In the event additional information is desired, your dealer will be more than glad to assist you in every possible way. 4 110498-3 Troubleshooting Guide Problem Possible Cause Remedy 1. Check power Failure to start or no air delivery/ No LCD display 1 air delivery with cooler running No electrical power to unit Fuse blown Circuit breaker tripped Motor overheated Belt too tight Blower bearings dry Motor pulley diameter too large Motor locked Fuse blown in unit control box Incorrect wiring between wall thermostat and cooler Poor connection to Fan motor terminals Unit control board or wall thermostat faulty Replace fuse Re-set breaker Determine cause Adjust belt tension Oil blower bearings Adjust pulley to correct diameter Replace motor Replace Fuse 5. Check that wiring is correct and secured to terminals 6. Check connections to terminal 7. Supply power to control box and check DC voltage at wall thermostat • If voltage between Black & Red terminals is close to 3.5VDC and LCD is blank - wall thermostat is faulty • If voltage is much less than 3.5VDC, remove red wire from terminal. If voltage rises to 3.5VDC - thermostat is faulty. If voltage remains low - unit control board is faulty. Inadequate 1. Insufficient air exhaust 1. Open windows or doors to 2. Belt too loose 3. Pads plugged 4. Motor underloaded increase air flow 2. Adjust belt tension or replace if needed 3. Clean pads 4. Adjust pulley Problem Possible Cause Water drain- 1. Float arm not adjusted ing onto roof properly 2. Overflow assembly leaking Remedy 1. Adjust float 2. Tighten nut and overflow pipe Musty or unpleasant odor 1. Stale or stagnate water in cooler 1. Drain pan and clean pads Motor cycles on and off 1. Low voltage 2. Excessive belt tension 3. Blower shaft tight or locked 4. Bearings dry 5. Motor pulley diameter too large causing motor overload 1. Check voltage 2. Adjust belt tension 3. Oil or replace bearings (Unplug unit) 4. Oil bearings 5. Adjust pulley so full load ampere rating of motor is not exceeded Noisy 1. Bearings dry 2. Wheel rubbing blower housing 3. Loose parts 1. Oil bearings 2. Inspect and realign (Unplug unit) 3. Tighten loose parts Inadequate cooling 1. Inadequate exhaust in house 2. Pads not wet •Pads plugged •Dist. tube holes clogged • Pump not working properly 3. Poor connection to Pump terminals on Control Board 1. Open windows or doors to increase air flow 2. Check water distribution system • Clean pads • Clean • Replace or clean pump (Unplug unit) 3. Check connections Excessive humidity in house 1. Insufficient air exhaust 1. Open doors or windows Register your product online at Limited Warranty This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover damages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or different liability in connection with this product. Terms And Conditions Of Warranty Lifetime Limited Coverage on water reservoir against any leakage due to defects in material. From date of purchase, if any original component part provided by Champion Cooler fails due to defect in material or factory workmanship only, we will provide the replacement part as follows: One year on the cabinet components. Five years on the evaporative media. Two years on the original blower motor if furnished by Champion Cooler. Exclusions From The Warranty We are not responsible for any incidental or consequential damage resulting from any malfunction. We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of a...
Эта инструкция также подходит к моделям:Вентиляторы - AD1C51 (1013.76 kb)
Вентиляторы - AD1C71 (1013.76 kb)
Вентиляторы - AS1C51 (1013.76 kb)
Вентиляторы - AS1C5112 (1013.76 kb)