|
Фрагмент инструкции
. . . . . . . . . . .2 System Overview . . . . . . . . . . . . .3–5 Installation Instructions . . . .6–12 Battery Installation . . . . . . . . . . . . . . . .11 Faucet Installation . . . . . . . . . . . . . . . .7, 8 Feed Water Supply . . . . . . . . . . . . . . .6, 7 Filter Replacement . . . . . . . . . . . . . . . . .12 Flush Procedure . . . . . . . . . . . . . . . . . . .12 Installing the Tubing . . . . . . . . . . . . . . .11 System Installation . . . . . . . . . . . . . .9, 10 Troubleshooting Tips . . . . . . . . . .13 Consumer Support Consumer Support . . . . . . . .Back Cover Parts List/Catalog . . . . . . . . . . . . . . . . . .14 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .15 Owner’s Manual and Installation Instructions GNSV70RBL GNSV75RWW GNSV70RBL and GNSV75RWW are Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine: Taste and Odor and Particulate Class I and Standard 53 for the reduction of Lead, Cyst, Turbidity, Asbestos, Mercury, Lindane, Atrazine, Benzene and VOC. 215C1219P001 49-50234-3 02-09 JR IMPORTANT SAFETY INFORMATION. WARNING: Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage. ¦ Check with your local public works department for plumbing codes. You must follow their guidelines as you install the Water Filtration system. SAFETY PRECAUTIONS ¦ Use the Water Filtration system on a potable, safe-to-drink, home COLD water supply only. The filter canisters will not purify the water, or make it safe to drink. ¦ Do not use on a hot water supply (100°F max.). Install on a cold water line only. WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. PROPER INSTALLATION This Water Filtration system must be properly installed and located in accordance with the Installation Instructions before it is used. CAUTION: To reduce the risk of property damage due to water leakage, install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather. Water freezing in the system may damage it and may result in water leakage, damaging property. Change the filter out if it was exposed to freezing temperatures. Do not attempt to treat water over 100°F. WARNING: Discard all unused and packaging material after installation. Small parts remaining after installation could be a choke hazard. ¦ Your Water Filtration system will withstand up to 120 pounds per square inch (psi) water pressure. If your house water supply pressure is higher than 80 psi, install a pressure reducing valve before installing the Water Filtration system. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS Specifications Guidelines. The Water Filtration System Uses the Following Canisters Models GNSV70RBL and GNSV75RWW FQSVF Filter (160 gallon capacity) Filter—White canisters with green band • Reduces dirt, rust and sediment • Reduces Chlorine: Taste and Odor • Reduces Lead • Reduces filterable Cysts (such as cryptosporidium and giardia) • Reduces Turbidity • Reduces Asbestos • Reduces Mercury • Reduces Lindane • Reduces Atrazine • Reduces Benzene • Reduces VOC • 0.5–1 micron nominal particulate reduction This system conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and sustained by test data. See Performance Data Sheet for details. Installation Overview Locate the drinking water system on the cold water supply pipe, under the kitchen and/or bathroom sink, to filter the cold drinking water. Sink Water Supply Valve Filtered Water Faucet Inlet Outlet Filter Canisters Manifold Hot Cold Performance Data Sheet. SmartWater Filtration System GNSV70RBL and GNSV75RWW Using Filter FQSVF ¦ This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. ¦ Actual performance may vary with local water conditions. WARNING: Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. Standard No. 42: Aesthetic Effects Parameter USEPA MCL Influent Challenge Concentration Influent Average Effluent % Reduction Maximum Permissible Product Water ConcentrationAverage Maximum Average Minimum Chlorine — 2.0 mg/L + 10% 2.00 mg/L <0.05 mg/L <0.05 mg/L 97.50% 97.50% >50% T & O — — — — — — — — Particulate** — . 10000 particles 4100000 #/mL 76500 #/mL 110000 #/mL 98.10% 97.30% >85% Standard No. 53: Health Effects Turbidity 0.5 ...
Эта инструкция также подходит к моделям:Водоочистители - GNSV75RWW (822.05 kb)