All connections should be as airtight as possible to maximize system performance. 1. Connect one end of the ducting (not included) to the room level collar/damper and the other end to the “Y” transition. Secure both ends in place using tape or a screw clamp to create as air tight a seal as possible. Repeat this step for the other room level grill housing (Figure 7). Exhaust to Wall/Roof Cap Fan “Y” Transition Collar/Damper Ducting Figure 7 NOTE: Units that include only one collar do not utilize the “Y” transition. Follow the same instructions as in step 1, except connect the one end of the ducting directly to the fan. 2. Connect one end of the ducting to the top of the “Y” transition and the other end to the intake of the fan (Figure 7). 3. Connect one end of the ducting to the exhaust of the fan and the other end to a wall or ceiling cap (Figure 7). Always duct the fan to the outside through a wall or roof cap. 5S7635036 New 9-06 3 of 12 NOTE: When using insulated flex duct, it is recommended that the inner vinyl core be screw clamped or taped to the inlet and outlet and that the vapor barrier surrounding the insulation be taped to the fan housing. NOTE: When attaching flex duct to the collar/damper combination and an immediate elbow is necessary, be certain that the elbow is installed with a "soft" bend to allow damper blades to operate properly. SECTION 7 Installing Optional Balancing Damper Some kits include an optional balancing damper to allow for adjustment of the system. The damper may be used where the grills will be connected using branches of unequal length or where the flow will need to be balanced for any reason. To Install the optional damper: 1. The damper must be installed on the branch with the least restriction. This is generally the duct that is shortest or has the fewest bends. 2. Drill a 5/16" hole approximately 1-1/2" from the edge on the flat side of the “Y” transition. 3. Insert the shaft of the damper into the hole drilled in step 2. Place the washer, handle, then wing nut onto the shaft (Figure 8). Figure 8 Damper “Y” Transition Hole Wing Nut HandleWasher Shaft Figure 9 Screws Terminal Box 2. Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white) and one hot (black lead connected to the switch). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the terminal box to make the connections to the fan’s pre-wired electrical terminal strip. 3. Insert the white wire from the house into the terminal strip port labeled “N” and tighten using a small regular screwdriver. Insert the black wire from the wall switch into the terminal strip port labeled “L” and tighten using a small regular screwdriver. Since the motor is isolated within a plastic housing, grounding is not necessary (Figure 10). Supply from house Blue Black/RedBrown Red Black White N L Figure 10 4. Adjust the damper to balance airflow and tig...
Эта инструкция также подходит к моделям:Вентиляторы - AIF6Y (184.91 kb)
Вентиляторы - AIK24Y (184.91 kb)
Вентиляторы - AIK26Y (184.91 kb)
Вентиляторы - AIF10X (184.91 kb)