|
Фрагмент инструкции
2 1 Telescopic Chimney comprising: 2.1 1 Upper section 2.2 1 Lower section 9 1 o150-120 Ducting spigot 10 1 o120-125 Ducting flange 15 1 Air outlet connector Ref Qty Installation Components 7.1 2 Hood body fixing brackets 7.2.1 2 Upper chimney wall fixing brackets 12c 6 Chimney fixing screws 12d 2 Screws M4x25 Ref Qty Documentation 1 Instruction booklet Installing the Cooker Hood Fitting the Wall Brackets • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (H=height of the visible part of the panel) for installation with the back panel. • Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. • Mark the wall at the centres of the holes in the bracket. • Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. • Mark the wall at the centres of the holes in the bracket. • Place bracket 7.1 as shown 95 mm from the vertical reference line and 210 mm above the horizontal reference line. • Mark the centres of the holes in the bracket. • Repeat this operation on the other side. Splashback (Optional) The Splashback must be fitted before fixing the hood body and, if it is to be fixed at both top and bottom, must be fitted at the correct height prior to installing the bases.As this operation is rather complex, it should be carried out either by the kitchen installer or a qualified person who knows the final dimensions of the units. For fixing at the top only, proceed as follows: • Rest the back panel on the base, inserting the lower plate between the upper surface and the wall, centring it on the vertical reference line. • Mark the centres of the two holes in the upper plate. • Drill o 8 mm holes at all the centre points marked. • Insert the wall plugs (not supplied) in the holes. • Fix the brackets using the screws (not supplied). • Fix the back panel (where present) using the screws (not supplied). Note: If the hood is to be installed onto a hollow construction or plaster or partition board wall then special fixing screws will be required (not supplied). Fitting the Canopy Hood • Screw the two screws item 12d supplied onto the brackets 7.1. • Hook the hood body onto the bracket 7.1, centring it around the vertical line. • Use the adjusting screws item 12d underneath the hood to level the hood body Extraction (Ducted) The cooker hood is more effective when installed in the extraction mode (ducted to the outside). Venting kits may be purchased through your retailer or DIY store, and must be evacuated through an outside vent of o125 (5ins) or o150mm (6ins). The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102-B1. When the cooker hood is ducted to the outside the charcoal filter must be removed. Fitting the Ducting • Fit the o150mm (6ins) ducting to the spigot on top of the hood body as illustrated. • When using o125mm (5ins) ducting fit item 9 and 10 on to the spigot on the top of the hood body as illustrated. • For the best performance use the shortest possible run of ducting and we recommend the use of rigid pipe in preference to flexible hose as this will improve the flow of air while reducing turbulence, which causes noise and a loss of performance. • If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler, then its flue must be be of the room sealed or balanced flue type. • If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room. • The cooker ducting when fitted in the extraction mode must never be connected to central heating flues, radiators or water heaters. Recirculation Mode The cooker hood is supplied specified for use in the recirculation mode, with the charcoal filter fitted. In the recirculation mode contaminated air is passed through the charcoal filter to be purified and recirculated into the kitchen through the grille outlets on either side of the chimney. • Push fit the air outlet connector item 15 onto the air outlet. • Ensure the activated charcoal filter has been fitted. Fitting the Upper Chimney • Slightly widen the two sides of the upper chimney and hook them behind the brackets item 7.2.1 ensuring they are correctly seated. • Secure the sides to the brackets using the 4 screws item 12c (2.9 x 9.5mm) supplied. Fitting the Lower Chimney • Slightly widen the two sides of the lower chimney and hook them between the upper chimney and the wall, ensuring they are correctly seated. • Fix the lower chimney to the hood body using 2 screws item 12c (2.9 x 9.5mm) supplied. • Make sure that th...
Эта инструкция также подходит к моделям:Вентиляторы - JLBIHD601 (309.2 kb)