|
Фрагмент инструкции
To lower water temperature use point-of-use temperature limiting devices. WARNING: Flammable vapors may be drawn to this water heater from other areas of the structure by air currents. Do not store or use any flammable liquids in the vicinity of this heater. WARNING: Water heater blankets may restrict air flow to the heater and cause fire, asphyxiation, personal injury or death. Bock Water Heaters, Inc. 110 South Dickinson Street • P.O. Box 8632 • Madison, WI 53708-8632 Phone: 608/257-2225 • Fax: 608/257-5304 • THIS MANUAL HAS BEEN PREPARED TO ACQUAINT YOU WITH THE INSTAL – 2 – LATION, OPERATION, AND MAINTENANCE OF YOUR WATER HEATER AND TO PROVIDE IMPORTANT SAFETY INFORMATION. Read all instructions thoroughly before attempting installation or operation of the water heater. Keep these and all component instructions for future reference. The manufacturer of this water heater will not be liable for any damages caused by failure to comply with the installation and operating instructions outlined on the following pages. These instructions are a guide for the correct installation of the water heater. If the installer lacks the necessary skills or has difficulty following the directions, do not proceed but get help from a qualified person for that part of the installation that is not understood. Local plumbing and electrical codes must be followed in the installation of this water heater. In the absence of a local code use the UNIFORM PLUMBING CODE and the NFPA Code. Local codes may supersede instructions in this instal- lation manual. When two or more burners are used, each unit should have a separate supply line to the fuel pump to prevent nuisance lockouts caused by one or both pumps starving for oil. If this is not possible, the use of a priority control is recommended. Check new equipment to see if all components are in good condition. The water heater and oil burner may be shipped as separate units. The aquastat and immersion well may be packed with the oil burner. The new water heater requires fuel (#I or #2 heating oil), electricity and should be close to the chimney and water supply. Locate the heater near a floor drain if pos- sible for easy maintenance and protection if trouble should occur. Allow ample space around the heater for servicing (see combustible clearance warning, page 1). Adequate air for combustion must be available. NOTE: Locate the heater so it is not subject to physical damage by moving vehicles or possible flooding. CONSUMER RESPONSIBILITIES MULTIPLE BURNER INSTALLATION SELECT THE RIGHT LOCATION FIGURE 1 Check for exhaust fans in the heater room or adja- cent areas which draw combustion air away from heater. THE HEATER MUST HAVE COMBUS- TION AIR TO OPERATE. WHEN THE WATER HEATER IS USED IN A COM- BINED APPLIANCE APPLICATION, PLEASE CONTACT THE LOCAL DISTRIBUTOR OR THE FAC- TORY FOR INSTALLATION INSTRUCTIONS ON “SYSTEM PLUS”. DO NOT INSTALL THE WATER HEATER ON COMBUS- TIBLE FLOORING (see Figure 2). Re...
Эта инструкция также подходит к моделям:Водонагреватели - 33E (180.73 kb)
Водонагреватели - 40E (180.73 kb)
Водонагреватели - 40PP (180.73 kb)
Водонагреватели - 50ES (180.73 kb)