It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet. This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect. Figure 11 The use of the following gas connectors is recommended: — ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings — ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction. The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length. Pressure Testing of the Gas Supply System 1. To check the inlet pressure to the gas valve, a 1/8" (3.175mm) N.P.T. plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance. 2. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). 3. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Attention! If one of the procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter Tubing, Type L Outside Diameter Nat. L.P. Nat. L.P. 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7mm 3/8” 9.5mm 10-40 feet 4-12 meters 1/2” 12.7mm 1/2” 12.7mm 5/8” 15.9mm 1/2” 12.7mm 40-100 feet 13-30 meters 1/2” 12.7mm 1/2” 12.7mm 3/4” 19mm 1/2” 12.7mm 100-150 feet 31-46 meters 3/4” 19mm 1/2” 12.7mm 7/8” 22.2mm 3/4” 19mm PLACEMENT OF GLOWING EMBERS AND LAVA ROCK Placement of the glowing embers (rock wool) is very individual and light coverage will provide your best effects. We recommend separation of the rock wool by hand and make your coverage as light and fluffy as possible. Place just enough embers on the burner to obtain the glow and a gold, yellow flame. Do not place embers (rock wool) over large ports in rear portion of burner. Rock wool should not be placed in the area of the pilot assembly. Replacement of loose material (glowing embers) must be purchased from Empire Comfort Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater. WARNING: All previously applied loose material must be removed prior to reapplication. Refer to Parts List, Page 21 to order loose material (rock wool). Placing Lava Rock in Front of Burner on Fireplace Floor Spread lava rocks on fireplace floor in front of the burner pan. The lava rocks are for decorative effect and are not required for fireplace operation. Attention: Do not place lava rocks on Burner, logs or rock wool. The lava rocks should only be placed on the fireplace floor. OPERATION INSTRUCTIONS/FLAME APPEARANCE Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed. In normal operation at full rate after 10 to 15 minutes, the flame appearance should be sets of yellow flames. Notice: All flames will be random by design, flame height will go up and down. Glowing embers (rock wool) can cover the pan burner in between the front and middle logs, but very little is necessary to cover this area. ...
Эта инструкция также подходит к моделям:Вентиляторы - VFSM-18-3 (1.47 mb)
Вентиляторы - VFSR-16-3 (1.47 mb)
Электрообогреватели - VFSM-18-3 (1.47 mb)
Вентиляторы - VFSV-30-3 (1.47 mb)