Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Lifebreath, модель 95MAX

Производитель: Lifebreath
Размер: 978.2 kb
Название файла: fbb9ed16-008b-44f2-a48f-6e3d82b74de0.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


99-105 Programmable Ventilation Control (PVC) includes Programmable Time Clock, Dehumidistat and Air Sentry™ 99-109 Air Sentry™ Air Quality Monitor designed to accept remotely mounted Control Pad 99-250 Ventilation Dehumidistat -Dehumidistat designed to accept remotely mounted Control Pad. 99-160 Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 7” (178 mm) 99-161 Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 7” (178 mm) 99-186 Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6mm) mesh screen WARRANTY Units carry a LIFETIME warranty on the heat recovery core and a 5 year replacement parts warranty. *NOTE: Front clearance of 25 inches (635 mm) is recommended for servicing unit. 195DCS FANCURVE 225 175 200 100 75 125 150 50 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Air Flow (cfm) HIGH SPEED* MEDIUM HIGH SPEED MEDIUM SPEED MEDIUM LOW SPEED LOW SPEED 4 5 3 2 14 3 2 1 5 *Manufacturers Data Static Pressure (inH20) All units conform to CSA and UL standards. 14 3/4" 19"(483) (375) 511 McCormick Blvd. 270 Regency Ridge, Suite 210 London, Ontario N5W 4C8 Dayton, Ohio 45459 T (519) 457-1904 T (937) 439-6676 F (519) 457-1676 F (937) 439-6685 Email: nutech@lifebreath.com ..Website: TI-101-NE 9 1203 Model 300DCS ENGINEERING DATA THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the twoairstreams. The two cores are arranged for highly efficient counter current airflow. MOTORS AND BLOWERS -Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. 120 VAC, 2.9 Amps. FILTERS - Washable air filters in exhaust and supply air streams. MOUNTING THE HRV - Four threaded inserts at corners of case designed to accept four reinforced polyester straps that are supplied with the unit. DEFROST - Damper defrost system. DEHUMIDISTAT - Adjustable Internal Dehumidistat. CASE - Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections 2 -1/2" (12 mm) OD. CONTROLS - ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode, Recirculation mode, (each mode has 5 speeds). Control pad can be removed from HRV and remotely mounted. WEIGHT 106 lbs. (48 kg) SHIPPING WEIGHT 108 lbs. (49 kg ) DIMENSIONS 300DCS inches (mm) METAL CLASPS FILTER MOTOR PERFORMANCE HVI CERTIFIED Net supply airflow in cfm (L/s) against external static pressure E.S.P cfm L/s @ 0.1” (25 Pa) 265 (125) @ 0.2” (50 Pa) 260 (123) @ 0.3” (75 Pa) 250 (118) @ 0.4” (100 Pa) 235 (111) @ 0.5” (125 Pa) 220 (104) Maximum Temperature Recovery 90% Sensible Effectiveness @ 117 cfm (55 L/s) (CSA C439M) 90% Sensible Efficiency @ 117 cfm (55 L/s) 32°F (0OC) 79% Sensible Efficiency @ 117 cfm (55 L/s) -13°F (-25OC) 75% VAC @ 60HZ 120 WATTS / Low speed 150 WATTS / High speed 333 Amp rating 2.9 49 " (1245) STALE AIR TO OUTSIDE FRESH AIR TO INSIDE Ports 7" (178 mm) CONDENSATE BLOWERS FRESH AIR FROM OUTSIDE STALE AIR FROM INSIDE FILTER DEFROST DAMPER Ports 6" (150 mm) 14 3/4" 19"(483) *NOTE: Front clearance of 25 inches (635 mm) is recommended for servicing unit. DEFROST AIR DRAINS FROM INSIDE OPTIONS 99-104 Digital Electronic Timer - 20/40/60 min. 99-105 Programmable Ventilation Control (PVC) includes Programmable Time Clock, Dehumidistat and Air Sentry™ 99-109 Air Sentry™ Air Quality Monitor designed to accept remotely mounted Control Pad. 99-250 Ventilation Dehumidistat -Dehumidistat designed to accept remotely mounted Control Pad. 99-160 Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 7” (178 mm) 99-161 Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 7” (178 mm) (375) 300DCS FANCURVE 300 275 250 225 200 175 150 125 100 75 Air Flow (cfm) HIGH SPEED* MEDIUM HIGH SPEED MEDIUM SPEED MEDIUM LOW SPEED LOW SPEED 4 5 3 2 1 4 3 2 1 5 *Manufacturers Data 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 99-186 Weatherhoods, Two - 6” (150mm) c/w 1/4” (6mm) Static Pressure (inH20) mesh screen WARRANTY Units carry a LIFETIME warranty on the heat recov- All units conform to ery core and a 5 year replacement parts warranty. CSA and UL standards. 511 McCormick Blvd. 270 Regency Ridge, Suite 210 London, Ontario N5W 4C8 Dayton, Ohio 45459 T (519) 457-1904 T (937) 439-6676 F (519) 457-1676 F (937) 439-6685 Email: nutech@lifebreath.com ..Website: TI-102-NE 10 1203 Model 200ERV ENGINEERING DATA LATENT RECOVERY/MOISTURE TRANSFER CORE The cross-flow energy recovery core transfers heat and water vapour between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. High speed - 120 VAC. FILTERS Washable air filters in exhaust and supply air streams. MOUNTING THE ERV Four threaded inserts at corners of case designed to accept four PVC reinforced polyester straps that are supplied with the unit. CASE Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensatio...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории