Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Hunter Fan, модель 41949-01

Производитель: Hunter Fan
Размер: 7.84 mb
Название файла: 41949.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


011_41949_EngS_2-12-08.indd 5 2/12/08 2:43:30 PM A13 Route wires through strain relief. For supply connection, use wires suitable for at least 90. C (194. F). A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper GroundA14 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light Together *Option Connect wires as shown. 0A16HA15F Install the wiring cover plate. Make sure all Connect 4” duct and vent to the outside. Tape joints. wiring connections are inside the box or under If ducting does not fit securely, an adapter may need the wiring cover plate. to be purchased. 41949-01 02/12/2008 011_41949_EngS_2-12-08.indd 6 2/12/08 2:43:33 PM 41949-01 02/12/2008 A19 J Secure the motor by tightening the 2 screws. A20 Turn on the power source. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. 0 A17 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 0 I A18 ON OFF A21 Test the motor. If the motor does not run, check the plug connection. A22 E1 Go to step on page 17 to attach grille. 011_41949_EngS_2-12-08.indd 7 2/12/08 2:43:36 PM 41949-01 02/12/2008 5/8 1/2 5/8 1/2 B12 Slide the mounting rails into brackets. Mark position of screws by using holes as a template. Insert screws, leaving space between the screw head and the joist. Screws are not provided. New Construction – suspended between joists B11 E F 1/8” bit B14 B15 F B13 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Drill a hole in the center of each outline. Attach the rails onto the screws. B16 011_41949_EngS_2-12-08.indd 8 2/12/08 2:43:39 PM 41949-01 02/12/2008 Tighten screws. Route wires through strain relief. For supply connection, use wires suitable for at least 90. C (194. F). Connect wires as shown. B17 B18 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground B19 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option B21 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. H B20 G 011_41949_EngS_2-12-08.indd 9 2/12/08 2:43:42 PM 41949-01 02/12/2008 10 B27 E1 Go to step on page 17 to attach grille. B22 I Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. I B23 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B25 Turn on the power source. ON OFF B26 B24 J Test the motor. If the motor does not run, check the plug connection. Secure the motor by tightening the 2 screws. 011_41949_EngS_2-12-08.indd 10 2/12/08 2:43:46 PM C12EFExisting Construction – accessible from above EXISTING FAN C11 NO EXISTING FAN 9”9.75” ORRemove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (9”x 9.75”). Cut out an opening for the housing. Use the motor housing as a template to mark position. Slide the mounting rails into brackets. position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. 5/81/25/81/2C13 C14 Mark position of screws by using holes as a template. 11 41949-01 02/12/2008 011_41949_EngS_2-12-08.indd 11 2/12/08 2:43:49 PM 41949-01 02/12/2008 12 C17 C18 C19 C20 C15 C16 Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws. Tighten screws. Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Route wires through strain relief. For supply connection, use wires suitable for at least 90. C (194. F). 011_41949_EngS_2-12-08.indd 12 2/12/08 2:43:52 PM 41949-01 02/12/2008 13 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground C22 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option Tighten the strain relief screws. Connect wires as shown. C24 I H C23 G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. C21 011_41949_EngS_2-12-08.indd 13 2/12/08 2:43:55 PM 41949-01 02/12/2008 14 C25 I C26 J C27 ON OFF C28 Secure the motor by tightening the 2 screws. Turn on the power source. Test the motor. If the motor does not run, check the plug connection. C29 E1 Go to step on page 17 to attach grille. Reinstall the motor by inserting the tab...

Эта инструкция также подходит к моделям:
Вентиляторы - 83001 (7.84 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории