates and 650 mm for gas hotplates. 1. Mark the centre point of the extractor hood on the ceiling. 2. Using the template, mark screw positions on the ceiling. 3. Drill 4x 8 mm holes and insert wall plugs flush with the ceiling. 4. Determine the overall height of the support frame. – This is the height of the ceiling, the height of the base and the distance between the hob and extractor hood. Exhaust air 430 -710 Circulating air 430 -750 min. 550 electric 650 gas 29 Installation 08. Insert the extractor hood over the installation aids on the support frame. 5. Screw together the upper and lower sections of the support frame at the specified overall height with 8 screws. 10. Align the extractor hood. To do this, loosen the ceiling screws in the support frame. 09. Screw the extractor hood to the support frame and screw back the panel. 6. Screw the support frame to the ceiling with 4 screws. 7. Remove the panel. Exhaust air 430 – 710 Circulating air 430 – 750 Installation 11. Connect the pipes. 12. Connect the power. 13. Carefully remove the protective foil. 14. Place the two sections of the upper flue on the extractor hood and clip together. Protect the extractor hood from damage. 15. Push up the upper flue section and screw into position. 16. Insert the two sections of the lower flue and clip together. Protect the extractor hood from damage. Mode d’emploi: Description de l'appareil Eclairage Grille du filtre Capot de cheminee Commutateur Lumiere/ Ventilateur Modes de fonctionnement Air evacue a l'exterieur: . Le ventilateur de la hotte aspire les buees de cuisson qui traversent un filtre a graisse avant de regagner l'atmosphere exterieur...

Эта инструкция также подходит к моделям:
Вытяжки - DIE165E/01 (4.29 mb)
Вытяжки - DIE165R/01 (4.29 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории