Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Air King, модель AIF4X

Производитель: Air King
Размер: 184.91 kb
Название файла:
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


One neutral (white) and one hot (black lead connected to the switch). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the terminal box to make the connections to the fan’s pre-wired electrical terminal strip. 3. Insert the white wire from the house into the terminal strip port labeled “N” and tighten using a small regular screwdriver. Insert the black wire from the wall switch into the terminal strip port labeled “L” and tighten using a small regular screwdriver. Since the motor is isolated within a plastic housing, grounding is not necessary (Figure 10). Supply from house Blue Black/RedBrown Red Black White N L Figure 10 4. Adjust the damper to balance airflow and tighten the wing nut to secure. SECTION 8 Wiring the Fan CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. 1. Remove the screws securing the terminal box cover plate located on the side of the motor (Figure 9). 4. Check to make sure all wire connections are securely fastened to the terminal strip and replace the fan terminal box cover. 5. Restore power and test your installation. SECTION 9 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. 1. Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Step 2 of Section 4, to reinstall grill. 2. The fan’s bearings are sealed and provided with an internal lubricating material, no additional lubrication is necessary. 5S7635036 New 9-06 4 of 12 Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1b. Wiring is not connected properly. 1c. Motor has stopped operating. 1a. Replace fuse or reset circuit breaker. 1b. Turn off power to unit. Check that all wires are connected. 1c. Replace motor. 2. Fan is operating, but air moves slower than normal. 2a. Obstruction in the exhaust ducting. 2b. Speed control not set high enough. 2c. Incorrect wiring. 2a. Check for any obstructions in the ducting. The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outside. 2b. If a speed control is being used, confirm the setting. 2c. Turn off power to unit. Check that all wires are connected correctly. 3. Fan is operating louder than normal. 3a. Motor is loose. 3b. Fan mounting screws too tight. 3c. Fan damaged in shipping. 3a. Turn off power to unit. Confirm unit is mounted securely to bracket. Restore power to unit. 3b. Turn off power to the unit. L...

Эта инструкция также подходит к моделям:
Вентиляторы - AIF6Y (184.91 kb)
Вентиляторы - AIK24Y (184.91 kb)
Вентиляторы - AIK26Y (184.91 kb)
Вентиляторы - AIF10X (184.91 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории