Any installation above 750 mm will compromise the extraction performance. The air outlet from the motor requires 150 mm round ducting which requires a 160 mm (min) diameter hole in the ceiling. A = 600 min (electric cook top) A = 650 min (gas cook top) B = 225 mm C = 260 mm Ducting options Recirculation For recirculation, please purchase a recirculation kit (part no. RR1744). The recirculation kit is required to channel the air out through the side-vents at the top of the flue. Note: a ducting hole is not required in the wall or ceiling if a recirculation kit is fitted. Ducting For ducted installation, it is recommended that you use 150 mm diameter, rigid or semi-rigid ducting. This will require a 160 mm (min) round hole in the ceiling, which the decorative chimney will cover. Care should be taken to align the canopy with the decorative chimney allowing sufficient clearance to accommodate the ducting. For optimal efficiency, use smooth-wall, solid galvanized or plastic ducting for reduced noise and increased airflow. Flexible ducting should only be used as a last resort (ie in difficult installations) and if used, ensure that it is pulled tight. The smoother, straighter and shorter the ducting the quieter and more efficient the wall canopy will perform. All ducting must comply with local requirements and building codes. Note: we recommend an Easy Fit by Fisher & Paykel or a UNIDUCT ducting system, products that have been designed to expel air efficiently. Preparing the wall canopy for installation Please read the instructions carefully before installing the wall canopy. Remove the filters from the canopy to allow access to wall mounting holes. To remove the filters, pull the relative catch, tilting it downwards until it disengages from the supports. Reverse these instructions when refitting the filters. Prior to drilling any holes, check that the area behind the surface to be drilled is clear of any electrical cables or pipes etc. Stainless steel/Iridium is very easily damaged during installation if abraded or knocked by tools. Whenever possible, protect the cooktop with cardboard or the like, to prevent damage on installation. Filter surface Cooktop Fig.2 Positioning 4 Installation instructions 1 Before commencement, unpack the wall canopy and check that it functions correctly. 2 Pre-drill pilot hole 3 mm diameter at dimensions C and B: B = 225 mm and C = 260 mm. Note: Fixing to a solid stud is recommended, see Fig.4. 3 Loosely fix the 12 x 2” screws and 2 x cup washers in position, check with a spirit level across the screws to ensure they are level. 4 Mark the position of the decorative chimney at the ceiling and wall. Cut the cornice moulding away if required, to enable the chimney to fit flush against the wall and ceiling. 5 Mark and cut out the hole in the ceiling or wall to fit the ducting (160 mm (min) diameter). This is positioned centrally above the wall canopy, with a centre line 100 mm from the wall (for the ceiling option). 6 Using the screws supplied, fix the chimney bracket to the wall or ceiling, checking that it is centrally located above the canopy. 7 Remove the protective plastic covering from all parts including the filters. 8 Fit the wall canopy onto the mounting screws and tighten. 9 Connect and secure the ducting (use duct tape if required). 10 Assemble the chimney pieces to a height that best suits the installation, leave these screws loose so that the chimney is free to extend by a few mm. Place the two pieces onto the canopy top and secure the lower part to the canopy sides. Extend the upper chimney to the ceiling and secure in place with the screws supplied. Diameter 160 mm (min) centre to wall Note: fix to a solid studC = 260 mm Fig.3 Installation of unit 100 mm from B = 225 mm See “A” on page 3 Fig.4 Bolt into solid stud Getting started quickly Control panel Fan On/Off Mid Speed High Speed Delay Off Switch Light On/Off Fig.5 Control panel DELAY OFF SWITCH: Enables the wall canopy to remain on a low, mid or high speed for five minutes, to clear away all residual cooking odours before switching off automatically. Cleaning and maintenance Caution! Never use abrasive or oil based liquid cleaners. General maintenance The manufacturer is not liable for any damage caused by not following these instructions. The wall canopy should be cleaned regularly using warm water with soap or mild liquid detergents. This ensures that no build-up of grease occurs as these deposits are corrosive. Do not use abrasives or harsh detergents/cleaning fluids. Note: in areas of high humidity and coastal environments cleaning should be carried out frequently. Aluminium filters The grease filters must be periodically cleaned (at least every two months). Remove the grease filters and wash them either by hand using hot soapy water or place them in the dishwasher using mild detergent. Badly smoked filters may be cleaned with “cookware cleaners”. Note: some discolouration of the frame may occur. Charcoal filters ...

Эта инструкция также подходит к моделям:
Вентиляторы - HC90DMB1 (451.19 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории