The connection to the mains is carried out as follows: BROWN = L line BLUE = N neutral If not provided, connect a plug for the electrical load indicated on the description label. Where a plug is provided, the cooker hood must be installed in order that the plug is easily accessible. An omnipolar switch with a minimum aperture of 3mm between contacts, in line with the electrical load and local standards, must be placed between the appliance and the network in the case of direct connection to the electrical network. • The appliance must be installed at a minimum height of 650 mm from an cooker stove in case of a gashob or an electrical hob. If a connection tube composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the cooker hood exhaust to the same conductor used to circulate hot air or for evacuating fumes from other appliances generated by other than an electrical source. •MOUNTING OF THE HOOD IN THE LOWER PART OF AN HANGING CUPBOARD Drill 4 holes of 6 mm. diameter at the bottom of the hanging cupboard as showed in the drawing fig.3. Fit the hood in the cabinet with 4 screws, which are appropriate to that kind of cupboard. The appliance is provided with 2 air outlets, one which is in the upper part and the other on the back. Both of them can be used according to your requirements. A connecting ring (C), which to join the connecting pipe to,and a cover (A) to close the air outlet, which is not used, are supplied. • MOUNTING OF THE HOOD IN THE WALL Make 4 holes (B-P) according to the measurements indicated in fig. 2. For the various assembly operations, use screws and anchors suitable for the type of wall (eg., concrete, plasterboard, etc.) Hang the hood on the wall using the two holes (B) fig. 2. Secure the hood to the wall using the two lower safety holes (P). • MOUNTING OF THE HOOD ON THE WALL Drill 2 holes on the wall, which correspond to the position (B) of the drawing fig. 1. Hang the hood on the 2 holes by using the screws and dowels with expanding plug ,which are aprropriate for that kind of wall (ex. concrete, plasterboard etc.) Fix definitely the hood through the 2 security holes (Z). • FITTING THE PIPES (OPTIONAL) Make four holes (G-H) according to the measurements indicated in fig. 2 For the various assembly operations, use screws and anchors suitable for the type of wall (eg., concrete, plasterboard, etc.) Secure the bracket (Z) to the wall fig. 2 Position the two pipes vertically on the hood. Hang the pipe fitting (F) using the 2 holes (H) fig. 2 Remove pipe fitting (E) from fitting (F) and secure to the side of the bracket (Z) with the screws provided. • FITTING THE GLASS SECTION (OPTIONAL) Position the glass section complete with supports (V) as indicated in fig. 1 and secure to the hood using the screws provided. - 7 • FITTING THE HANDLE (OPTIONAL) Position the handle (M) and the two right (D) and left (S) supports, as indicated in fig. 1, and secure to the hood using the screws provided. •CHANGING FROM EXHAUSTING HOOD TO FILTERING ONE In order to make this change (possible also after the use of the exhausting system), demand a set of carbon filters to your dealer. Active carbon filters are necessary to depurate the air, that will be released in the room. Filters are not washable; they cannot be regenerated and have to be replaced at most every 4 months. The saturation of the activated charcoal depends on the more or less prolonged use of the hood, on the type of cooking and on the regularity of cleaning the grease filter. The filter (C) has to be applied to the aspirating group, which is inside the hood hiting the centre of the group with it and turning it of 90 degrees until the stop click is heard to lock it. Remove the grill (G) to carry out this operation. Close with the appropriate covers the upper and back air outlets; turn the small lever (L) from the position (A) to the position (F). In this way the hood is ready for the filtering function. USE AND MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours. The proper function of the cooker hood is conditioned by the regularity of the maintenance operations, in particular, the active carbon filter. • The anti-grease filters capture the grease particles suspended in the air, and are therefore subject to clogging according to the frequency of the use of the appliance. In order to prevent fire hazard, it is recommendable to clean the filter at a maximum of 2 months by carrying out the following instructions: -Remove the filters from the cooker hood and wash them in a solution of water and neutral liquid detergent, leaving to soak. - Rinse thoroughly with warm water and leave to dry. -The filters may also be washed in the dishwasher. The aluminium panels may alter in colour after se...

Эта инструкция также подходит к моделям:
Вентиляторы - COOKER HOOD PN-36 (382.43 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории