Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Crown, модель 24-10

Производитель: Crown
Размер: 6.19 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


No building heating load. B. Boiler Circulator and Diverting Valve Selection Charts B1. S24, 20 and 40 AT - Taco B2. S24, 20 and 40 AT - Grundfos B3. S24, 20 and 40 AT - Bell and Gossett B4. S24, 20 and 40 AT - Armstrong C. Valve and Actuator Mounting Instructions 7 Section I - General Information SENSINGjg-16 PLUGGED C TOP OUTLET ] BOILER MODEL NUMBER OF SECTIONS 'A' •B' NUMBER OF STEAM RISERS 'C' D' MAXIMUM NUMBER OF HEATERS E' FLUE OUTLET DIAMETER Ti BURNER MOUNTING PLATE WIDTH 'G' BECKETT 1 APPROX. K.D.BLR. SHIPPING WEIGHT LB. CFOIL 'IT CG GAS TT 24-03 3 ie| 12 1 — 1 7 8 93 2Cg 1278 24-04 4 24| 18 1 — 12¿ 1 7 8 ll| 2 lg 1590 24-05 5 cu o 24 1 — 15 ¿ 1 8 8 H| 21g 1902 24-06 6 36 i 30 1 — 18 ¿ 2 8 4 20 g 21g 2218 24-07 7 CM 36 2 — 21 ¿ 2 8 4 20 § 28g 2534 24-08 8 48 i 42 2 — 24¿ 2 10 4 20 § 28g 2846 24-09 9 54¿ 48 2 — 27 i 3 10 4 21 à 2S¿ 3227 24-10 10 60 i 54 2 — 30 i 3 10 4 21 â 2S¿ 3559 24-11 11 66 i 60 2 — 33 ¿ 3 12 4 22 ¡ 2S¿ 3870 24-12 12 72 i 66 3 30 36 ¿ 4 12 4 22 ¡ 2sè 4197 1 BURNER CONTROL PANEL CONFIGURATION MAY CHANGE THIS DIMENSION. 2 DOES NOT INCLUDE BURNER MOUNTING PLATE [SHIPPED SEPARATELY) ADD 55 LB. FOR 4" STANDARD BURNER MOUNTING PLATE ADD 85 LB. FOR 8° EXTENDED BURNER MOUNTING PLATE • NOT SUPPLIED AS STANDARD EQUIPMENT LEFT SIDE VIEW C STEAM 3 FRONT VIEW C STEAM) FIGURE 1: Dimensional Information TABLE I BOILER RATINGS/DATA (1) (2) (3) (4) Boiler Model Horse- Power Gross Output (MBH) Net I=B=R Rating Burner Input Heating Surface (Sq. Ft.) Sq. Ft. Steam MBH Steam MBH Water Oil (GPH) Gas (MBH) Steam Water Net Firebox Volume (Cu.Ft.) Pressure in Firebox ("W.C.) Water Boiler Weight Content w/ Water Vent (Gal.) (Lbs.) Dia. (In.) Steam Water Steam Water 24-03 10.2 342 1071 257 297 3.05 438 34.2 37.0 3.2 .33 44.5 66.0 1439 1618 7 24-04 14.1 471 1471 353 410 4.10 594 48.6 54.3 4.8 .38 53.0 75.0 1811 1995 7 24-05 18.9 634 1983 476 551 5.50 792 63.0 71.5 6.4 .31 61.5 84.0 2184 2372 8 24-06 23.8 797 2492 598 693 6.90 990 77.5 88.8 7.9 .38 70.0 93.0 2557 2749 8 24-07 28.0 937 2929 703 815 8.10 1174 91.9 106.0 9.5 .36 78.5 102.0 2930 3126 8 24-08 32.5 1087 3396 815 945 9.40 1358 106.3 123.3 11.0 .35 87.0 111.0 3303 3503 10 24-09 39.3 1316 4146 995 1148 11.40 1641 120.7 140.5 12.6 .35 95.5 120.0 3676 3880 10 24-10 45.0 1505 4788 1149 1309 13.00 1867 135.1 157.8 14.2 .40 104.0 129.0 4048 4257 10 24-11 50.5 1690 5429 1303 1470 14.60 2093 149.5 175.0 15.7 .45 112.5 138.0 4421 4634 12 24-12 55.3 1852 5983 1436 1610 16.00 2320 164.0 192.3 17.3 .49 121.0 147.0 4794 5011 12 (1) Trim Suffix: S = Steam Boiler, W = Water Boiler Fuel Suffix: N = Natural Gas, P = LP Gas, O = Oil (2) I=B =R net ratings shown are based on piping and pick-up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water. Consult manufacturer for installations having unusual piping and pick-up requirements, such as intermittent system operation, extensive piping systems, etc. The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon. (3) Firebox volume does not include added volume of 8” extended burner mounting plate (BMP). If 8” BMP is specified (refer to Figure 1), add 0.7 cu. ft. to volume listed above. (4) Boiler ratings are based on 12.5% CO2 (oil) and 9.7% CO2 (natural gas), + .10” (inches) water column pressure at boiler flue outlet. Ratings shown above apply at altitudes up to 1000 feet on oil and 2000 feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Maximum Allowable Working Pressure: Steam Boiler - 15 PSI, Water Boiler - 50 PSI Standard Safety (Relief) Valve Set Pressure: Steam Boiler - 15 PSI, Water Boiler - 30 PSI 9 SECTION I - GENERAL INFORMATION (CONTINUED) A. INSPECT SHIPMENT carefully for any signs of damage. 1. ALL EQUIPMENT is carefully manufactured, inspected and packed. Our responsibility ceases upon delivery of crated boiler to the carrier in good condition. 2. ANY CLAIMS for damage or shortage in shipment must be filed immediately against the carrier by the consignee. No claims for variances from, or shortage in orders, will be allowed by the manufacturer unless presented within sixty (60) days after the receipt of goods. 3. Make sure that appropriate items on the Master Parts List (pg 59) are all on hand. B. LOCATE THE UNIT 1. RECOMMENDED SERVICE CLEARANCE - Locate the unit in the boiler room so as to provide ease of venting and adequate clearance for maintenance, serviceability, and installation of piping. Refer to Figure 1 for boiler dimensional data. FRONT — Provide 43” service clearance for removal, maintenance, and servicing of burner and controls. REAR — Provide a minimum clearance from the boiler jacket for access to flame observation port, rear flue damper and vent piping, relief valve, and boiler return piping. See Table III. LEFT SIDE — Provide a minimum clearance ...

Эта инструкция также подходит к моделям:
Водонагреватели - 24-03 (6.19 mb)
Водонагреватели - 24-11 (6.19 mb)
Водонагреватели - 24-12 (6.19 mb)
Водонагреватели - 24-04 (6.19 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории