Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Hotpoint, модель HE91

Производитель: Hotpoint
Размер: 1.58 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Never use the hood for purposes other than for which it has ben designed. • Never leave high naked flames under the hood when it is in operation. • Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. • Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. • When frying, never leave the pan unattended. • The hood should not be used by children or persons not instructed in its correct use. MAINTENANCE • Switch off and unplug the appliance from the mains supply before carrying out any cleaning or maintenance work. • Clean regularly (see Care and Cleaning section), build up of dirt and grease could cause a fire hazard. GB 3 INSTALLATION Dimensions Hood Type 60 90 L 598 898 Technical Characteristics Basic Hood Supply Voltage 220-240V Supply Frequency 50Hz Insulation Class IInd Weight 12kg Motor Qty Power 6/40K-A 1 150W 6/50K-A 1 190W 8BS/28K-A-P 1 205W GB 4 INSTALLATION Components Ref. 1 Qty 1 Ducted Version Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 7.1 2 Hood Body Fixing Brackets 7.2.1 2 Upper Chimney Section Fixing Brackets 8a 1 Right Air Outlet Grill 8b 1 Left Air Outlet Grill 9 1 Reducer Flange o 150-120 mm 11 8 Wall Plugs 12a 8 Screws 4.2 x 44,4 12d 12e 2 Screws M4 x 25 14 6 1 Screws 2.9 x 9.5 Hood Body Air Outlet Extension Piece consisting of two half shells 15 1 Air Outlet Connection 16 1 Air Outlet Deflector 17 2 Lower Chimney Fixing Bush Qty Documentation 1 Instruction Manual Ref. 1 Qty 1 Recirculation or Ducted Version Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 7.1 2 Hood Body Fixing Brackets 7.2.1 2 Upper Chimney Section Fixing Brackets 8a 1 Right Air Outlet Grill 8b 1 Left Air Outlet Grill 9 1 Reducer Flange o 150-120 mm 11 8 Wall Plugs 12a 8 Screws 4.2 x 44,4 12d 2 Screws M4 x 25 12e 6 Screws 2.9 x 9.5 15 1 Air Outlet Connection 117 2 Lower Chimney Fixing Bush Qty Documentation 1 Instruction Manual GB 5 INSTALLATION Wall drilling and bracket fixing Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (height of the visible part of the panel) for installation with the back panel (see diagram above). • Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line. • Mark the wall at the centres of the holes in the bracket. • Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. • Mark the wall at the centres of the holes in the bracket. • Place bracket 7.2.1 as shown 120mm from the vertical reference line and 175mm above the horizontal reference line. • Mark the centres of the holes in the bracket. • Repeat this operation on the other side. Rear Panel (optional) The rear panel must be fitted before fixing the hood body and if it is to be fixed at both top and bottom, must be fitted at the correct height prior to installing the bases. As this operation is rather complex, it should be carried out either by the kitchen installer or a qualified person who knows the final dimensions of the units. For fixing at the top only, proceed as follows: • Rest the back panel on the base, inserting the lower plate between the upper surface and the wall, centring it on the vertical reference line. • Mark the centres of the two holes in the upper plate. • Drill o 8 mm holes at all the centre points marked. • Insert the wall plugs 11 in the holes. • Fix the brackets using the 12a screws supplied. • Fix the back panel (where present) using the 12a screws supplied. GB 6 Mounting the hood body • Screw the two screws 12d supplied onto the brackets 7.1 • Hook the hood body onto bracket 7.1, centring it around the vertical line. • Using the adjusting screws 12d underneath the hood to level the hood body. Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe o 150 or 120 mm, the choice of which is left to the installer. • To install a o 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. • Fix the pipe in position using sufficient pipe clamps (not supplied). • Remove any activated charcoal filters. Side air exhaust on ducted version (connection to exhaust flue above wall cupboards). • Assemble the half-shells of the hood body extension piece 14. • Push fit the assembled hood body extension 14 onto the air exhaust outlet. • Insert the deflector 16 into the air exhaust fitting 15 to close off...

Эта инструкция также подходит к моделям:
Вентиляторы - HE61 (1.58 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории