Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Chamberlain, модель 935CB

Производитель: Chamberlain
Размер: 164.86 kb
Название файла: 114A2398.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This door control contains a motion detector that will automatically turn on the light when it detects a person entering the garage. This feature can be easily turned off for extended work light use. Locate the door control within sight of the door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of the door and door hardware. NOTE: After installation, an indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct). INSTALLATION The door control is typically attached directly to the wall. For pre-wired installations (as in new home construction), it can be mounted to a standard single gang box. See illustrations. If installing the door control adjacent to existing door controls, be sure the detector switch is accessible. 1. Disconnect power to the garage door opener. 2. Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to 2 and white/red wire to the 1. 3. Remove white cover by gently prying at slot in top of the cover with a small flat head screwdriver. Fasten with 6ABx1-1/4" self-tapping screws (drywall installation) or 6-32x1" machine screws (into gang box) as follows: • Drill and install bottom screw, allowing 1/8" (3 mm) to protrude above wall surface. • Position bottom of door control on screw head and slide down to secure. Adjust screw for snug fit. • Install top screw with care to avoid cracking plastic housing. Do not overtighten. • Insert top tabs and snap on cover. OPENER TERMINAL SCREWS Opener Panel Antenna 1 2 3 Push Bar Light Button Lock Button LOCK LIGHT Motion Detecting Control Panel ® NOTE: The push bar may stick if the door control is not mounted on a smooth surface. If a click is not heard when pressing the push bar, loosen the two mounting screws or relocate the door control to a smoother surface. 4. (Standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit. 5. Strip 7/16" (11 mm) of insulation from end of bell wire. For quick-connect terminals, connect bell wire as follows: white to white and white/red to red. For opener terminal screws, connect white to 2 and white/red to 1. NOTE: When connecting multiple door controls to the opener, twist same color wires together. Insert wires into quick-connect holes: white to white and red/white to red, or for terminal screws: attach white to 2 and white/red to 1. The automatic light feature will become functional 1-1/2 minutes after power is restored. To prevent possible SERIOUS INJURY or DEATH from electrocution: • Be sure power is not connected BEFORE installing door control. • Connect ONLY to 24 VOLT low voltage wires. To prevent possible SERIOUS INJURY or DEATH from a closing garage door: • Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from all moving parts of door. • NEVER permit children to operate or play with door control push buttons or remote control transmitters. • Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel. • ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door. WARNING CAUTION WARNING WARNING To release wire, push in tab with screwdriver tip QUICK-CONNECT TERMINALS Red White Grey 7/16" (11 mm) Strip wire 7/16" (11 mm) 1 RED 2 WHITE Door Control Terminal Screws 24 Volt Bell Wire Back View Bottom Mounting Hole Top Mounting Hole LOCK LIGHT To Replace Insert Top Tabs First Detector Switch Push Bar Cover ON OFF STANDARD WALL MOUNT 24 Volt 2-Conductor Bell Wire PRE-WIRED INSTALLATION LOCK LIGHT To Replace Insert Top Tabs First Detector Push Bar Cover Switch ON OFF STANDARD WALL MOUNT SPTRAEN-WDAIRREDD W INASLTLA MLLOAUTNIOTN OPERATIO N Door Control Push Bar: Press to open or close the door. Press again to reverse the door during the closing cycle, or to stop the door while it is opening. Light Feature: Press the Light button to turn the opener light on or off. When the door is opened or closed, the light will remain on for 4-1/2 minutes. Press the Light button to turn it off sooner. The Light button will not control the opener light when the door is in motion. When using the opener lights as working lights, we recommend that you first disable the motion sensor. See Automatic Light Override Feature, below. When used with openers manufactured after May 15, 1999, (check the date on the opener panel) the 4-1/2 minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold the Lock button until the light blinks (about 10 seconds). A single blink indicates that the timer is reset to 1-1/2 minutes. Repeat the procedure and the light wi...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории