Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации HoMedics, модель BPS-060

Производитель: HoMedics
Размер: 1.58 mb
Название файла: 73cf0743-b2c7-40e3-aafe-fa0ca49612cf.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


• Before measurement, it is suggested that you sit quietly for 15 minutes as measurements taken during a relaxed state will have greater accuracy. You should not be physically tired or exhausted while taking a measurement. • During the measurement, do not talk or move your arm or hand muscles. • See page 24 for additional notes regarding your blood pressure measurement. If you are using this blood pressure monitor for the first time, please remove the protective film from the screen. 17 18 1. With the cuff wrapped around your arm, press the START/STOP button. Do not inflate the cuff unless it is wrapped around your arm. All digits will light up to check the display functions. The checking procedure will be completed after about 3 seconds. The ( ) arrow will appear momentarily and then the display will show a “00”. The monitor is “Ready to Measure” at this point. 2. Using the hand of the arm that does not have the cuff on it (this will be your right hand if wearing the cuff on your left arm), squeeze the inflation bulb and continue pumping until the pressure reading on the display reaches 140 mmHg. The cuff will then begin slowly deflating as part of the measurement process. If the pressure in the cuff is not enough, an upward arrow ( ) will appear, directing you to continue pumping. It is recommended that you pump until the downward arrow ( ) appears. 19 3. When the measurement is completed, the cuff will deflate entirely. Systolic pressure, diastolic pressure and pulse will be shown simultaneously on the LCD screen. The measurement is then automatically stored into memory. Note: 1. This monitor automatically turns off approximately 1 minute after last operation. You may also press the START/STOP button to turn the unit off. 2. To interrupt the measurement, you may press the START/STOP button (recommended), “MEM”, or Date/Time Set buttons. The cuff will deflate immediately after a button is pressed. 20 RISK CATEGORY INDICATOR The U.S. Department of Health and Human Services and the National Institutes of Health have developed a blood pressure standard classifying blood pressure ranges into 4 stages. This unit is equipped with an innovative blood pressure classification indicator, which visually indicates the assumed risk level (normal, prehypertension, stage 1 hypertension, or stage 2 hypertension) of each reading. Symbols are described below and classifications follow the guidelines as described earlier in this manual (page 5). (No Symbol) RECALLING VALUES FROM MEMORY 1. Press the “MEM” button to access the memory. 2. The monitor will first display the calculated average applied to the last 3 memories. 3. Every new press of the “MEM” button will recall a previous reading. The latest reading will be recalled first. 21 22 CLEARING VALUES FROM MEMORY Press and hold the date & time set buttons() at the same time while in memory mode and the data will be erased automatically. 23 IMPORTANT NOTES REGARDING YOUR BLOOD PRESSURE MEASUREMENT • Take your reading in a comfortable environment as measurements can be affected by hot or cold temperatures. Take your blood pressure at normal body temperature. • Do not move or talk during measurement as this can elevate readings. • Do not move or cross legs during measurement. Keep feet flat on floor. • Do not touch cuff or monitor during measurement procedure. • It is suggested that you take your measurements at the same time each day and use the same arm for consistency. • Users should wait a minimum of 5 minutes before taking additional measurements. More time may be necessary depending upon your physiology. • The measurement results that users receive are for reference only. If users have any blood pressure concerns, please consult a physician. • Once inflation reaches 300 mmHg, the unit will deflate automatically for safety reasons. • This product is not suitable for people with arrhythmias. • This device may have difficulty determining the proper blood pressure for users with diabetes, poor circulation of blood, kidney problems, or for users who have suffered a stroke. 24 RECALIBRATION SERVICE All digital blood pressure monitors require recalibration in order to ensure continued accuracy. This monitor does not require recalibration for 2 years under normal usage conditions (approximately 3 times per day), at which time your monitor will display “ ”. The unit should also be recalibrated if the monitor sustains damage due to blunt force (such as dropping) or exposure to fluids or extreme hot or cold temperature changes. Please fill in date of first use (Recalibration is recommended after 2 years.) To send monitor for recalibration, please ship to the address below with check or money order in the amount of $10 payable to HoMedics, Inc. for recalibration service and shipping & handling: HoMedics Recalibration Service Center P.O. Box 7050 Walled Lake, MI 48390 Allow up to 3 weeks for return of product. For additional information, contact HoMedics Consumer relations at 1-800...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории