Cleaning the metal grease filters: • In normal operation (1 to 2 hours daily), the metal grease filter must be cleaned 1 x a month. • The filters can be cleaned in a dishwasher. It is however possible that they will become slightly discoloured. • The filter must be placed loosely, and NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. • When cleaning the filters by hand, soak them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and inserting the metal grease filters: IMPORTANT: The lighting must be switched OFF and cool. 1 Press the catch on the grease filters inwards and fold the filters down. At the same time take hold of the underside of the grease filters with your other hand. 2 Clean the filters. 3 Insert the clean filters back into the hood. 4 Cancel the F in the display. – Press the button F. Activated carbon filter For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. Installation and removal: IMPORTANT: The lighting must be switched OFF and cool.. 1 Remove the metal-mesh filters (see "Removing and inserting the metal-mesh grease filters"). 2 Insert the activated carbon filter. 3 Insert the metal grease filters (see "Removing and inserting the metal grease filters"). Replacing the activated carbon filter: • During normal operation (1 to 2 hours per day) the activated carbon filters should be replaced approximately 1 x year. • A replacement filter can be obtained from any authorized dealer (see optional accessories). • Use original filters only. By doing so you will obtain maximum performance from your extractor hood. Disposing of the old activated carbon filter: • There are no pollutants in the activated carbon filters. They can therefore be disposed of as part of your normal domestic refuse. Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! • Clean the extractor hood with a hot soap solution or a mild window cleaner. Wichtig: Es darf keine Flussigkeit in den Schlitz fur den Luftaustritt eindringen. • Do not scrape off dried-on dirt but wipe off with a damp cloth. • When cleaning the grease filters, remove grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. Clean the operating buttons with a mild soapy solution and a soft, damp cloth only. Do not use stainless-steel cleaner to clean the operating buttons. Stainless steel surfaces: • Use a mild non-abrasive stainless steel cleaner. • Clean the surface in the same direction as it has been ground and polished. • We recommend our stainless steel cleaner no. 461731. See enclosed service booklet for order address. Aluminium, coated and plastic surfaces: • Do not use dry cloths. • Use a mild window cleaning agent. • Do not use aggressive, acidic or caustic cleaners. Observe the warranty regulations in the enclosed service booklet. 13 1 Switch the extractor hood off and isolate it by removing the mains plug or by switching off the fuse. When operating, the fluorescent light bulbs get very hot. Even after a while, there is still a risk of being burnt. 2 Remove the metal-mesh filters (see "Removing and inserting the metal-mesh grease filters"). 3 Loosen the screws for the mounting rails.. 4 Carefully remove the glass panes. 5 Remove the sockets for the fluorescent light bulbs. 6 Replace the fluorescent light bulbs with new ones available commercially (36 W, 840 Cool White, socket 2 G 11). Risk of breakage! Replacing the light bulbs 14 7 Insert the sockets for the fluorescent light bulbs. 8 Carefully mount the glass panes. 9 Tighten the screws for the mounting rails. 10 Insert the metal grease filters (see "Removing and inserting the metal grease filters"). 11 Restore the power by inserting the mains plug or switching on the fuse. Note: If the light does not function, check that the bulbs have been inserted correctly. $ $ Important information Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, render it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please as...

Эта инструкция также подходит к моделям:
Вытяжки - AI281120/01 (911.9 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории