Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Sony, модель SLV-GA59SG

Производитель: Sony
Размер: 143.09 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


sharpness (Auto Sharpness new ones if they are weak. does not have a TV tuner. Others Initial settings are indicated in bold print. Although the unit automatically adjusts the highlight USER SET and press OK. tracking when playing a tape, distortion may Control) The tracking meter does not • The recording condition of the tape is very poor and appear on the TV screen. tracking cannot be adjusted. USER SET occur if the recording is in poor condition. You can automatically adjust the sharpness In this case, manually adjust the tracking. of the picture. Menu option Set this option to To stop editing The unit needs to be • Clean the cabinet, panel, and controls with a dry soft cleaned. cloth, or a soft cloth slightly moistened with a mild OSD • ON to display the menu on detergent solution. Do not use any type of solvent, such During playback, press TRACKING +/– to Press the x STOP buttons on both units. the TV screen. display the tracking meter. The distortion 1 During playback, press MENU, then as alcohol or benzine. • OFF to disappear the menu To check the remaining tape length should disappear as you press one of the two press v/V/b/B to highlight USER from the TV screen. z REC buttons. To resume automatic tracking SET and press OK. Press DISPLAY. The white bar indicates the X PAUSE Auto head cleaner adjustments, eject the tape and re-insert it. approximate length of the tape recording. TAPE • E180 to use an E-180 or 2 Press v/V to highlight ASC, then press SELECT shorter type tape. The unit incorporates an auto head cleaner which cleans the video heads when a tape is loaded Before you start editing 2 Press v/V to select the option. • E240 to use an E-240 type B. or unloaded. When the heads are not sufficiently clean, even after a tape has been loaded/ tape. • Turn on your TV and set it to the video unloaded several times, use a video head cleaning cassette. channel. 3 Press B to change the setting, then press • E260 to use an E-260 type tape. Symptoms caused by contaminated video heads OK. • E300 to use an E-300 type tape. 1 Press REC SPEED to select the tape • Normal picture • Rough picture • Unclear picture • No picture (or black speed (SP or LP for the PAL color & white screen system, and SP or EP for the NTSC COLOUR • AUTO to select the colour appears) SYSTEM system automatically. Remaining tape length • PAL to use the tape color system). LP provides a recording time twice as recorded in the PAL colour long as SP. EP provides a recording time To turn the display off, press DISPLAY system. 3 Press v/V to set ASC to ON or OFF. three times as long as SP. again. • MESECAM to use the tape • ON: Picture sharpness is recorded in the MESECAM However, SP produces better picture To save a recording colour system. automatically adjusted. quality. terminalinitial contamination • B/W to use the tape To prevent accidental erasure, break off the • OFF: Adjust the picture sharpness recorded in black and white. 2 Insert a source tape with its safety tab safety tab as illustrated. To record on a tape again, cover the tab hole with adhesive tape. When using the tape recorded manually. removed into the other (playback) VCR. To soften the picture, press b. NTSC colour signals: Search for the point to start playback To sharpen the picture, press B. Safety tab • NT3.58 to use the tape and set it to playback pause. recorded in the NTSC 3.58 colour system. 3 Insert a tape with its safety tab in place • NT4.43 to use the tape into this (recording) unit. Search for the recorded in the NTSC 4.43 colour system. point to start recording and press X PAUSE. • NTPB to play back an NTSC-recorded tape on Tips PAL TV. • To edit more precisely, press the X PAUSE buttons on the units to release pause. ASC • ON to automatically adjust 4 Press MENU to return to the original the sharpness of the picture. • To cut out unwanted scenes while editing, screen. press X PAUSE on this unit when an unwanted • OFF to manually adjust the scene begins. When that scene ends, press sharpness of the picture. X PAUSE again to resume recording. Additional information TV system Editing with another unit SpecificationsSetting the recording duration time Troubleshooting If you have any questions or problems not covered below, please consult your nearest Sony System General After you have started recording in the To extend the duration Connections necessary to Tip service facility. Color system Power requirements record on this unit • Use Sony’s commercially available connecting normal way, you can have the unit stop Press z REC repeatedly to set a new PAL, MESECAM, NTSC 3.58, NTSC 4.43 110 – 240 V AC, 50/60 Hz cable. If the other VCR has the AUDIO L and recording automatically after a specified Symptom Remedy duration time. G, K, I Power consumption R jacks, use a Sony connecting cable (3-phono duration. Tape speed 10 W The ?/1 ON/STANDBY switch • Connect the mains lead to the mains securely. to 2-phono). To view the duration time Tracking meter SP: PAL 23.39 mm/...

Эта инструкция также подходит к моделям:
Видеомагнитофоны/видеоплееры - SLV-GA59ME (143.11 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории