Войти:
Оценок - 0, средний балл: 4 ( )

Инструкция по эксплуатации Smeg, модель Hood KSE951X

Производитель: Smeg
Размер: 466.46 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


RECIRCULATION VERSION AIR OUTLET • Push fit connection 15 onto the hood body outlet. . • Insert the connection extension pieces laterally 14.1 in connection 15. • Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the connection extension pieces 14.1 and then reassemble as described previously. • Ensure that the activated charcoal filters have been inserted. DUCTED VERSION AIR EXHAUST SYSTEM EN 30 ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. . Chimney assembly Upper exhaust Chimney • Slightly widen the two sides of the upper chimney and hook them behind the brackets 7.2.1, making sure that they are well seated. • Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied. Lower exhaust Chimney • Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall, making sure that they are well seated. • Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied. EN 31 USE Control board Key Function Display A Switches the motorselected speed on and off at the latest Indicates the selected speed B Decreases the suction speed. - C Increases the suction speed. - D By pressing this key it is possible to start the intensive speed from any previously selected speed. This speed has been timed at 10 minutes. After that time the system activates automatically the latest selected speed. This function is recommended for cooking condition where vapours and odours need to be eliminated immediately and quickly. HI and the remaining time appear alternately. The spot down at the right side flashes once a second. By pressing the key the function is stopped. E By pressing this key it is possible to set up the motor to a suction speed at 100 m3/h. During the intensive speed or the Delay-function this function cannot be activated. 24 appears and the spot down at the right side flashes while the motor is on. By pressing the key the function is stopped. F By pressing this key it is possible to set the delayed shutdown of the hood to 30 minutes. This function is suitable for a complete elimination of residual cooking odours. Functioning only when the motor is on(not during the 24Hfunction or intensive function) The suction speed and the remaining time before the hood shut down appear alternately The spot down at the right side flashes. By pressing the key the function is stopped G By pressing this key for about 2 seconds it is possible to reset the filter saturation alarm. After 100 working hours a FF appears. Metal grease filters have to be washed. After 200 working hours EF appears. Charcoal filters have to replaced. H By pressing this key the intensity of the lighting system can be decreased cyclically. I Switches on/off themaximum intensity. lighting system at the L By pressing this key the intensity of the lighting system can be increate intensity. Keyboard lock: it is possible to jam the keyboard when, for example, cleaning the glass. The motor and lights are switched off. By pressing the D-key (Intensive function) the keyboard block can be activated or deactivated. This function is confirmed by a Beep and by moving motor LEDS on display. EN 32 EN 33 33 MAINTENANCE Metal grease filters Filters can be washed in the dish machine. They need to be washed when FF-sign appears on the display or in any case every 2 months, or even more frequently in case of particularly intensive use of the hood. Alarm reset • Press the G-key for at least 2 seconds. Cleaning • Remove the filters one at a time holding them up with one hand and pulling the handle downwards with the other hand at the same time. • Wash the filters. Pay attention not to bend them. Make sure that filters are completely dry before putting them into their seat. (a possible modification of the filter surface doesn’t influence its efficiency). • Place the filters again into their seats and make sure that the handle of the filter remains outside. Charcoal filter (recycling version) This filter cannot be washed or regenerated. It has to be replaced when the EF appears on the display or at least once every 4 months. Activation of the alarm signal • In the recycling version hoods the filter saturation alarm has to be activated during the installation or later. • Switch off the hood and the lights. • Press the E-key for about 5 seconds until the LED on the display start to move. • Press the B-key within 5 seconds until a confirmation of the activated state of filter saturation alarm on the display appears: • 2 flashings on EF - charcoal filter saturation alarm ACTIVATED • 1 flashing on EF - charcoal filter saturation ...

Эта инструкция также подходит к моделям:
Вентиляторы - Hood KSE912X (466.46 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории