Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Panasonic, модель FV-08VKSL2

Производитель: Panasonic
Размер: 871.3 kb
Название файла: f2aadfac-ff44-4053-9d9f-acf1cc865159.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Position : Use for factory test only. Position : Fan stop High/Low delay time preset switch positions Delay Time [min] 0.5 1 2 3 5 10 20 30 60 Factory setting: 20 minutes. Position : Use for factory test only. 5 OPERATION Detectible range The distance that motion can be detected limited to 10 feet(3m). The field of view of the sensor is 90. (Room temperature is 25 C) Motion sensor The low speed is determined low speed air volume preset switch. by The delay time is determined by High/Low delay time preset switch. Fan operates at high speed for adjustable duration of 0.5 to 60 min.after motion is no longer detected. At low speed When motion is detected,fan runs at the high speed. Remains running at high speed until the delay time has passed. Human active Human active Fan active Fan active At low speed When manual wall switch is closed, fan runs at high speed. When manule wall switch is opened, fan remains running at high speed until the delay time haspassed. SPECIFICATIONS Specifications Model No. Air direction Voltage (V) Frequency (Hz) Duct diameter (inches) Noise (sones) Power consumption(W) Speed (rpm) Air deliver at 0.1''WG (CFM) Weight Ib.( )kgFan body Lighting unit Fluorescent lamp Night lamp FV-08VKML2 Exhaust 120 60 4 0.3 12.6 18X2 4 807 80 16.5(7.5) FV-08VKSL2 Exhaust 120 60 4 0.3 12.6 18X2 4 807 80 16.3(7.4) HVI Certified performance based on HVI Procedures 915,916,and 920 Reference specifications Noise (sones) FV-08VKSL2 Exhaust Exhaust 120 60 4 120 60 4 FV-08VKML2 9.6 7.8 6.8 5.9 5.0 1.4 () 9.6 7.8 6.8 5.9 5.0 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 18X2 4 4 4 4 4 4 4 4 4 4 4 4 723 675 661 625 587 723 675 661 625 587 70 60 50 40 30 0 70 60 50 40 30 16.3(7.4) Model No. Air direction Duct diameter (inches) Power consumption(W) Speed Weight (rpm) (CFM) 16.5(7.5) Air deliver at 0.1''WG Fan body Fluorescent lamp Night lamp Lighting unit Ib.()kg0 * 1.4 ()* Voltage (V) Frequency (Hz) Reference performance based on HVI Procedures 915,916,and 920. () Standby wattage. * 6 GENERAL SAFETY INFORMATION 1. Do not install this ventilating fan where interior room temperature may exceed 104 F (40 C). 2. Make sure that the electric service supply voltage is AC 120V, 60Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 4. Always disconnect the power source before working on or near the fan, motor, light fixture or junction box. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig.A. 8. Provide suction parts with proper ventilation. 9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit. Prohibited Prohibited Prohibited Adaptor Prohibited Fig.A 10. This product has a fluorescent lamp that contains mercury.Disposal may be regulated in your community due to environmental considerations.For disposal or recycling information,please contact your local authorities or the Electronics lndustries (Cooking area) Do not install above or Alliance:inside this area CAUTION: 1. For general ventilating use only.Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area.(Fig.B) 3. This product must be properly grounded. Floor Cooking equipment Fig.B WARNING: To reduce the risk of fire,electric shock or injury to persons,observe the following: 1. Use this unit only in the manner intended by the manufacturer.if you have any questions,contact to the manufacturer. 2. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards,including fire-rated construction. 3. Sufficient air is needed for proper combustion and exhaustiong of gases through the flue(chimeny) of fuel burning equipment to prevent back drafting.Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE)and the local code authorities. 4. When cutting or drilling into wall or ceiling,do not damage electrical wiring and other hidden utilities. 5. Ducted fans must always be vented to the outdoors. 6. Do not use this unit with any solid-state control device.Solid state controls may cause harmonic distortion which can cause motor humming noise. 7. Before servicing or cleaning unit,switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally,When the service disconnecting means cannot be locked,securely fasten a prominent warning device,such as a tag,to the service panel. 8. If this unit to be installed over a tub or shower,it must be marked as appropriate for the application and be connected toa GFCI(G...

Эта инструкция также подходит к моделям:
Вентиляторы - FV-08VKML2 (871.3 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории